Checklists/Flows/Memory Flashcards
What emergency equipment should be in the flight deck?
PBE Halon fire extinguisher Crash Axe Flashlights Life Vests Circuit Breakers Escape ropes Gear and rat pins Observer: Seat/O2/Headset
What are we looking for during the “Maintenance Status” check?
Ensure the status of the aircraft will not prevent power being applied.
How long is IESS(clock) alignment?
90 seconds to align. Not moving.
EICAS messages: Fire detection/extinguishing messages
Eng 1 Fire Eng 2 Fire APU Fire CRG fwd smoke CRG aft smoke 2-ITT Fire Indications
Fire Detection - Lights 6
Eng 1/2 fire ext handles APU EMER STOP CRG fwd/aft extinguish APU fire extinguish 2 master warning lights
Fire detection: Aural warnings
Fire Bell
Master warning Aural
Engine Fire protection is monitored how?
By two detector loops
What do the fire handles command once pulled?
Fuel shutoff valve
Hydraulic shutoff valve
Bleed Air shutoff valve
*Additionally the bleed air xbleed valve is closed
The APU fire detection system is comprised of what?
2 detector loops
The APU fire extinguishing system is comprised of?
One pushbutton
One fire extinguisher
How many seconds does it take on start up for EICAS messages to be displayed?
30 Seconds
A battery showing at 22.5 v guarantees how much power/usage?
Guarantees 10 mins and 2 APU starts
What does pressing the APU EMER STOP button do?
Closes the APU fuel SOV
SHuts down the APU
Lights up the APU fire extinguisher button
APU Fire protection by the FADEC (Full Authority Digital Electronic Control unit does what.
Anytime: 1 minute after fire detection APU extinguisher bottle will light up even if APU EMER STOP hasn’t been pushed
Ground: 10 seconds after fire detection, the APU will automatically shutdown
FADEC will shutdown APU for what scenarios?
UFO/SHELF
Inflight or Ground: On the ground
Underspeed Sensor fail
Fadec Fault High oil temp
Overspeed EGT oil temp
Low oil pressure
Fire