201.21 Containment Isolation Flashcards
- 201.21 Containment Isolation*
- *
What are the Fission Product Boundaries
Fuel Cladding
RCS
Containment Building
- 201.21 Containment Isolation*
- *
Function of an ESF System
Control and Limit the release of fission products to prevent exceeding 10CFR50.67 limits following a LOCA or fuel handling accident
- 201.21 Containment Isolation*
- *
Function of Containment Isolation System
Preserves integrity of the containment boundary, preventing/limiting releases of fission products to the environment during a LOCA or fuel handling accident.
Isolates non-essential fluid lines while allowing passage of others to important systems under emergency conditions.
- 201.21 Containment Isolation*
- *
3 types of lines that require isolation
Form part of RCS Pressure Boundary
Connect directly to containment atmosphere
Part of a closed system
- 201.21 Containment Isolation*
- *
Types of Containment Penetrations
Piping
Electrical
Fuel Transfer Tube
Personel / Aux Airlock
Instrumentation
- 201.21 Containment Isolation*
- *
Piping Penetrations
Single line per penetration for high energy lines
( > 200 F or 225 psig)
Multiple pipes for low energy
Sleeve welded to RCB wall, plate welded to sleeve and pipe
- 201.21 Containment Isolation*
- *
Electrical Penetrations
Multiple Canister Type
Canister welded to RCB wall, electrical assembly flanged to canister
- 201.21 Containment Isolation*
- *
Fuel Transfer Tube
Blind flange IRC
Manual locked closed valve ORC
- 201.21 Containment Isolation*
- *
Airlocks
Inner and Outer Doors
- 201.21 Containment Isolation*
- *
Instrumentation
Bellows IRC, fluid filled tube through wall, diaphragm / transmitter ORC
- 201.21 Containment Isolation*
- *
Types of Containment Isolation
Phase A
Phase B
Main Steamline Isolation
Feedwater Isolation
Containment Ventilation Isolation
- 201.21 Containment Isolation*
- *
Phase A Isolation
Actuated by:
SI
Manually from MCR
Isolates valves in systems not needed to support safety systems
- 201.21 Containment Isolation*
- *
Systems affected by Phase A
All Sample lines (CP-002)
CVCS Letdown and Charging
CVCS Seal Water Supply and Return
RCDT Vent and Discharge
RCB Normal Sump Discharge
Air supply to PAL solenoids
PRT Vent and Spray
SIS Accumulator Test and N2 Supply
RCB Chill Water
IA to RCB
FP to RCB
Normal and Supplemental Purge
◦Also Containment Radiation Monitors (RT-8011, 8012 & 8013
- 201.21 Containment Isolation*
- *
Phase B Isolation
Actuated by:
Hi-3 Conatinment Pressure 9.5 psig
Manually from MCR
(2/2 on 1 of 2 sets of switches, CP-005, CP-002)
- 201.21 Containment Isolation*
- *
Main Steam Line Isolation
Actuated by:
Low Steam Pressure < 735 psig (2/3 any S/G)
Hi-2 Containment pressure 3.0 psig
Hi Steam Pressure Rate 100 psig (instant) or 100 psig/50 sec below P-11 (< 1985# RCS) with Lo Steam Line Pressure SI blocked
- 201.21 Containment Isolation*
- *
Feedwater Isolation
Actuated by:
SI
S/G Level Hi-Hi (P-14) >87.5%, 2/4 on 1 S/G
Rx Trip (P4) and lo Tave (574 F)
- 201.21 Containment Isolation*
- *
Containment Ventilation Isolation
Actuated by:
Hi Rad in RCB Purge Exhaust (Norm or Supp)
SI
Manual - 1/2 Phase A/CVI switches in MCR
2/2 on 1/2 Containment Spray Actuation Switches
- 201.21 Containment Isolation*
- *
Systems affected by a Phase B
6 CCW valves to/from RCPs (2 inlet, 4 outlet)
- 201.21 Containment Isolation*
- *
Systems affected by a Maint Steam Line Isolation
All MSIVs and MSIV Bypass Valves
- 201.21 Containment Isolation*
- *
Valves affected by Feedwater Isolation
Feedwater Reg Valves
Feedwater Bypass Reg Valves
Feedwater Isolation
Feedwater Isolation Bypass
Feedwater Pre-heater Bypass Valves
- 201.21 Containment Isolation*
- *
Systems affected by Containment Ventilation Isolation
Normal and Supplemental Purge
8011
Tech Specs
- 6.1.1 Containment Integrity
- 6.1.2 Containment Leakage
Without Integrity or leakage exceeding limits, restore in 1 hour, or be in Mode 3 in 6 hours, and Mode 5 30 hours later.
- 201.21 Containment Isolation*
- *
Instrumentation and Controls Available to Monitor and Operate Containment Isolation
ESF Status Monitoring Bypass/Inop and F/Act lights
Phase A and B - CP-002
MS and FW - CP-006
CVI - CP-022