The typical width of the spread-out proton Bragg’s peak (SOBP) is _____________.
a. 2 to 16 mm
b. 2 to 16 cm
c. 1 to 25 mm
d. 1 to 25 cm
b. 2 to 16 cm
Cone beam CT _______________________.
a. uses a fan beam
b. has a 3D extended digital array
c. has an area detector with 2D extended digital array
d. has multiple rotational speeds
c. has an area detector with 2D extended digital array
Which of the following is the only approach to managing motion that allows for real-time feedback?
a. 4DCT
b. Gated treatment
c. RPM system
d. Electromagnetic transponder
d. Electromagnetic transponder
For the ultrasound unit to know where it is in reference to the linear accelerator, it must be ________________ with the treatment delivery unit.
a. Localized
b. Attenuated
c. B-moded
d. Registered
d. Registered
Electronic portal imaging devices (EPID) can \_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_\_. I. use MV and kV II. take orthogonal images III. send images to multiple locations a. I and II b. II and III c. I and III d. I, II, and III
b. II and III
EPID uses only MV to create beam’s-eye view images.
Which of the following is the motion management method that defines an internal target volume?
a. OBI
b. compression
c. conservative
d. MIP
c. conservative
The internal target volume approach is simple and encompasses the maximum extent of the target through the breathing cycle, thus making it conservative.
Heavy charged particles like protons have a(n) __________ fall-off in tissue that is desirable.
a. continuous
b. Sharp
c. shortened
d. Absent
b. Sharp
An advantage of proton treatment is the Bragg Peak and the sharp fall-off.
Which of the following is a goal of radiation oncology?
a. Reduce side effects
b. Deliver accurate and precise treatments
c. Increase toxic effects
d. All of the above
a. Reduce side effects
As half-life increases, the overall activity ______________________.
a. Increases
b. Decreases
c. remains unchanged
b. Decreases
The relationship between half-life and activity is inversely proportional. As half-life increases, overall activity decreases.
Of the following, which radionuclide is used for permanent prostate implants?
a. Gold 198
b. Cobalt 60
c. Cesium 137
d. Iridium 192
a. Gold 198
A beta minus particle is also known as a(n) ____________.
a. electron
b. proton
c. hadron
d. neutron
a. electron
The coulomb is the metric unit of electrical ______________.
a. mass
b. charge
c. energy
d. frequency
b. charge
Rest mass refers to the _______ of a particle when it is not moving.
a. energy
b. charge
c. Force
d. weight
d. weight
A radioactive sample is measured to contain 1,000 mCi of radioactivity. If the decay constant of this isotope is 0.105 hr-1, how much activity will remain after 48 hours?
a. 6.474 mCi
b. 7.368 mCi
c. 0.154 mCi
d. 15.445 mCi
a. 6.474 mCi
At = Aoe–t = (1000 mCi)e(–0.105)(48) = 6.474 mCi.
Wavelength is represented by ______________.
a. lambda
b. Hertz
c. Inch
d. second
a. lambda