Description of cockpit oxygen system ?
1 bottle of oxygen
1 manual isolation valve
1 pressure regulator
2 overpressure lines and 1 green safety port
1 supply valve (solenoid)
1 distribution manifold
Which pressure on low pressure circuit activates REGUL LO PR message on ECAM DOOR page ?
50 psi
Oxygen pressure threshold to box oxygen pressure on ECAM Door page ?
1500 psi —> check Limitations on ground
Oxygen pressure threshold green flash on ECAM Door page ?
Only on some msn
800 psi (or 600 psi for one msn)
Oxygen pressure threshold amber on ECAM Door page ?
400 psi
N / 100 % button. N position = mixed air until which altitude ?
35 000 ft
Emergency selector. Continuous oxygen flow above which altitude ?
30 000 ft
(Provide 100% selected )
Oxygens masks in cabin fall. What does mean the green memo OXY PAX ON ? And amber ?
Green = 2 CPC detect excessive cabin altitude
Amber = 1 or 2 CPC do not detect excessive cabin altitude
Auto fall out of oxygen mask at which altitude ?
14 000ft
16 000ft if HI ALT LANDING pb
Autonomy of cabin oxygen altitude ?
15 min
13-15-22min depending on aircraft
Autonomy of smoke hoods ?
15 min