Underground Operations Flashcards
What is meant by the term “intrinsically safe”
The electrical design of the circuits are such that they will not produce an electrical sparks capable of producing an explosion
What is meant by the term “intrinsically safe apparatus”
An apparatus in which all the circuits are intrinsically safe
What is the LEL
Lower Explosive Limit - a concentration expressed as a percentage below which a flammable gas will not explode in air, but at or above which it will explode when simply exposed to air
What is a SCBA
Self Contained Breathing Apparatus
What is a SABA
Surface to Air Breathing Apparatus - a mask with a hose that goes to the surface - good for approx 300 ft
What is the OSHA definition of a confined space?
any vessel, container, or room with a limited means of entry and egress, little to no ventilation, not intended for continual occupancy and where a potential for engulfment may occur
What 7 things does our Gas monitors monitor and at what point will the alarm go off
O2 levels <19.5 and >23.5 LEL 10% Hydrogen Sulfide( H2S) - 10 ppm Carbon Monoxide (CO) - 35 ppm Carbon Dioxide (CO2) - 5,000 ppm Airflow - if tube becomes bent or clogged (restricted) Barometer
At what interval should you report monitor readings
every 1-5 minutes
What O2 reading indicates LEL may not be accurate
< 12%
What factor can alter or give neg readings
Humidity
What type of gas meter is used by the team
GasAlertMicro 5 IR