Based on HYP Assignment 56
Means of Egresss Sizing for Stairway what is the factor you multiply by and by what? And can not be less than _____inches between handrails.
Egress sizing is based on (occupant load) x
0.3 (factor)
IBC 1005.3.1
____48__inches minimum between handrails, so if the calculation is less than 48inches you must use 48inches.
IBC 1009..3.2
What are exceptions to egress sizing of stairways?
If a building is equipped with automatic sprinklers you can use factor 0.2
What is the sizing factor for other components of egress factor?
0.2 per occupant
What is the minimum width of exit access stairways?
48inches minimum between handrails
Doors what is the max amount of encroachment into halLway
Doors, when fully opened, shall not reduce the required width by more than 7inches, doors in any positions shall not reduce the required width by more than one-half
(IBC 1005.7.1)
Egress sizing factor can be reduced by a factor of [ ] inches if there is [ ]
Egress sizing factor can be reduced by of [0.15 inches per occupant load ]
if there is [automatic sprinklers]
Handrail projects and what is the total of the handrail itself can be
Handrails not permited to project more than 4 1/2”
need to be 1 1/2” from the wall
diameter of actual handrails must be between 1 1/4” - 2” max.
What is the minimum ceiling height at a means of egress?
7’ - 6”