*Bk 29- Elevator Rescue Flashcards
What are the two types of cable elevators?
Drum and traction
Limitations in the length and diameter of the drum type elevator restricts the elevator to ________ ft lifts and slow speeds
150
Hydraulic elevators are generally limited to lifts up to how many stories?
6 stories
One of the locations an equipment room for a hydraulic elevator can be found is ____ to ____ feet away from the elevator shaft
50-100
The 4 types of elevator doors are?
- Swing hall
- Single slide
- Two speed
- Center opening
In elevators, what contacts the rollers on the hoistway door which releases the door latch on the hoistway door?
Pickup arm
What are gib blocks made out of?
Plastic or phenolic materials
What are the dimensions of a gib block? (Width, height, thickness)
3” wide by 1” high by 1/2” thick
How far apart are gib blocks placed?
Every 18” across the bottom
Normal hoistway doors can be expected to utilize how many gib blocks?
2
As a safety device, a centrifugal force governor will activate when an elevator travels in excess of ____ % of top speed
20%
During elevator rescues, what two areas need to have personnel equipped with portable radios?
- Elevator equipment room
2. Floor where elevator is inoperable
Do not rescue passengers using forcible entry methods unless?
Immediate medical attention is needed
When resetting an elevator, how long should you leave the power off before switching it on again?
30 seconds
Do not attempt to rescue trapped passengers from an inoperative
elevator until what has been done?
Power is switched off
On hydraulic elevators and some cable elevators, the hoistway doors will open once the elevator is within how many inches of floor level?
6”
On cable elevators, the hoistway doors will open once the elevator is within how many inches of floor level?
18”
When lowering a hydraulic elevator, open the bleeder valve slowly until?
You hear the sound of fluid moving
When trying to move an inoperable cable elevator, it is generally easier to move the car _______ (up or down)? because of counterweights.
Upward
Elevator side emergency exits are a minimum of what dimensions?
16” wide by 5 feet high