Electrical Flashcards

This flashcard deck was created using Flashcardlet's card creator

0
Q

IDG FAULT light

A

Hot temp

Lo oil pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
1
Q

What does ALT ESS XFER Light on mean

A

Not receiving power from AC Bus (it’s normal source)

When Bus 2 is supplying power to the essential bus

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Priority of power AC BUS 1

What is the bus priority system

A

Onside Gen, APU, Offside, Ground power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Utility bus gets its power from

A

It’s respective

AC BUS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What are the 6 AC buses

A
AC BUS 1
AC BUS 2
AC ESS
AC SERV
AC UTIL BUS 1
AC UTIL BUS 2
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What buses powered when AC external power is connected

A

Utility and Service Buses

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What does AC bus 1 power

A

AC ESS BUSS
AC UTIL BUS1
If AC BUS 1 gone then ESS transfers to AC BUS 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What other uses does AC BUS 2 supply power to

A

AC SERV BUS

AC UTIL BUS 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Total power AC power loss

A

ESS BUS is powered from the ADG BUS and the ADG.

The ESS BUSS powers the ESS TRU which powers the DC ESS BUSS and the BATT BUSS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What does the AC service bus power

A

• Powers the service outlets that are used for cleaning
• Powers the service TRU with powers the DC SERVICE
BUS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Where do the AC UTIL BUS 1 and 2 receive their power and what do they power

A
  • Powered by their respective AC BUS and 2

* UTIL BUS 1 and 2 provide power to the battery chargers and galley

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

When are utility buses shed

A

During flight when only one gen in use

• On the ground when one gen operating and flaps down, and main and service door closed

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Service configuration

A
  • UTIL BUSS 1 and 2 powered

* Battery chargers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When does ADG deploy

A

• Loss of all Generators and

AC BUS 1 or 2 not powered

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Sources of DC power

A

5 TRUs
2 NiCad batteries (24 volt 17amp Main) (24 volt 43 amp APU)
DC external power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

What are the 5 TRUs

A
  • TRU 1
  • TRU 2
  • ESS TRU 1
  • ESS TRU 2
  • SERV TRU
16
Q

What is the purpose of the TIE 1 and TIE 2 switch lights

A

To select the associated DC ties to closed. White switch and EICAS indicates closing of the tie

17
Q

ESS tie switch light

A

Connects the SERV TRU to the ESS BUS

18
Q

Batteries

What charges them

A

APU-24 volt 43 Ampere
Main Battery-24 volt 17 Ampere
UTIL BUS 1 and 2

19
Q

What does the DC service bus power?

A

Nav, Lav, Dome, service

Powered from APU Battery

20
Q

What’s on the emergency Bus?

A

Squibs
Fuel SOV
Hyd SOV

21
Q

What powers emergency bus

A

APU battery bus and Left battery bus

22
Q

Voltage, hertz, kVA of ADG

A

115 volts, 400htz, 15 kVA

23
Q

IDG , APU Gen

A

115 volt, 400 Hz, 30 kVA