Commercial Circuit Venting Flashcards

1
Q

Define a basic circuit vent

A

Requires two vents. A circuit vent attached to the trap arm of the most upstream fixture and a relief vent connected below the most down stream fixture

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Define additional circuit vent

A

A vent pipe that is installed between a circuit vent and a relief vent to provide additional air circulation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Define relief vent

A

Vent pipe that is used in conjunction with a circuit vent to provide additional air circulation between a drainage system and venting system

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What would be required on a circuit vent if the soil or waste deck or building drain or branch is discharging more than six fixture units past the circuit vented branch

A

A relief vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What do you need when they’re more than eight fixtures between a circuit vent and the relief vent

A

Additional circuit vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

In a circuit vent, what do you need whenever a circuit vented branch changes direction by more than 45°?

A

Additional circuit vent in between that offset or change of direction

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What is the minimum size of an additional circuit vent or relief vent installed in conjunction with a circuit vent?

A

Permitted to be one size smaller than the required size of a circuit vent, but need not to be larger than 2 inches

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

When can the horizontal branch be circuit vented

A

If the circuit vent is connected to the trap arm of the most upstream fixture, all fixtures on the branch are on the same story and no stacks drain into the branch upstream of any of the circumvented fixtures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Went to circuit vented branches are symmetrically connected to a branch or stack by the use of a double Y or T what can that serve as?

A

Combined relief vent

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When can an additional circuit vent have one or two trap arms draining into a vertical section of it

A

Can have one, but if two That they are connected symmetrically and no more than one and a half fixture units each

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Where does the developed length start when sizing a circuit vent?

A

From where connects to the horizontal circuit vented branch to prevent stack stack vent or vent sitter or outside air

How well did you know this?
1
Not at all
2
3
4
5
Perfectly