Chapter 4 Flashcards

1
Q

Stairs that are not part of means of egress are often to referred to as What?
Typically these stairs are open and connect only two levels per code limitations

A

Convenience Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Prefabricated Stairs can be made using lightweight materials and techniques. what is a know hazard to fire fighters with these kind of stairs,

A

that when a metal gusset fails or any part of the assembly fails the whole stair assembly is compromised

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What Stairs Have an intermediate landing between floors and reverse directions at that point

A

Return Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What stairs are two separate sets of stairs constructed in a common shaft Scissor stairs

A

Scissor stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Buildings that often include scissor stairs are (4)

A

Airport terminals

Convention centers

Malls

Cinema complexes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What set of stairs are found as grand stairs or convenience stairs serving only two levels, with the minimum width of the run is usually 10 inches

A

Circular Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What set of stairs consist of a series of steps spiraling around a single column to fit in a very small space, each tread is tapered and connects to the column at the treads narrow end

A

Spiral Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What set of stairs are actually ladders used to provide access to an attic space that dose not have permanent access to it

A

Folding Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Common hazard with Folding stairs that firefighters should know

A

That the springs of the folding stairs lose tension rapidly when exposed to heat and also
gas springs that replace springs in the folding stairs can fail with explosive force when exposed to fire temperatures

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

When some buildings use fixed ladders also know as ships ladder in similar applications to provide access a to what areas of the building including

A

Mechanical spaces
Roof hatches at the top of stairways
Between roof levels with portions at different elevations

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

what are stairs called that must resist the effects of products of combustion

A

Protected stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Exit stairs as means of egress features (3)

A

Fire Resistance rating of the enclosure

Separation when exterior stairs are utilized

Features to ensure safety during both non emergency and emergency use

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

4 measures indicated in building code to protect stair enclosures include

A

Limited penetrations in the enclosure for light fire protections and environmental control

Required self or automatic closing fire rated doors

Separation from the rest of the building

Stairway vestibules

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

What set of stairs are naturally ventilated on one or more sides and when fully enclosed are subjected to the same regulations as enclosed stairs

A

Exterior Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Building codes have traditionally required A minimum of one of “what kind of stairs” for serving buildings with five stories or more and more recently codes also require protection for stairs serving floor levels more than 30 feel below the level of exit discharge

A

Smokeproof stair enclosure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What kind of fire protection Uses moving mechanical or electric parts that work as a system and require a power source for operation

A

Active fire protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

What kind of fire Protection Dose not require any system activation or movement it relies on building construction and materials to contain fire or products of combustion

A

Passive Fire Protection

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

In high rise structures codes require what kind of dedicated stairways designed solely to provide firefighters a safe route to access and attack a fire

A

Pressurized stairways

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

What type of enclosures is used to protect the stairway enclosure and provide a means of smoke ventilation before the smoke enters the stair enclosure

A

Passive Smokeproof enclosure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

When a building code allows the use of what kind of stairs when they only connect no more than two adjacent floors above the basement level

A

Open Stairs

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

3 Features protecting conveyor systems that penetrate fire barriers are

A

Fire doors

Shutters

Water spray fixed fire suppression systems

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

Escalator speeds are standardized at

A

100 Feet per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Older Escalator speeds are

A

90 to 120 feet per minute

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

2 of the most common protection for vertical openings for escalators that serve more then two floors are

A

Draft stops 18in deep

Closely paced sprinklers

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
What are three applications that some elevators are now used for
Dedicated elevator cars for firefighter use Designated means of emergency egress in high rise structures Emergency evacuations of individuals with disabilities when properly designed
26
when an elevator meets the necessary qualifications it may be sued during a emergency response what should fire fighters do when using such elevator
Should recall the elevator to the lobby and open the door from a from a floor level above the recalled elevator to check the shaft for smoke infiltration
27
What are three types of elevators
Passenger elevators that carry passengers Freight elevator that carry resources that may be bulky or heavy Service elevators are passenger elevators designed to also carry freight
28
What kind of elevator uses a fluid forced, under pressure into a cylinder containing a piston or Ram
Hydraulic elevator
29
Historically what is the practical upper limit for hydraulic elevators
is about six stories
30
What are four common styles of elevators
Drum elevators, intended for passenger use Traction elevators intended for passenger use Machine Room-less (MRL) elevators intended for passenger use Dumbwaiters intended for cargo use
31
What style of electric elevator use a hoisting cable wound on a drum located in a motor room directly over the hoistway
Drum Elevator
32
What style of electric elevator is used in buildings over six stories
Traction Elevators
33
Traction elevators with ac motors brakes are
aid directly in stopping the car at the correct floor
34
Traction elevator with dc motors brakes are
do not play any part in actually stopping the elevator car
35
Elevator hoistway enclosures usually require to be
Fire rated assembly with 1 or 2 hour rating
36
In hoistways what should not be allowed to run through it unless its required for the elevator itself
Wiring, Ductwork or piping
37
When used for a means of egress an elevator's shaft must be equipped with what
Safety lights and fire ratings suitable to the height of the structure
38
Where more then one hoistway is provided how many elevators may be located
Up to 4 elevator may be located in one hoistway
39
In very tall building express elevators are divided into zones with each serving a separate zone, a zone often includes how many consecutive floors
15-20 floors
40
Upper zone cars operate in express mode (with out stops) from what floor
From the first floor to the lowest floor of the upper zone
41
Blind hoistways are used for
Express elevator that serve the upper elevator zones in tall buildings
42
Single car blind hoistway access door are located every
3 Floors
43
Only trained personnel should attempt an evacuation of passengers from a stalled elevator car when using what
Elevator access panels
44
Top exit on electric traction elevators
are always provided and open outward and may be open from the inside
45
Top exit on Hydraulic elevators
may be provided depending on if the system has manual lowering valve or not
46
Side exits on elevators are required to have what to prevent car movement when the panels are open
Electrical interlocks
47
When a car is stopped in a blind hoistway what must be used to remove the passengers
The emergency Exits
48
What kind of duct is used over deep fat fryers and grills as part of the exhaust system for commercial cooking appliances
Grease Duct
49
Refuse and laundry chutes require
Sprinklers at the top of the chute and in the termination room
50
Pipe chase contains (5)
Hot and cold potable water Drain lines Steam Hot and chilled water for heating and air conditioning Sprinkler piping
51
In a Highrise office building the total HVAC system may be monitored and controlled by computers and include what (4)
Hundreds of feet of ductwork Heating equipment Refrigeration equipment Motors and blowers
52
Historically early forced air systems provided only heat through ducted system buildings included what two features to permit airflow through a building for ventilation and cooling and buildings were not airtight
Openable windows and Rooftop cupolas
53
Duct detectors are typically provided for fans with
Capacities exceeding 2000 cubic feet per minute
54
Air cooled chillers remove what
Heat from piped water systems in a building that passes through fan-coil or other ai handling equipment
55
Due to environmental concerns some halogenated refrigerants have been prohibited and replaced with what that also now pose a greater hazard for firefighters
Gasses like Butane and Propane
56
The space between a suspended ceiling and roof deck or under floor spaced may be utilized to provide supply air is called
Return Air Plenum
57
NFPA 90a in building 4 stories in height or leas
HVAC duct enclosures but be 1 hour fire rating
58
NFPA 90A in buildings 4 stories in hieght or more
HVAC duct enclosures must be 2 hour fire rating
59
Some Large hydronic systems have cooling towers stagged on a buildings what and in contrast HVAC equipment room may be located solely where in the building
Buildings Roof And Basement of the building
60
To Prevent the recirculation of smoke through HVAC system and to facilitate removal of the smoke some types of HVAC systems can be switched from normal operating mode to what
Smoke Control Mode
61
3 Following systems can signal HVAC controls to transfer to Smoke Control mode
Smoke Detectors Heat detectors Sprinkler waterflow switches
62
What are 3 Primary disadvantages of an automatic system is the number of elements that must be coordinated for maximum benefit
Fire Alarm Automatic Sprinkler HVAC zones
63
The advantages of Manual control
Elimination of system disruption due to false alarms and more specific system control
64
The Primary disadvantage of manual operation is
Its slower activation, compared to automatic operation
65
Rooftop smoke and heat vents are typically required on roofs of what kind of buildings
Large area buildings and in buildings with few windows including industrial storage and mercantile
66
Draft Curtain/Curtain boards depth will vary depending on the nature of the hazards with in an occupancy but should not be less then what
20% of the ceiling height
67
Draft Curtain/Curtain boards should be spaced
so that they are not father apart than eight times the ceiling height
68
One style of smoke control for stairways is the use of what
Smoke Towers
69
3 Expensive concessions for Smoke Towers
Location on the periphery of the floor plan Dedicated floor space in the building corridor access to the stairwell
70
A structural design that minimizes the use of space while still protecting stairways from the products of combustion is called
Pressurized stairwell
71
There are two types of pressurized stairs ways and they are called
Single-Injections system and Multiple-Injections system
72
A system that uses a fan to supply air to a stairwell at a single point is
Single injections system
73
A system that uses several discharge points along an air supply shaft running parallel to the stairwell from supply fan
Multiple injection systems
74
Stairwell pressurization systems require careful engineering analysis that
the pressure in the stairwell must be high enough that it will prevent the flow of smoke into a stairwell, but low enough to allow occupant access into the stairwell
75
In a compensated system the airflow into the stairwell can be adjusted depending on the number of what
Doors that may be open
76
Relief in a stair well is accomplished through the use of dampers that open to the outside relieving excess pressure in the stairwell
Overpressure relief
77
Transformers convert what
High voltage electricity from the eclectic utility service to an appropriate voltage for the building systems use
78
High Voltage equipment is defined as
Operating at 600 volts or higher
79
Low Voltage equipment is defined as
operates at less then 600 volts
80
what is the most common voltage delivered via transformers to medium and large buildings is
A 3 Phase 208/120V transformers
81
In Cases where power utility companies do not allow sprinkler protection for their equipment the utilities may permit what
Carbon dioxide detection systems
82
Transformers generate heat and the built in method of cooling the unit directly affects the hazard presented to emergency response personnel the two most common methods are
Use air and Oil
83
Air cooled transformers also called dry transformers use what
The Surrounding air to cool the unit through Fins, Heatsinks, and ventilation openings installed on the body of the transformer
84
Because the oil also provides electrical insulation it must have what
Dielectric properties
85
When Transformers are in side codes require
3 hour fire rating construction when no fire sprinkler and 1 hour fire rating construction when having fire sprinklers
86
Fuel storage for generators in hospitals and other critical facilities
May be up to 48 hrs or greater
87
Fuel storage should be located Separately from the generator an exception to the fuel storage separation is a day tank located in the same room or mounted directly on the generator, fire codes limit the tank to
60 gallons for diesel fuel