United States Pharmacopeia 800: Hazardous Pharmaceuticals Part 2 Flashcards
HD sterile compounding must take place in an ISO class ____ or better environment
5
Acceptable C-PECs for compounding of HDs are Class II biologic safety ____ (BSC) or Compounding aseptic containment isolators (CACI)
cabinets
The C-PECs must be placed in a ____ room (C-SEC).
containment secondary engineering control
C-SEC air exchanges need at least ____ air changes per hour and externally vented
12
C-SEC must have fixed walls in the ISO class ____ room
7
You must monitor ____, ____, and ____ with C-SECs
air exchanges, temperature, and humidity
A sink must be placed at least ____ meter from the entrance to the negative pressure buffer room
one
A Closed-system drug transfer device (CSTD) protects the compounder from exposure to ____ when the medication is withdrawn from a vial.
aerosols