How many generators (including APU) are needed to power all electrical needs?

A

1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

In flight, during generator failure, what is automatically shed?

A

Main galley power

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

When RAT deploys, what does it power?

A

AC and DC ESS BUS and SHED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

In an emergency what does BATT 1 power?

A

AC ESS BUS through inverter

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

In an emergency what does BATT 2 power?

A

DC ESS BUS

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What are the electrical priorities?

A

G enerators
E xternal Power
A pu generator
R am air turbine
B atteries

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What are the capacities of the generators and the APU?

A

90 KVA
3 phase
115-200 V
400 Hz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What are the capacities of the emergency generator?

A

5 KVA
3 phase
115-200 V
400 Hz

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What do the (TR) transformer-rectifiers do?

A

Convert AC to DC

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When will you see a green arrow connected to the battery?

A

only when current is >1 amp

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What are the limitations for the IDG FAULT buttons?

A

Do not depress more than 3 seconds.
Engine must be running or windmilling
Can be reset on ground only

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

When will you get the IDG FAULT light on?

A

High IDG oil temp

Low IDG oil pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

When will the batteries start charging?

A

<26.5V

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

When will the battery contactors close?

A

AC BUS 1&2 not powered by other sources (no EMER GEN during flight, worst case)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

When will the auto batt cut-off?

A

Ground
BAT in AUTO
AC power source N/A
Batt voltage low
(reset by cycling BAT buttons)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

How long are batteries prevented from charging after APU start?

A

30 minutes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

During preflight, what white lights should be present on the ELEC panel?

A

None!

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

When you turn on the battery what is the max charging current allowed?

A

<60A and decreasing within 10 seconds

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What tells you that the APU is powering the AC?

A

AVAIL light on the APU START button AND AVAIL light on the EXT POWER button

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

When you start engine 2, what happens to the bus tie?

A

Opens, APU now powers BUS 1 and Generator powers BUS 2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

RAT & EMER GEN FAULT light is on, what does this mean?

A

The RAT takes 8 seconds to spool up before coming on-line, during this time you are running off the batteries.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

What is the min speed for the RAT to function?

A

140kts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

During landing, at what speed does the EMER GEN become unavailable?

A

125kts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

What happens below 50kts during total electrical failure?

A

All displays blank
Braking and engine control
VHF1
NO nosewheel steering

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Which cockpit lighting is available during an emergency electrical situation?

A

Right side dome light, main panel flood lights (left two columns only) and the standby compass light.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

What is the function of the static inverter?

A

A static inverter transforms DC power from Battery 1 into one KVA of single-phase 115v/400hz AC power which is then supplied to part of the AC essential bus.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

How many types of circuit breakers has the aircraft?

A

The aircraft has two types of C/Bs. Monitored (green): When off for more than one minute the C/B TRIPPED warning is triggered on the ECAM. Non-monitored (black).

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Can you reconnect an IDG in flight?

A

No

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
29
Q

AC Power (115v) can be provided by which power sources?

A

Two engine generators one APU generator and one external power source.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
30
Q

What is the order of priority for the different generators?

A

Engines
external power
APU

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
31
Q

If the battery voltages are below the minimum how do you charge them?

A

I have to check that the BAT pushbuttons are on and switch the external power on.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
32
Q

When does the RAT automatically deploy?

A

Electrical power to both AC BUS #1 & #2 is lost and the aircraft speed is above 100 knots.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
33
Q

Is it possible to connect the engine driven generators in parallel?

A

No.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
34
Q

What does the blue EXT PWR ON light mean?

A

External power is supplying the aircraft electrical systems.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
35
Q

After IDG disconnection why do you get a GALLEY SHED indication in the SD?

A

It is a reminder that the main galley has been shed automatically following the loss of one generator.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
36
Q

If both engine generators are powering the system and one subsequently fails are any busses unpowered?

A

No but some loads are shed in both main galleys.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
37
Q

What is the purpose of the Ground and Auxiliary Control Power Unit (GAPCU)?

A

The GAPCU controls the frequency and voltage of the APU generator / external power output protects the network by controlling the external power contactor and the APU generator line contactor.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
38
Q

Where is the ground power connector?

A

The ground power connector is near to the nosewheel on the right side of the fuselage.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
39
Q

What occurs in case of a TR fault?

A

The contactor of each TR opens automatically in case of overheat or minimum current. The other TR automatically replaces the faulty one. The ESS TR supplies the DC ESS BUS.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
40
Q

Having started the APU with external power connected how can you get the APU generator to power the electrical system?

A

By pushing the EXT PWR Pb thus disconnecting the external power.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
41
Q

What powers the emergency generator?

A

The blue hydraulic via the RAT.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
42
Q

You enter a dark cockpit what action is necessary before checking the battery voltages?

A

You have to check that both batteries are off.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
43
Q

What is the purpose of the Transformer Rectifiers (TR’s)?

A

Two main Transformer Rectifiers TR 1 and TR 2 supply the aircrafts electrical system with up to 200 amperes of DC current. A third identical TR the ESS TR can power the essential DC circuit from the emergency generator if the engine and APU generators all fail or if TR 1 or TR 2 fails.

44
Q

What are the main functions of the Generator Control Unit (GCU)?

A

Controls the frequency and voltage of the generator output and protect the network by controlling the associated generator line contactor (GLC).

45
Q

Which bus supplies the AC ESS BUS?

A

The AC ESS BUS is normally supplied from the AC BUS 1 it may be supplied be AC BUS 2 through the AS ESS FEED pb.

46
Q

What is the capacity of the main batteries?

A

Two main batteries have a capacity of 23 ampere-hours each.

47
Q
BAT 1 (2) pb
(ELEC Panel)
  • Auto
  • OFF
  • FAULT Light
A

Auto:The battery charge limiter automatically closes/opens the corresponding battery line contactor. The batteries are connected to the DC BAT BUS in the following cases:
* APU starting until N < 95%. (limited to 3 min when the emergency generator is running)
* Battery voltage < 26.5 V (battery charge).
* Loss of AC BUS 1&2 when below 100 knots (EMER GEN not supplying).
OFF:The battery charge limiter is not operating: the battery line contactor is open.
FAULT Light:The charging current for the corresponding battery is outside limits. In this case the battery contactor opens.

48
Q
IDG 1 (2) pb (guarded)
(ELEC Panel)
  • FAULT Light
A

Switch spring loaded out. Do not hold > 3 sec. Do not disconnect when engine not windmilling.
FAULT Light:
- IDG oil outlet overheats (above 185°C), or
- IDG oil pressure is low (inhibited at low engine speed: N2 below 14 %)
LT extinguishes when the IDG is disconnected.

49
Q
GEN 1 (2) pb
(ELEC Panel)
  • ON
  • OFF
  • FAULT Light
A

ON: Generator line contactor closes if electrical parameters are normal.
OFF: Generator line contactors open. The fault circuit is reset.
FAULT Light:
- The generator control unit (GCU) trips it.
- Line Contactor open with the GEN pb selected ON.

50
Q
APU GEN pb
(ELEC Panel)
- ON
- OFF
- FAULT Light
A

ON:Line contactor closes if parameters are normal and the EXT PWR line contactor is open.
OFF: Line contactor opens. The fault circuit is reset.
FAULT LT:
- The generator control unit (GCU) trips it.
- Opening of the line contactor (except if the APU GEN pb is selected OFF). The light is inhibited when APU speed is too low or if the APU GEN line contactor opens after EXT PWR or ENG GEN takes over.

51
Q

BUS TIE pb
(ELEC Panel)

  • AUTO
  • OFF
A

AUTO:The bus tie contactors (BTCs) open or close automatically.
OFF:Both bus tie contactors open.

52
Q

AC ESS FEED pb
(ELEC Panel)

  • NORMAL
  • ALTN
  • FAULT Light
A

NORMAL:The AC ESS BUS is supplied from AC BUS 1. It is automatically supplied by AC BUS 2, when AC BUS 1 is lost.
ALTN:Comes on when manually selected. The AC ESS BUS is supplied from AC BUS 2.
FAULT LT:AC ESS BUS is not supplied.

53
Q

GALY & CAB pb
(ELEC Panel)

  • AUTO
  • OFF
  • FAULT Light
A

AUTO: Main galley, secondary galley and in-seat power supply are supplied. The main galley and in-seat power supply are shed automatically when:
- In flight: only one generator is operating.
- On the ground: only one engine generator is operating. (Except APU or EXT power.)
OFF:The main galley, secondary galley and in-seat power supply are not supplied.
FAULT LT: When the load on any generator is more than 100% of rated output.

54
Q

EXT PWR pb
(ELEC Panel)

  • AVAIL Light
  • ON Light
A

AVAIL light comes on green if:
- External power is plugged in, and
- External power parameters are normal.
Pressed momentarily: Opens/Closes the external power line contactor. The ON light comes on blue when closed.

55
Q

COMMERCIAL pb
(ELEC Panel)

  • ON
  • OFF
A

ON: All aircraft commercial electrical loads are supplied:
- Cabin and cargo lights
- Water and toilet system
- Drain mast ice protection
- Galley
- Passengers’ entertainment
- Semi-automatic cargo loading (if installed)
OFF: Switches off all aircraft commercial electrical loads.

56
Q

MAN ON pb (guarded)
(EMER ELEC PWR panel)

  • AUTO
  • Pressed
A

AUTO: RAT deploys when- AC BUS 1&2 is not electrically supplied and speed >100 knots.
Pressed: Manual RAT extension.

57
Q

RAT EMER GEN
(EMER ELEC PWR panel)

  • FAULT Light
A

FAULT LT:This light comes on red if the emergency generator is not supplying power when AC BUS 1&2 are not powered.

58
Q

EMER GEN TEST pb (guarded)
(EMER ELEC PWR panel)

  • Pressed and held
A

Pressed and held:
* If AC NORMAL BUSES are supplied:
- The EMER GEN is driven hydraulically if the blue electric pump is running. The AC ESS BUS and the DC ESS BUS are connected to the emergency generator. (The DC ESS SHED and AC ESS SHED buses are not powered.)
- ECAM displays the ELEC page automatically (only on the ground).
* If only the batteries supply the aircraft:
- The static inverter powers the AC ESS BUS.

59
Q

GEN 1 LINE
(EMER ELEC PWR panel)
- OFF
- SMOKE LT

A

OFF: GEN 1 line contactor opens. AC BUS 1 is supplied from GEN 2 through bus tie contactors. This is used for the avionics smoke condition to isolate GEN 1, but it continues to power one fuel pump in each wing tank.
Smoke LT: Avionics smoke.

60
Q

What powers the emergency generator?

A

Blue Hydraulic power from the RAT

61
Q

What is the power source for the FADEC?

A
  • The system has its own alternator making it independent of the aircraft electrical system when N2 is above a set value
  • If this alternator fails, the FADEC automatically switches to aircraft electrical power
62
Q

What is the purpose of the static inverter?

A

To provide AC power to the AC ESS bus from the battery when the EMG GEN is not online when in Emergency Electrical configuration.

63
Q

What is the priority sequence for electrical power?

A
  • Generators (ENG)
  • EXT PWR (Manually selected)
  • APU Gen
  • RAT Emer Gen
  • Batteries
64
Q

When performing the PRELIMINARY FLIGHT DECK PREPARATION, what is the minimum battery voltage?

A

25.5 Volts

65
Q

What do you do if it is below 25.5V?

A

Select battery switches ON with EXT PWR on aircraft

66
Q

Will the batteries completely drain if you leave the BAT switches in AUTO after AC power is removed?

A

No. Battery cut-off logic prevents complete discharge when the aircraft is on the ground and un-powered - 22 VDC

67
Q

How is the BATTERY BUS normally powered?

A

DC BUS 1 through a DC tie contactor

68
Q

When is the battery check performed?

A

During the FLIGHT DECK PREPARATION check of the ELEC Panel

69
Q

What does a Bat Fault light indicate?

A

Battery charging current is outside limits (BAT contactor opens)

70
Q

What are the 3 times the batteries are connected to the BATTERY BUS?

A
  • APU Start- Battery charging- AC BUS 1&2 not powered and airspeed below 100 knots
71
Q

What does the ON BAT light indicate?

A

It is illuminated amber if one or more IRs is supplied by the aircraft battery. Also illuminates briefly during the beginning of a full alignment.

72
Q

How long will each ADIRU stay on battery power?

A

ADIRS 2&3 will remain on battery power for 5 minutes to hold alignment until a generator can be restored.
ADIRU 1 (ADIRU 3 if captain selected ATT HDG CAPT 3) will remain on battery power until generator power is restored or the batteries fail.

73
Q

When performing the FLIGHT DECK PREPARATION, what are we looking for on the ELEC panel BAT check?

A
  • ECAM ELEC page - select- Bat 1&2 - OFF then ON- Check BATT charge current is < 60 amps and decreasing within 10 seconds
74
Q

What does each of the DMCs normally supply?

A
  • DMC1: Capt PFD, ND, Upper ECAM DU
  • DMC2: F/O PFD, ND, Lower ECAM DU
  • DMC3: Backup
75
Q

How is the IDG (Integrated Drive Generator) cooled?

A

By fuel from the HP fuel pump drawn in from the fuel manifold and then returned to its respective outer tank. When full, the outer tank spills over to the inner tank.

76
Q

If the IDG return fuel fills the wing tanks, what occurs?

A

The center tank pumps turn off until the wing tank quantity reduces by 1100 lbs

77
Q

With full wing fuel what prevents the IDG fuel from overfilling the wings?

A

Separate full level switches

78
Q

What does IDG stand for?

A

Integrated Drive Generator

79
Q

What is the function of the IDG?

A

Converts variable engine speed to constant speed for optimum generator operation

80
Q

What does an IDG FAULT light indicate?

A
  • Oil pressure low (inhibited when N2 <14- Oil outlet temperature overheat- Light is inhibited when IDG is disconnected
81
Q

What precautions must you take when disconnecting an IDG?

A
  • Do not disconnect when engine is not operating or windmilling- Do not hold button longer than 3 seconds
82
Q

How can an IDG be reset?

A

On the ground by maintenance

83
Q

What is the max continuous load rating of the engine and APU generators?

A

90 kVA

84
Q

What does the APU GEN FAULT light indicate?

A

The generator line contactor is open because of a fault detected by the GCU

85
Q

When is the APU GEN FAULT light inhibited?

A
  • APU speed to low- Line contactor OPEN after EXT PWR or ENG GEN takes over
86
Q

What is the function of the BUS TIE in the AUTO position?

A

Allows the BUS TIE CONTACTORS to open and close automatically to maintain power to both AC BUS 1&2:
- Allows a single source to power the entire system
- Allows connection of the APU GEN or EXT PWR to the system
- Inhibits multiple sources to connect simultaneously

87
Q

How does the GALLEY pushbutton work in AUTO?

A

Sheds main galley and in-seat power supply if:- Only 1 generator (APU or ENG) is available in FLIGHT, OR- Only 1 ENG generator is available on the ground

88
Q

What is the function of the AC ESS FEED pushbutton in the normal position?

A

Allow AC BUS 1 to power the AC ESS BUS

89
Q

How is AC ESS FEED transferred from AC BUS 1 to AC BUS 2?

A

Automatically or Manually by selecting ALTN on the AC ESS FEED pushbutton

90
Q

What does the AC ESS FEED pushbutton white ALTN light indicate?

A

AC BUS 2 is powering the AC ESS BUS

91
Q

What lights illuminate when the DC ESS SHED BUS fails?

A
  • Floor proximity emergency escape path marking system- Overhead emergency lighting- EXIT signs
92
Q

What buses are powered by the emergency generator?

A
  • AC ESS and AC SHED- DC ESS and DC SHED
93
Q

What does the RAT & EMER GEN red fault light indicate?

A
  • Loss of AC BUS 1 & 2,- Airspeed above 100 Kts, and- Emergency generator not supplying AC power
94
Q

What is the function of the RAT & EMER GEN pushbutton?

A
  • AUTO- RAT will automatically extend if AC BUS 1 & 2 are not powered and airspeed is >100 Kts
  • MAN- Extend the RAT at any time
95
Q

What happens when you push the GEN 1 LINE pushbutton?

A
  • GEN 1 Line Contactor opens and the white OFF light illuminates
  • AC BUS 1 is powered by GEN 2 through the BUS TIE CONTACTOR
  • GEN 1 continues to power 1 fuel pump in each wing tank
96
Q

What does the amber “FAULT” light in the GALLEY pushbutton indicate?

A

At least 1 generator load is above 100% rated output

97
Q

What does a “FAULT” on the ENG GEN pushbutton indicate?

A
  • A Fault is detected by the GCU:
  • Overload
  • Over/under voltage
  • Differential fault (short) And/or:
  • The generator line contactor is open
98
Q

When is it normal to see the ENG GEN FAULT light illuminated?

A

Prior to engine start because the GEN is selected ON but the line contactor is open - normal condition

99
Q

What does the red “FAULT” light on the RAT & EMER GEN push button indicate?

A

Normal AC is lost and the emergency generator is not supplying power

100
Q

When should the red “FAULT” light on the RAT & EMER GEN pushbutton be expected?

A

During the 8 seconds RAT deployment and power up

101
Q

What is the output of the Emergency Generator?

A

5 kVA

102
Q

Do pilots ever use the EMER GEN TEST pushbutton?

A

No. Maintenance function only

103
Q

When would you select the GEN 1 LINE pushbutton?

A

Smoke procedures

104
Q

How long will it take to charge the batteries?

A

20 minutes

105
Q

What is the output of the static inverter?

A

1 kVA

106
Q

Is there another way to deploy the RAT?

A

Yes, RAT MAN ON from the HYD panel