Automated Chemistry Flashcards

1
Q

What is the measurement of the amount of light transmitted or absorbed by a colored solution

A

Spectrophotometery

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is the color that combined with another color and result in white light setting in which the spectrometry is set to measure the intended color wavelength

A

Complementary color

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is the distance between identical sites on consecutive waves

A

Wave lengths

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What wavelength for invisible light

A

190 to 390 nm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What wavelength for visible light

A

390-750 nm

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What color has the longest wavelength

A

Read

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What color has the shortest wavelength

A

Violet

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

What type of wavelength is the largest it is measured in centimeters

A

Radio waves

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

What is the measurement of the light allowed to pass through a solution

A

Percent transmittance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is the percent transmittance formula

A

I x 100/I

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What is the measurement of light absorbed by solution

A

Absorbance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

True or false percent transmittance is proportionally related to absorbance

A

False

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

_________ is based on the amount of measured molecules binding with a specific reagent

A

Concentration

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

The concentration of a solution at a constant light path length and at a constant wavelength and temperature is directly proportional to the amount of light absorbed
Applied: The concentration of a solution is directly proportional to its absorbance

A

Beer Lambert law

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

In spectrophotometric instruments what is used to absorb and filter certain wavelengths of light

A

Complementary monochromator

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

In spectrophotometric instruments what must be transparent to the wavelength used

A

Sample older

17
Q

What is this spectrophotometric formula

A

Cu= (Au/As) x Cs

18
Q

What sample type is used to eliminate color interference due colored reagents or specimens it is used to set the instruments absorbance reading 20

19
Q

What Blank type is used when the patient see him is lipemic or hemolyzed

A

Serum blank

20
Q

What blank type is used in some enzyme test

A

Water blank

21
Q

What blank type contains at least one of the reagents used in a procedure the most common like type

A

Reagent blank

22
Q

What sample type is a solution of exact known concentration

23
Q

What sample type is a solution of approximate concentration

24
Q

What order shut the different sample types be ran in

A

Blank standard control unknown

25
What methodology is based on different molecules having different philosophies in an electric field
Electrophoresis
26
What methodology utilizes antigen antibody reactions
Immuno assay
27
What methodology is used on mixtures of solutes dissolved in a common solvent are separated from one another by a differential distribution of solvents between two phases
Chromatography
28
What methodology is used for the separation of isoenzymes immunoglobulins in hemoglobin
Electrophoresis
29
What is a common quantitative immunoassay
ELISA
30
What methodology utilizes a technique that quantifies a particular company in pure form use for determining heavy metals drugs in other special chemistry procedures
Chromatography
31
What methodology measures electrical signals within an electro chemical cell
Electrical chemical technique
32
What electromechanical technique measures voltage differences between the two electrodes
Potentiometeric
33
What a electro mechanical technique measures the amount of current between two electrodes win a constant current is applied
Coulmetry
34
What electromechanical technique is commonly used to measure chloride ions in serum plasma urine and other body fluids
Coulmetry
35
What electromechanical technique is associated with I SE
Potentiometeric