*Bk 100- Highrise Flashcards
What company is responsible to check two floors below the fire floor for the suitability for Staging?
The initial fire attack company
In high rise incidents the Rapid Intervention Company(s) is normally assembled and deployed from ________.
Staging
The Division Supervisor reports to the _______ or __________ and is responsible for fire suppression and rescue activities within a geographic area, usually aspecific floor.
Incident commander or operations chief
Who supervises and coordinates the activities of Lobby Control, Systems Control,Base, Ground Support, Supply Unit, Communications Unit, and Medical Unit?
Logistics chief
Requests from Staging for equipment and supplies will go through the _________ chief to Base or Ground Support.
Logistics
The Lobby Control Officer reports to the _________ chief or the ________.
Logistics section chief or IC (if logistics is not set up)
What group is responsible for locating and searching for unaccounted elevators which may contain building occupants?
Elevator group
If needed, a ___________ unit can be implemented to assist Lobby Control with monitoring and maintaining the buildings built-in fire control, life safety, environmental control, communications and elevator systems.
Systems control unit
If implemented, the systems control unit reports to who?
Logistics chief.
Can also be contacted directly from operations chief
The ___________ group is responsible for providing transportation for personnel,equipment, and supplies; providing refilling of SCBA cylinders and maintenance of SCBAs; provide fueling, service and maintenance of vehicles and portable power equipment and tools; and implementing the ground level traffic/movement plan at the incident including marking safe access routes and zones and coordinates the transportof equipment via the stairwells.
Ground support group
The Ground Support supervisor reports to the _______ Branch Director (if established) or the _________ Chief.
- Support branch director
2. Logistics chief
Base shall be established a minimum of _____ feet away from the incident structure.
200 ft
In a high rise incident, a minimum of a ____ member initial fire attack team shall ascend to the reported floor.
4
The second-in company to a high rise fire has what responsibly?
Establishing lobby control
The command post should be established a minimum of how many feet from the structure?
200 ft
Who has the ultimate responsibility to authorize (or discontinue) the use of elevators?
The incident commander
The Rapid Intervention Company at a high-rise should involve what kind of resource(s) as a minimum?
Light force, engine or squad AND an ALS rescue
Where should the RIC team be located during a high rise fire?
Staging or 1 floor below the fire
Once occupants have been evacuated from the structure, they should be moved a minimum of _____ feet from the affected structure.
200
Normally, how many companies should be kept at Base for each company held in staging?
2
How should you position an apparatus in the apparatus parking area of base?
Diagonally
Who is responsible for verifying a water supply is established in the standpipe system.
Lobby control
If the building is not equipped with pressurized stair shafts, utilize _______ to pressurize the stairwells.
Blowers
Do all access stairwells need to be pressurized?
Yes