ATA 49 - APU Flashcards
During refuel/defuel operations, when must not be used APU ?
- 1st attempt to start APU has failed
- Auto shutdown has occurred
- Fuel spillage
Which tank supplies APU ?
Left inner tank.
If no pressure, APU pump activates
Function of APU Master SW ?
- ECB self test
- Opens flap
- Opens fuel line
On which electrical bus APU starts ?
DC BAT bus
LOW OIL QTY on APU. Can you operate APU ?
Yes, 10h max
Low oil pressure on APU. Can you operate it ?
No
Parameters when APU is AVAIL ?
N > 99 %
or
N =95% + 2s
If APU bleed used, what time APU keeps running automatically after APU MASTER SW OFF?
1or 2 min for cooling purpose
How many start attemps for APU ? Cooling period ?
3 attempts. 60 min cooling
Can APU bleed be used for wings anti ice ?
No. Not powerful enough
List bleed priority, APU vs Engines ?
1/ APU
2/ENGINES
Can you start the APU using the aircraft BATTERIES ?
Yes
APU N limit on ECAM for amber ? Red ?
Amber = 102 %
Red = 107 %
What is the name of the computer that controls APU ?
Electronic Control Box (ECB)
If APU is started on batteries only, how much time maximum between batteries selected on AUTO and APU start ?
30 min
After 35 min batteries are 25% of their capacities