Air: 16-18 (Optimisation) Flashcards

1
Q

What is Feature 16?

A

Humidity Control

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What project types (NEB; NEI; C&S) does Feature 16 (Humidity Control) apply to?

A
  • NEB
  • NEI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Low Humidity vs High Humidity

What is the reason for Feature 16 (Humidity Control)?

A
  • Low humidity
    • causes dryness and irritation of eyes, throat and mucous membranes
  • High humidity
    • promotes the accumulation and growth of pathogens such as bacteria and mold
    • Increased off-gassing of building materials
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

Formaldehyde

Give an example of a building material off-gassing at a higher rate due to high humidity.

A

Offgassing of formaldehyde increases 1.8-2.6x when humidity increases by 35%

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Add or Remove; Modeled

What are the strategies for Feature 16 (Moisture Control)?

A

Either

  • Ability to add or remove moisture of HVAC to maintain humidity within 30-50%
  • Modeled humidity levels maintained at 30-50% for 95% of hours in the previous year
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What is Feature 17?

A

Direct Source Ventilation

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

What project types (NEB; NEI; C&S) does Feature 17 (Direct Source Ventilation) apply to?

A

All

  • NEB
  • NEI
  • C&S
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

Separate; Vent

What is the objective of Feature 17 (Direct Source Ventilation)?

A
  • Separate harmful sources of air pollution from occupied spaces
  • Actively vent pollutants to the outside
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Closed; Expelled

For Feature 17 (Direct Source Ventilation), in the scenario that a space is not in accordance with the following standards

  • Low-emission standards of Ecologo CCD 035
  • Blue Angel RAL-UZ 171
  • Green Star

what are the strategies recommended?

A
  • Closed from adjacent spaces with self-closing doors
  • Air inside expelled from the spaces
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

What is Feature 18?

A

Air Quality Monitoring and Feedback

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What project types (NEB; NEI; C&S) is Feature 18 (Air Quality Monitoring and Feedback) applicable to?

A
  • NEB
  • NEI
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Monitoring; Record; Display

What are the parts for Feature 18 (Air Quality Monitoring and Feedback)?

A
  • Indoor Air Monitoring
  • Air Data Record Keeping and Response
  • Environmental Measures Display
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Particle; CO2; O3

What is the strategy for Part 1 (Indoor Air Monitoring) for Feature 18 (Air Quality Monitoring and Feedback)?

A

Monitors taking 2 measurements of indoor pollutants 1.2m–1.8m above the floor in regularly occupied / common areas, (1 measurement / floor) / hour.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Written Policy; 3 Years; Unacceptable

What are the strategies for Part 2 (Air Data Record Keeping and Response) of Feature 18 (Air Quality Monitoring and Feedback)?

A
  • Written policy providing details of monitoring and record keeping of pollutants listed in Part 1 (Indoor Air Monitoring) of Feature 18 (Air Quality Monitoring and Feedback)
  • Records kept for a minimum of 3 years
  • Plan in place to address unacceptable conditions
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Display; Size; Parameters

What are the strategies for Part 3 (Environmental Measures Display) of Feature 18 (Air Quality Monitoring and Feedback)?

A

A real-time display based on the following condition and displaying such:

  • 15cm x 13cm / 10,000 ft2
  • Temperature, Humidity, CO2
How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

What are Features 16, 17 and 18?

A
  • Feature 16 = Humidity Control
  • Feature 17 = Direct Source Ventilation
  • Feature 18 = Air Quality Monitoring and Feedback