Air: 22-24 (Optimisation) Flashcards
What is Feature 22?
Pest Control
What project types does Feature 22 apply to?
*Pest Control
- NEB
- NEI
What is the objective of Feature 22?
*Pest Control
Reduce unhygienic conditions and inspections for signs of infestation.
What are the 2 parts for Feature 22?
- Pest Reduction
- Pest Inspection
What are the strategies for Part 1 of Feature 22?
- *Pest Reduction*
- *Pest Control*
- Perishable food not in the refrigerator is stored in sealed containers
- Indoor Garbage Cans <113L have lids operated without the use of hands and enclosed by cabinetry with separate handle
- Indoor Garbage Cans >113L have lids
What is the strategy for Part 2 of Feature 22?
- *Pest Inspection*
- *Pest Control*
Visual inspections for signs of infestation of Cockroach and Termites.
What is Feature 23?
Advanced Air Purification
What project types does Feature 23 apply to?
*Advanced Air Purification
All
What are the parts for Feature 23?
- Carbon Filtration
- Air Sanitization
- Air Quality Maintenance
What is the strategy for Part 1 of Feature 23)?
- *Carbon Filtration*
- *Advanced Air Purification*
Buildings with recirculated air are installed with carbon filtration methods
What are the 2 methods for Carbon Filtration for Part 1 of Feature 23?
- *Carbon Filtration*
- *Advanced Air Purification*
- Install in ductwork as part of HVAC
- Install properly sized, standalone air purifiers
If installed as ductwork as part of an HVAC system, what are the 2 types of filters to be used for Part 1 of Feature 23?
- *Carbon Filtration*
- *Advanced Air Purification*
- Activated carbon filters
- Combination particulate/carbon filters
If installing properly sized, standalone air purifiers for Part 1 of Feature 23, where are these air purifiers to be located at?
- *Carbon Filtration*
- *Advanced Air Purification*
Regularly occupied spaces
What are the requirements for the application of strategies from Part 2 of Feature 23?
- *Air Sanitization*
- *Advanced Air Purification*
- Buildings with recirculated air
- Spaces with >10 regular occupants
What is the strategy for Part 2 of Feature 23?
- *Air Sanitization*
- *Advanced Air Purification*
Having a standalone or HVAC-integrated UVGI system or Photocatalytic Oxidation System
What are the 2 strategies for Part 3 of Feature 23?
- *Air Quality Maintenance*
- *Advanced Air Purification*
- System maintenance per manufacturer’s recommendations
- Annual submission of maintenance records to IWBI
What is Feature 24?
Combustion Minimization
What project types is Feature 24 applicable to?
*Combustion Minimization
All
The incomplete combustion of fuels leads to the production of?
Carbon Monoxide (CO)
What are the symptoms of exposure to Carbon Monoxide?
- Headaches
- Nausea
- Loss of consciousness
What are the 4 parts of Feature 24?
*Combustion Minimization
- Appliance and Heater Combustion Ban
- Low-Emission Combustion Sources
- Engine Exhaust Reduction
- Construction Equipment
What is the strategy for Part 1 of Feature 24?
- *Appliance and Heater Combustion Ban*
- *Combustion Minimization*
No combustion-based equipment in regularly occupied spaces
What are some examples of combustion-based equipment?
- Fireplaces
- Stoves
- Ovens
What is the strategy for Part 2 of Feature 24?
- *Low-Emission Combustion Sources*
- *Combustion Minimization*
Combustion-based equipment used for heating, cooling, water heating, process heating or power generation meet SCAQMD standards for pollution
Give 3 examples of combustion-based equipment used for heating, cooling, water heating, process heating or power generation

- Boilers
- Steam Generators
- Water Heaters
What is the strategy for Part 3 of Feature 24?
- *Engine Exhaust Reduction*
- *Combustion Minimization*
Signage prohibiting the idling of vehicles for >30 seconds
What are the 3 locations for signages stating the prohibition of idling vehicles for Part 3 of Feature 24?
- *Engine Exhaust Reduction*
- *Combustion Minimization*
- Pick-up
- Drop-off
- Parking areas
What is the objective of Part 4 of Feature 24?
- *Construction Equipment*
- *Combustion Minimization*
Reduce the amount of PM produced on a construction site 1 year prior to performance verification
What are the 3 strategies for Part 4 of Feature 24?
- *Construction Equipment*
- *Combustion Minimization*
- Non-road and Off-road diesel vehicles or equipment complying with standards and being retrofitted with emission-reducing technology upon delivery to the project site
- On-road and Off-road vehicles and equipment being operated, loaded and unloaded away from air intakes or openings of adjacent buildings
In Part 4 of Feature 24, what is the standard of compliance for non-road diesel vehicles or equipment?
- *Construction Equipment*
- *Combustion Minimization*
EPA Tier 4 PM standards or local equivalent
In Part 4 of Feature 24, what is the standard of compliance for on-road diesel vehicles or equipment?
- *Construction Equipment*
- *Combustion Minimization*
EPA 2007 PM standards or local equivalent
In Part 4 of Feature 24, what are the approving organisations for emission-reducing technology for on-road and off-road diesel vehicles or equipment?
- *Construction Equipment*
- *Combustion Minimization*
- EPA
- CARB
What are Features 22, 23 and 24?
- 22 = Pest Control
- 23 = Advanced Air Purification
- 24 = Combustion Minimization