11.08 Fire Protection Flashcards
What are the systems that make up the fire protection system?
- Detection
- Extinguishing
There are two continuous loop detection system types, what are they?
- Pneumatic pressure
- Semi conductor
What happens to the semiconductor material as heat rises?
- Resistance decreases
The smoke detector that uses a radiation source is what type?
Ionisation type
How is a fire warning indicated?
- Aural red attention getters
- Message on CAS
When is fire detection indicated on a dual loop system?
When both sensors detect at the same time
The detection system system does not operate when?
Dual sensor or channel failure
What additional features does the APU detection have?
Flashing red light and horn in the wheel well
Which areas are covered by the detection system?
- Engines
- APU
- Wheel wells
- Cargo areas
What type of sensor is a spot sensor?
Bi-metallic switch
Discharge heads are related to cargo compartments in what way?
Heads = bays
A class D compartment consists of?
Area under detection without ventilation
what must be checked on portable extinguishers?
- Visual
- Date
- Check of usage
What is the maximum bend allowance of a semiconductor loop system?
3.2mm
What portable extinguisher will be used on class B & E cargo compartment?
Halon or water with nozzle