COMPEX Ex p Inspection Flashcards

1
Q

TABLE 3 Ex p

A.1
EQUIPMENT IS APPROPRIATE TO THE EPL / ZONE REQUIREMENTS OF THE LOCATION

A

DETAILED
CLOSE
VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

TABLE 3 Ex p

A.2
EQUIPMENT GROUP IS CORRECT

A

DETAILED

CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

TABLE 3 Ex p

A.3
EQUIPMENT TEMPERATURE CLASS IS SURFACE TEMPERATURE IS CORRECT

A

DETAILED

CLOSE

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

TABLE 3 Ex p

A.4
EQUIPMENT CIRCUIT IDENTIFICATION IS CORRECT

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

TABLE 3 Ex p

A.5
EQUIPMENT CIRCUIT IDENTIFICATION IS AVAILABLE

A

DETAILED
CLOSE
VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

TABLE 3 Ex p

A.8
ENCLOSURE, GLASS PARTS AND GLASS TO METAL SEALING GASKETS AND / OR COMPOUNDS ARE SATISFACTORY.

A

DETAILED
CLOSE
VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

TABLE 3 Ex p

A.7
THERE ARE NO UNAUTHORISED MODIFICATIONS

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

TABLE 3 Ex p

A.8
THERE IS NO EVIDENCE OF UNAUTHORISED MODIFICATIONS

A

CLOSE

VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

TABLE 3 Ex p

A.9
LAMP RATING, TYPE AND POSITION ARE CORRECT

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

TABLE 3 Ex p

B.1
TYPE OF CABLE IS APPROPRIATE

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

TABLE 3 Ex p

B.2
THERE IS NO OBVIOUS SIGNS OF DAMAGE TO CABLES.

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

TABLE 3 Ex p

B.3
EARTHING CONNECTIONS, INCLUDING ANY SUPPLEMENTARY EARTHING BONDING CONNECTIONS ARE SATISFACTORY (CONNECTIONS ARE CLEAN AND TIGHT AND CONDUCTORS ARE OF SUFFICIENT CROSS-SECTION) - PHYSICAL CHECK

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

TABLE 3 Ex p

B.3
EARTHING CONNECTIONS, INCLUDING ANY SUPPLEMENTARY EARTHING BONDING CONNECTIONS ARE SATISFACTORY (CONNECTIONS ARE CLEAN AND TIGHT AND CONDUCTORS ARE OF SUFFICIENT CROSS-SECTION) - VISUAL CHECK

A

CLOSE

VISUAL

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

TABLE 3 Ex p

B.4
FAULT LOOP IMPEDANCE (TN SYSTEMS) OR EARTHING RESISTANCE (IT SYSTEMS) IS SATISFACTORY.

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

TABLE 3 Ex p

B.5
AUTOMATIC ELECTRICAL PROTECTIVE DEVICES OPERATE WITHIN PERMITTED LIMITS.

A

DETAILED

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

TABLE 3 Ex p

B.6
AUTOMATIC ELECTRICAL PROTECTIVE DEVICES ARE SET CORRECTLY

A

DETAILTED

17
Q

TABLE 3 Ex p

B.7
PROTECTIVE GAS INLET TEMPERATURE IS BELOW MAXIMUM SPECIFIED

A

DETAILED

18
Q

TABLE 3 Ex p

B.8
DUCTS, PIPES AND ENCLOSURES ARE IN GOOD CONDITION

A

DETAILED
CLOSE
VISUAL

19
Q

TABLE 3 Ex p

B.9
PROTECTIVE GAS IS SUBSTANTIALLY FREE FROM CONTAINMENTS

A

DETAILED
CLOSE
VISUAL

20
Q

TABLE 3 Ex p

B.10
PROTECTIVE GAS PRESSURE AND / OR FLOW IS ADEQUATE

A

DETAILED
CLOSE
VISUAL

21
Q

TABLE 3 Ex p

B.11
PRESSURE AND / OR FLOW INDICATORS, ALARMS AND INTERLOCKS FUNCTION CORRECTLY

A

DETAILED

22
Q

TABLE 3 Ex p

B.12
CONDITION OF SPARK AND PARTICLE BARRIERS OF DUCTS FOR EXHAUSTING THE GAS IN HAZARDOUS AREA ARE SATISFACTORY.

A

DETAILED

23
Q

TABLE 3 Ex p

B.13
SPECIFIC CONDITIONS OF USE (IF APPLICABLE) ARE COMPLIED WITH

A

DETAILED

24
Q

TABLE 3 Ex p

C.1
EQUIPMENT IS ADEQUATELY PROTECTED AGAINST CORROSION, WEATHER, VIBRATION AND OTHER ADVERSE FACTORS

A

DETAILED
CLOSE
VISUAL

25
Q

TABLE 3 Ex p

C.2
NO UNDUE ACCUMULATION OF DUST AND DIRT

A

DETAILED
CLOSE
VISUAL

26
Q

ATEX Inspection Report should include the following

A
Date
Name
Grade of Inspection
Type of Inspection
Tag Name 
Description of Item
Manufacturer
Model number.
Circuit Reference.
Protection Type.
Gas Group of Item
Gas Group of Area
EPL
Temperature Class
ATEX Certificate Number.

Description of Defect
Table Check Number (IEC 60079-17)

Defect contravenes
Equipment Certification
The Standard (IEC 60079-14)
Environmental Issue

Item to be repaired?
Item to be replaced?
Remedial Action Required?
Remedial date for Completion?