Air: 22-24 (Optimisation) Flashcards
What is Feature 22?
Pest Control
What project types does Feature 22 apply to?
*Pest Control
- NEB
- NEI
What is the objective of Feature 22?
*Pest Control
Reduce unhygienic conditions and inspections for signs of infestation.
What are the 2 parts for Feature 22?
- Pest Reduction
- Pest Inspection
What are the strategies for Part 1 of Feature 22?
- *Pest Reduction*
- *Pest Control*
- Perishable food not in the refrigerator is stored in sealed containers
- Indoor Garbage Cans <113L have lids operated without the use of hands and enclosed by cabinetry with separate handle
- Indoor Garbage Cans >113L have lids
What is the strategy for Part 2 of Feature 22?
- *Pest Inspection*
- *Pest Control*
Visual inspections for signs of infestation of Cockroach and Termites.
What is Feature 23?
Advanced Air Purification
What project types does Feature 23 apply to?
*Advanced Air Purification
All
What are the parts for Feature 23?
- Carbon Filtration
- Air Sanitization
- Air Quality Maintenance
What is the strategy for Part 1 of Feature 23)?
- *Carbon Filtration*
- *Advanced Air Purification*
Buildings with recirculated air are installed with carbon filtration methods
What are the 2 methods for Carbon Filtration for Part 1 of Feature 23?
- *Carbon Filtration*
- *Advanced Air Purification*
- Install in ductwork as part of HVAC
- Install properly sized, standalone air purifiers
If installed as ductwork as part of an HVAC system, what are the 2 types of filters to be used for Part 1 of Feature 23?
- *Carbon Filtration*
- *Advanced Air Purification*
- Activated carbon filters
- Combination particulate/carbon filters
If installing properly sized, standalone air purifiers for Part 1 of Feature 23, where are these air purifiers to be located at?
- *Carbon Filtration*
- *Advanced Air Purification*
Regularly occupied spaces
What are the requirements for the application of strategies from Part 2 of Feature 23?
- *Air Sanitization*
- *Advanced Air Purification*
- Buildings with recirculated air
- Spaces with >10 regular occupants
What is the strategy for Part 2 of Feature 23?
- *Air Sanitization*
- *Advanced Air Purification*
Having a standalone or HVAC-integrated UVGI system or Photocatalytic Oxidation System