1. Fire Scene (pt 6) Flashcards
1
Q
How to properly conduct a reverse out.
A
- When leaving supply at apparatus tell FF to get hydrant adapter
- Connect 5 inch to large diameter discharge
- Open tank to pump and large diameter discharge [give water at idle; don’t worry about pressures at first]
- Then get supply [I can keep pump at idle, unless flows require more]
2
Q
What do I do if I have a Pump failure. (5)
A
- Emergency traffic
- Take out of pump [if another apparatus is pumping through me.]
- If I have a hydrant I still have some intake pressure. [I might be able to pump a 2 1/2]
- If any available apparatus, I can connect in to them and at least have them boost my pressure and give me their tanks
- Another apparatus needs to get a [second?] supply and boost my intake pressure with 5inch or 2 1/2 supply
- I might be able to connect 5” from my intake to another engine for them to either pump me or pull lines off their truck