Electrical Systems Flashcards
How many batteries?
Voltage?
Range?
AH?
Type?
2x
24v DC
Inflight range 27-29v
30 AH each
Lead acid
GPU Voltage
24.5 - 29v to make it ‘avail’
Generator load limits
250A - Ground and above 34,000’
300 - Airborne below 34,000’
PDU (check correct)
Power distribution units. Left, right and centre
EPDU
Emergency power distribution unit. In the nose, front wheel bay
GCU
Generator control units x2. Monitor generator output for V and load limits. Will disconnect gen if out of limits
When is Shed Bus available?
GPU or both generators in flight.
EBC 1 and 2 usual positions
1 - NC
2 - NO
What % N2 does a gen become available?
44% N2
Which bus bars is Gen 1 attached to?
DC Bus 1 - Emerg Bus - Hot Batt Bus
Which bus bars is Gen 2 attached to?
DC Bus 2 - DC Bus 2 - Central Bus - Hot Batt Bus
|
Shed bus
‘Elec XFR Fail’
Batteries powering DC Bus 1+2 during double gen failure.
Press elec emerg switch (guarded)
Cas message for - Batteries powering DC Bus 1+2 during double gen failure.
‘Elec XFR Fail’
Purpose of EC BCK 2
Keeps BC2 closed so that is can activate SC1/2 in case of flame out
When batteries are normal what is their range? What colour will this be?
27-29v
Green