acts and regs Flashcards
Gas appliance servicing technicians are limited to light commercial appliances up to an input of:
280,000 BTUH
Regulated work means:
all of the above are correct
Incidents must be reported to the appropriate safety manager:
as soon as practicable after the incident
How soon can a person rewrite an examination if he/she fails to pass the initial attempt?
30 days
How many non-qualified workers can a person holding a valid certificate of qualification supervise?
no more than the ratio established by the regulations
A contractor’s license may be issued for a period of up to:
5 years
The homeowner’s application for a permit to perform regulated work must include:
the name of each person other than immediate family members who will be assisting with the regulated work
An installation permit may not be issued to:
a renter who applies on behalf of the homeowner who performs regulated work as permitted under the regulations
The term ‘gas equipment’ includes:
all of the above
When the term ‘gas system’ is used, it is making specific reference to:
gas equipment that is installed downstream of the service meter
‘The plant or premises where gas received from a pipeline is metered, reduced in pressure and prepared for distribution to individual users of the gas’ is a good definition of the term:
city gate
A distribution main is limited to a pressure of:
100 psig (700 kPa)
A fully detached dwelling is:
a detached building containing one dwelling and occupied by the owner
According to the gas safety regulations, the term ‘gas’ does not include:
Fuel oil
‘A Category 1 appliance as defined in CSA B149.1 that has a draft hood or draft diverter and is not equipped with a mechanical device for supplying combustion air’ is a good definition of the term:
natural draft appliance
A service meter can only be installed by:
an authorized employee of the gas company
Polyethylene piping may be installed in a gas system by:
a class ‘A’ or class ‘B’ gas fitter who has successfully completed training recognized by the provincial safety manager
An applicant for a class ‘A’ gas fitter’s certificate of qualification must have held a class ‘B’ gas fitter’s certificate of qualification for a minimum of:
2 years
A class ‘B’ gas fitter certificate of qualification entitles the holder to perform the installation or alteration under an appropriate permit of:
any of the above
A class ‘B’ gas fitter can perform electrical work that is restricted to the installation, repair, and maintenance of appliances firing on:
gaseous, liquid, or solid fuels
A class ‘B’ gas fitter is not allowed to install a thermostat if the voltage exceeds:
24 VAC
What is a class ‘B’ gas fitter allowed to install?
Class 2 circuit wiring up to a rated output of 100 volt amps.
What may a class ‘B’ gas fitter do if gas is leaking from a gas supply system?
Make necessary temporary repairs before advising the gas company.
What does a gas appliance service certificate of qualification entitle the holder to service?
A commercial furnace if its rated capacity does not exceed 82 kW.