electrical/unknown fire VMC
*1. battery/gen switch- off
*2.100% oxygen- don
*3. airspeed- reduce
*4. cockpit enviro/aft air- off
fire persists
*5. engine fire- execute
fire extinguishes
*6. land as soon as possible
BREAK OUT POCKET CHECKLIST
electrical/unknown fire IMC
*1. utility bus switch- off
*2. all non-ess equipment- off
*3. 100% oxygen- don
*4. airspeed- reduce
*5. cockpit enviro/aft air- off
fire persists
*6. bailout- alt permitting
fire extinguishes
*7. land as soon as possible
smoke/fume elimination
*1. 100% oxygen- don
*2. airspeed- reduce
*3. cockpit enviro/aft air- fresh air increase
smoke/fumes/heat builds up
*4. canopy- emergency open
inflight damage/binding controls
- maintain control of AC, if not controllable- bail out
- climb- as required
- check flight characteristics >5000 AGL in landing configuration (no slower than 80 kias)
OCF
*1. controls- positively neutral
*2. PCL- idle
*3. altitude- check >5000 AGL
recovery not possible by 5000 ft
*4. bailout
if continuing recovery
*5. AOA/airspeed/turn needle- check for spin
if in a spin recover, if OCF hold neutral/idle until flying
*12. recover from unusual attitude
wind shear/ wake turbulence
*1. wave off
inverter failure
*1. other inverter- select
annunciator remains
*2. electrical control- take command
*3. circuit breakers- in (115vac/1amp, inv control, inv1, inv2)