Code Exit Doors and Distances Flashcards

Based on HYP Assignment 56

1
Q

Means of Egresss Sizing for Stairway what is the factor you multiply by and by what? And can not be less than _____inches between handrails.

A

Egress sizing is based on (occupant load) x
0.3 (factor)
IBC 1005.3.1
____48__inches minimum between handrails, so if the calculation is less than 48inches you must use 48inches.
IBC 1009..3.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What are exceptions to egress sizing of stairways?

A

If a building is equipped with automatic sprinklers you can use factor 0.2

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the sizing factor for other components of egress factor?

A

0.2 per occupant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What is the minimum width of exit access stairways?

A

48inches minimum between handrails

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Doors what is the max amount of encroachment into halLway

A

Doors, when fully opened, shall not reduce the required width by more than 7inches, doors in any positions shall not reduce the required width by more than one-half
(IBC 1005.7.1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Egress sizing factor can be reduced by a factor of [ ] inches if there is [ ]

A

Egress sizing factor can be reduced by of [0.15 inches per occupant load ]
if there is [automatic sprinklers]

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Handrail projects and what is the total of the handrail itself can be

A

Handrails not permited to project more than 4 1/2”
need to be 1 1/2” from the wall

diameter of actual handrails must be between 1 1/4” - 2” max.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What is the minimum ceiling height at a means of egress?

A

7’ - 6”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly