VENTILATION Panel Flashcards
BLOWER pb - Fault light (Amber)
Air pressure low*
Computer Fault*
Smoke
Overheat*
*horn sounds if on ground and no engines running
BLOWER pb - OVRD (White)
Goes to closed configuration (inlet & extract values close)
Air conditioning air added
Blower fan stops
BLOWER & EXTRACT pb - Both AUTO
On ground
- prior to takeoff, OPEN config
- after takeoff power, CLOSED config
*May be in Closed config prior to takeoff power if skin temp is too cold
EXTRACT pb - Fault light (Amber)
Air pressure low*
Computer fault
Smoke
*Horn sounds if on the ground and no engines running
EXTRACT pb - OVRD (White)
Goes to Closed config (inlet & extract value closes)
Air conditioning air added
CAB FANS pb - Off
Turns off cabin fans
NOTE: if both blower and extract pb to OVRD
Intermediate Config
Air conditioning air added
Blower Fan Stops