Air: 16-18 (Optimisation) Flashcards
What is Feature 16?
Humidity Control
What project types (NEB; NEI; C&S) does Feature 16 (Humidity Control) apply to?
- NEB
- NEI
Low Humidity vs High Humidity
What is the reason for Feature 16 (Humidity Control)?
-
Low humidity
- causes dryness and irritation of eyes, throat and mucous membranes
-
High humidity
- promotes the accumulation and growth of pathogens such as bacteria and mold
- Increased off-gassing of building materials
Formaldehyde
Give an example of a building material off-gassing at a higher rate due to high humidity.
Offgassing of formaldehyde increases 1.8-2.6x when humidity increases by 35%
Add or Remove; Modeled
What are the strategies for Feature 16 (Moisture Control)?
Either
- Ability to add or remove moisture of HVAC to maintain humidity within 30-50%
- Modeled humidity levels maintained at 30-50% for 95% of hours in the previous year
What is Feature 17?
Direct Source Ventilation
What project types (NEB; NEI; C&S) does Feature 17 (Direct Source Ventilation) apply to?
All
- NEB
- NEI
- C&S
Separate; Vent
What is the objective of Feature 17 (Direct Source Ventilation)?
- Separate harmful sources of air pollution from occupied spaces
- Actively vent pollutants to the outside
Closed; Expelled
For Feature 17 (Direct Source Ventilation), in the scenario that a space is not in accordance with the following standards
- Low-emission standards of Ecologo CCD 035
- Blue Angel RAL-UZ 171
- Green Star
what are the strategies recommended?
- Closed from adjacent spaces with self-closing doors
- Air inside expelled from the spaces
What is Feature 18?
Air Quality Monitoring and Feedback
What project types (NEB; NEI; C&S) is Feature 18 (Air Quality Monitoring and Feedback) applicable to?
- NEB
- NEI
Monitoring; Record; Display
What are the parts for Feature 18 (Air Quality Monitoring and Feedback)?
- Indoor Air Monitoring
- Air Data Record Keeping and Response
- Environmental Measures Display
Particle; CO2; O3
What is the strategy for Part 1 (Indoor Air Monitoring) for Feature 18 (Air Quality Monitoring and Feedback)?
Monitors taking 2 measurements of indoor pollutants 1.2m–1.8m above the floor in regularly occupied / common areas, (1 measurement / floor) / hour.
Written Policy; 3 Years; Unacceptable
What are the strategies for Part 2 (Air Data Record Keeping and Response) of Feature 18 (Air Quality Monitoring and Feedback)?
- Written policy providing details of monitoring and record keeping of pollutants listed in Part 1 (Indoor Air Monitoring) of Feature 18 (Air Quality Monitoring and Feedback)
- Records kept for a minimum of 3 years
- Plan in place to address unacceptable conditions
Display; Size; Parameters
What are the strategies for Part 3 (Environmental Measures Display) of Feature 18 (Air Quality Monitoring and Feedback)?
A real-time display based on the following condition and displaying such:
- 15cm x 13cm / 10,000 ft2
- Temperature, Humidity, CO2