TRAINING BULLETIN 160-195 EXAM Flashcards
TB 165
WHAT IS TB 165
ILLEGAL MARIJUANA OPERATORS OFTEN USE LARGE QUALITIES OF ELECTRICITY UP TO _____ TIMES MORE?
ILLEGAL MARIJUANA
10X TIMES MORE
TB 165
IN 1996, CALIFORNIA PROP ___ LEGALIZED MEDICAL MARIJUANA
PROP 21
TB 165
AFTER KNOCK-DOWN AND LIFE HAZARD HAS BEEN ADDRESSED AT A MARIJUANA FIRE, TRANSITION TO ?
HAZ MAT & CRIME SCENE
TB 165
THE FEDERAL DEPARTMENT OF JUSTICE CLASSIFIED MARIJUANA AS A LEVEL __ SUBSTANCE
LEVEL 1 (PTQ)
TB 165
IN ______, CALIFORNIA PROP 21 LEGALIZED MARIJUANA FOR MEDICAL USE
1996
TB 165
IN _____, CALIFORNIA LEGALIZED MARIJUANA USE FOR 21 YEAR OLDER
JAN 2017
TB 165
AN ____ OXYGEN ATMOSPHERE IS DEFICIENT. OZONE & CARBON DIOXIDE ARE BOTH USED TO ENHANCE MARIJUANA GROWING?
19.5 (PTQ)
TB 165
CALIFORNIA LEGISLATION ALLOWS NON-PROFIT COLLECTIVES, REFERRED TO AS COOPERATIVE OR DISPENSARIES TO PROVIDE TO PATIENT AT ?
AT COST
TB 165
COMMUNICATE _____ VIA RADIO AS SOON AS IT BECOMES KNOWN THAT AN ILLEGAL MARIJUANA OPERATIVE IS INVOLVED WITH FIRE
ILLEGAL MARIJUANA OPERATION
TB 165
DURING A ILLEGAL MARIJUANA OPERATION RESPONSE, MEMBER WITHIN ___ FT SHALL BE IN FULL PPE’S
30 FEET
TB 165
ILLEGAL MARIJUANA OPERATIONS OFTEN USE IMPROVED EXPLOSIVE DEVICES & BOOBY TRAPS. WHAT IS AN
APD?
ANTI PERSONNEL DEVICE
TB 165
WHEN RESPONDING TO AN ILLEGAL MARIJUANA OPERATION AND EXPLOSION ARE HEARD, CONSIDER ?
RAPID EXTRICATION
TB 165
ILLEGAL MARIJUANA OPERATORS HAVE TWO GOALS?
OPTIMAL GROWING CONDITIONS
A CLANDESTINE OPERATIONS
( NOT TO BE COME LEGAL)
TB 165
AN 19.5 OXYGEN ATMOSPHERE IS DEFICIENT. ___ & ____ ARE BOTH USED TO ENHANCE MARIJUANA
OZONE & CARBON DIOXIDE
TB 170
WHAT IS TB170
NARCAN IS EMERGENCY MEDICATION FOR ?
NARCAN
SUSPECTED OVERDOSE
TB 170
THE NEW NARCAN MEDICATION IS ADMINISTERED BY ?
SPRAY
TB 170
THE NEW NARCAN IS PRE-METERED AT __ MGS
4MG
TB 170
THE NEW NARCAN MEDICATION SHOULD BE USED WHEN A PATIENT IS IN RESPIRATORY ARREST OR HYPOVENTILATION AT ____ BREATHS OR LESS PER MIN
8
TB 170
NARCAN MEDICATION CAN BE ADMINISTERED BY LAFD PARAMEDIC TO A PEDIATRIC PATIENT ___ YEARS OR MORE
1 YEAR
TB 170
AFTER ADMINISTERING NARCAN, PAY PARTICULAR ATTENTION FOR INCREASE RISK OF ?
VOMITING
TB 172
WHAT IS TB 172
LITHIUM (LI-ION) AUTO ATTERY SYSTEMS CAN RANGE FROM __ TO ___ PLUS VOLTS
ELECTRICAL VEHICLES
100 TO 500
TB 172
LITHIUM-ION AUTO BATTERY SYSTEMS CONTINUE TO GENERATE __ WELL AFTER THE FIRE IS EXTINGUISHED
HEAT
TB 172
LITHIUM-ION AUTO BATTERY SYSTEMS, UP TO _____ UNITS ( TELSA MODEL X), COMPRISE THE BATTERY PACK
8,200 UNITS
TB 172
LITHIUM-ION AUTO BATTERIES ARE SUBJECT TO _____ WHEN IT HAS BEEN DAMAGE FROM PENETRATION, CRUSHING, EXPOSED TO HEAT, OR INTERNAL SHORT CIRCUIT TO A FACTORY DEFECT OR AGING
THERMAL RUN-A-WAY
TB 172
THE NFPA SHOW THAT ABOUT 90 CARS CATCH FIRE FOR EVERY ____ MILES DRIVEN IN THE US
1 BILLION
TB 172
LITHIUM-ION AUTO BATTERY SYSTEM FIRE TEMPERATURES CAN EXCEED OVER ____ DEGREES FAHRENHEIT AND THEY WILL SUFFER A SELF-DESTRUCTION OF ITS STRUCTURE
900 DEGREES
TB 172
ELECTRONIC VEHICLES ARE _____ TO IGNITE IN A COLLISION THAN INTERNAL COMBUSTION ENGINE VEHICLE
LESS LIKLEY
TB 172
ELECTRONIC VEHICLE FIRES ARE PRIMARILY DUE TO ?
HIGH SPPED IMPACTS
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE INCIDENT, ___ CAN IDENTIFY ANY DIRECT CURRENT
NO KNOWN TOOL
TB 172
AN EXPOSED ELECTRONIC VEHICLE BATTERY, WIRING AND/OR COMPONENTS CAN ___ YOU IF YOU MAKE CONTACT WITH IT
KILL
TB 172
ESTABLISH A __ FOOT SAFETY ZONE WHEN EXTINGUISHING AN EV FIRE WITH WATER AND WEAR FULL STRUCTURE FIRE PPE AND SCBA
30 FEET
TB 172
DURING NFPA TESTING, IT WAS DETERMINED THAT IT COULD TAKE ____ & UP TO ___ GALLONS OF WATER TO EFFECTIVELY COOL DOWN THE BATTERY
2,600 TO 3,000
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE FIRE INCIDENT, BATTERY COOLING CAN ONLY TAKE PLACE IF WATER IS __ THE BATTERY
INTRODUCED INSIDE BATTERY
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE INCIDENT, TO ELIMINATE ELECTROCUTION HAZARD WEAR THE DEPARTMENT APPROVED GAUNTLET GLOVES WHEN IN CONTACT WITH THE ___, INCLUDING INCIDENT THAT REQUIRED EXTRICATION
VEHICLE
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE INCIDENT WITH POSSIBLE DAMAGE TO THE BATTERY SYSTEM, MAKE EVERY ATTEMPT TO DISCONNECT THE DC ELECTRICAL BATTERY AT THE VEHICLE’S ________ LOOP.
FIRST RESPONDER LOOP
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE INCIDENT WITH POSSIBLE DAMAGE TO THE BATTERY SYSTEM, CONSULT VEHICLE MANUFACTURER FOR THE LOCATION OF THE FIRST RESPONDER LOOP AND ___ THE WIRING TO ENSURE THEY WILL NOT TOUCH
DOUBLE CUT
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE FIRE INCIDENT, IS FOAM EFFECTIVE ?
NO
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE FIRE INCIDENT, USE ____ WATER PRESSURE IN A LOW-FLOW FOG ( NO STRAIGHT STREAM). THE GOAL IS TO KNOCK DOWN FLAMES OF THE CAR FIRE ( MOSTLY PLASTICS) AND COOL THE SOURCE OF HEAT WITHIN THE BATTERY.
LOW
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE INCIDENT, IF YOU DETECT LEAKING FLUIDS, SPARKS, SMOKE, OR BUBBLING NOISES COMNING FROM THE HIGH-VOLTAGE BATTERY, VENTILATE THE VEHICLE BY?
OPENING WINDOWS AND TRUNK
TB 172
WHEN ASSIGNED TO AN ELECTRONIC VEHICLE FIRE INCIDENT, CONSIDERATION SHOULD BE GIVEN TO ORDERING A ___ ON FREEWAY INCIDENT WHERE A WATER SUPPLY CANNOT BE ESTABLISHED.
WATER TENDER
TB 172
ACCORDING TO THE NFPA, HYBRID AND ELECTRIC VEHICLES ___ SPECIAL EQUIPMENT FOR FIRE SUPPRESSION / EXTINGUISHMENT
DO NOT REQUIRE SPECIAL EQUIPMENT
TB 172
ACCORDING TO THE US FIRE ADMINISTRATION ASSUME VEHICLE IS POWERED- UP. DESPITE NO ENGINE NOISES. CONSIDER THE ELECTRICAL SYSTEM UNSAFE FOR A FULL ____ MINUTES AFTER IGNITION SHUT DOWN.
5 MINUTES
TB 172
ACCORDING TO THE U.S FIRE ADMINISTRATIONS NEVER TOUCH, CUT OR OPEN ANY ___ (COLOR) CABLE OR COMPONENTS PROTECTED BY ORANGE SHIELDS ( HIGH- VOLTAGE).
ORANGE
TB 172
THE BUILDING BLOCK OF A BATTERY IS THE CEL. CELLS MAY BE ___ USE OF RECHARGEABLE
SINGLE
TB 172
A MODULE HAS ____ ASSEMBLED CELL(S)
MULTIPLE
TB 172
A BATTERY PACK FOR AUTOMOBILES WILL HAVE MULTIPLE _____
MODULES
TB 172
BATTERY _____ DESCRIBES ANY MATERIAL WITHIN A CELL THAT COOLS. LUBRICATES & DIFFUSES ENERGY
ELECTROLYTE ( LIQUIDS OR PASTE)
TB 172
OVER TIME ___ SHORTEN LIFESPAN AND EFFECTIVENESS OF A CELL
DENDRITE - CRYSTALS
TB 172
AN ANODE IS THE ____ ELECTRODE INA CELL AND ESSENTIAL PART OF BATTERY
NEGATIVE
TB 172
A ___ IS A POSITIVE ELECTRODE THAT GAINS ELECTRONS RATHER THAN LOSSES THEM
CATHODE
TB 172
THIS SYSTEM HELPS TO MAINTAIN BATTERY HEALTH
BMS
TB 172
A ___ BATTERY IS A SINGLE USE BATTERY. ALKALINE AND SOME ARE LITHIUM
SINGLE USE
TB 172
LITHIUM-ION BATTERY CELLS ARE THE LEADING TECHNOLOGY IN RECHARGEABLE BATTERIES. THEY ARE RECHARGEABLE AND REFEREED TO AS __ BATTERIES
SECONDARY
TB 172
ELECTRON STORAGE FACILITIES. ESS ARE FACILITIES THAT USE ____ CELL TECHNOLOGY
SINGLE
TB 172
LEAD-ACID OR WET-ACID SECONDARY BATTERIES CREATE HYDROGEN GAS, WHICH IS ___ AIR AND HIGHLY FLAMMABLE
LIGHTER
TB 172
LEAD ACID OR WET ACID SECONDARY BATTERIES ARE USED IN CARS AND GOLF CARTS. THEY ARE RECHARGEABLE AND HAVE BEEN USED SINCE 1850’S. THEY CAN LAST ____ YEARS
3-5 YEARS
TB 172
PER THE DEPARTMENT OF TRANSPORTATION, BATTERIES ARE CLASSIFIED AS - DOT CLASS ___
9
TB 172
STANDARD FOR THE INSTALLATION OF STATIONARY ENERGY STORAGE SYSTEMS IS NFPA ____
NFPA 855
TB 179
WHAT IS TB 179
THERE ARE __ TYPES OF GARAGES
RESIDENTIAL GARAGES
3- ATTACHED , DETACHED AND CONVERTED
TB 179
WHAT LOS ANGELES CITY ORDINANCES PRESCRIBES STANDARDS GOVERNING RESIDENTIAL CONVERSIONS
LA - ADU
TB 179
GARAGE FIRE LINE SELECTION. WHILE A ___ LINE MAY BE SUFFICIENT, LARGER LINES SHOULD NOT BE OVERLOOKED WHEN FIRE LOAD AND INVOLVEMENT INDICATE THE NEED FOR MORE VOLUME
1 1/2 “.
TB 179
A “____” OF RESIDENTIAL GARAGE ( NOT TO BE CONFUSED WITH COVERED CARPORTS) IS OFTEN ASSOCIATED WITH APARTMENT COMPLEXES AND BUNGALOW-STYLE DEVELOPMENT
ROW
TB 179
CERTAIN INDICATORS SUCH AS AIR CONDITIONS UNITS, WINDOW CURTAINS AND OR UPGRADED WINDOWS MAY ASSIST MEMBERS IN RECOGNIZING A RESIDENTIAL CONVERSION. A MORE RELIABLE METHOD COULD BE A LACK OF GARAGE DOOR OR THE PRESENCE OF ?
ADDITIONAL ADDRESS INCLUDING 1/2
TB 179
IF A 360 SURVEY IS UNABLE TO BE COMPLETED, THE ASSIGNED OFFICER MUST ATTEMPT TO VISUALIZE AS MUCH OF THE BUILDING AS POSSIBLE ___ COMMUNICATING SIZE UP
BEFORE
TB 179
NEWER TYPE GARAGES, FIRE SPRINKLER & SMOKE DETECTORS ARE GENERALLY ___ BY FIRE CODE
NOT REQUIRED
TB 179
DO ATTACHED OR DETACHED GARAGE BOTH HAVE THE POTENTIAL TO BE CONVERTED
YES, EITHER CAN BE
TB 179
HORIZONTAL VENTILATION CAN BE ACCOMPLISHED BY?
OPEING WINDOWS
CUTTING GARAGE DOOR OPEN
TB 179
COMPANIES OPERATING INSIDE THE RESIDENTIAL PORTION SHOULD MAKE EARLY ACCESS INTO THE ___ TO DETERMINE WHETHER THERE HAS BEEN EXTENSION, AND CLEARY COMMUNICATE THEIR FINDINGS
ATTIC SPACE
TB 180
WHAT IS TB 180
EVERY ONE POUND OF METHAMPHETAMINE GENERATES __ OF MORE POUNDS OF HAZ WASTE
DRUG LABS
- (PTQ)
TB 180
HEROIN , DIACETYLMORPHINE, IS PRODUCED FROM THE ___ BY CHEMICAL PROCESS KNOWN AS ACETYLATION
OPIUM POPPY
TB 180
AN ILLEGAL NARCOTIC LABORATORY OR PRODUCTION HOUSE IS ALSO FREQUENTLY REFERRED TO AS A ?
CLANDESTINE DRUG LABORATORY
TB 180
ONE OF THE MOST POTENT FENTANYL ANALOGUES KNOWN AS CARFENTANIL HAS A POTENCY OF ___ TIMES THAT OF MORPHINE
10,000X
TB 180
PCP OR ANGLE DUST AND KETAMINE ARE MIND ALTERING SUBSTANCES WITH SERIOUS HALLUCINOGENIC EFFECTS. PCP WAS DEVELOPED AS AN ANESTHETIC AND MARKETED UNDER THE NAME “SERNYL” KETAMINE WAS CREATED AS AN ANESTHETIC FOR ANIMALS, AND IS OFTEN KNOWN AS ______
SPECIAL K
TB 180
FENTANLY IS PLANT BASE ?____. IT IS 50 TO 100 TIMES MORE POTENT THAN MORPHINE
NOT PLANT BASED
TB 180
WHEN THE PRESENCE OF FENTANYL IS SUSPECTED. WEAR ?
NIOSH RESPIRATOR MASK
TB 180
WHICH DRUG IS THE PRIMARY DRUG TEAT IN CALIFORNIA?
METHAMPHETAMINE
TB 185
WHAT IS TB 185
THE PROPER FIT OF THE MSA CAIRNS HELMET WOULD PLACE THE FRONT HEADBAND JUST ___ THE EYEBROW AND THE SIDE OF HEADBAND ABOVE EARS
FF HELMET MSA
ABOVE
TB 185
THE MSA CAIRNS HLEMET WEIGHT IS __ POUNDS
3.46 POUNDS
TB 185
THE MSA CAIRNS HELMET CAN RESIST TEMPERATURES UP TO __ DEGREES
500
TB 185
THE MSA CAIRNS HELMET IS MADE UP OF ___ COMPONENTS
10 COMPONENTS
( THE SCBA IS 9 COMPONENTS)
TB 185
THE MSA CAIRNS HELMET MEETS THE NFPA ___ STANDARD
1971
TB 185
MSA CAIRNS HELMET REFLECTIVE TRIM: ___ LIME-GREEN 3M SCOTCHLITE TETRAHEDRONS
8
TB 185 THE MSA CAIRNS HELMET HAS A REPLACEABLE LENS. USE ____ TO REPLACE
SCREWDRIVER
TB 185
THE MSA CAIRNS HELMET CAN BE WASHED USING WARM WATER UNDER 105 DEGREES WITH DETERGENT PH NOT LESS THAN 6.0 OR NOT MORE THAN __ WITH SOFT SPONGE
10.5 PH
TB 185
THE MSA CAIRNS HELMET IF YOU FEEL A GAP BETWEEN HEAD AND HEADBAND LINER, REFER TO
FOAM PAD ADJUSTMENT KIT
TB 185
THE MSA CAIRNS HELMET MEMBERS NAME USE 1” CAPITALIZED REFLECTIVE LETTERS ON TOP SIDE OUTER REAR BRIM, RANKS BELOW CAPTAIN USE ____ REFLECTIVE LETTERS
RED
TB 192
WHAT IS TB 192
FACADES HAVE BEEN USED THROUGHOUT LA FOR OVER __ YEARS
FACADE HAZARD
75 YEARS
TB 192
FACADE MEANS ALL THE FOLLOWING (4)
FACE OF A BUILDING
SUPERFICIAL
ARTIFICIAL APPEARANCE
FALSE
(NOT TRUE FONT)
TB 192
INTERCHANGEABLE NAMES FOR FACADE INCLUDE ALL THE FOLLOWING NAMES ( 4)
MANSARD
EYEBROW
AWNING
OVERHANG
(NOT INTERNAL FACE)
TB 192
FACADE WHEN SUPPORTED WITH POST ARE ______
STILL HAZARDS
TB 192
FACADE HEIGHT AND SHAPE WILL AFFECT BY WHAT 3
STABILITY
MATERIAL USED
POTENTIAL PATH OF FIRE TRAVEL
TB 192
STUCCO IS A COMMON FINISH FOR FACADES. STUCCO WEIGHTS __ POUNDS PER SQUARE FEET
100
TB 192
THE FACADE COLLAPSE ZONE IS ___ TIMES THE HEIGHT OF THE FACADE
1 1/2 X
TB 192
FACADE COLLAPSE IN VARIOUS WAYS. ALL THE FOLLOWING WAYS ARE (3)
INWARDS
OUT WARDS
STRAIGHT DOWN
(NOT INWARD DIAGONAL NOT A TERM)
TB 195
WHAT IS TB 195
THE MSA SCBA IS CERTIFIED BY NFPA 1981 1982 AND ____
MSA SCBA
NIOSHA
TB 195
THE MSA SCBA LACK OF MOVEMENT BY THE USER FOR ____ SECONDS WILL ACTIVATE A LIGHT EMITTING DIODE (LED). LIGHTS FLASHING RED. ALARM INCREASING IN STAGES UNTIL FULL ALERT AT 30 SECONDS
20 SECONDS
TB 195
THE MSA G1 SCBA INCLUDES A “CENTRAL POWER” FEATURE THAT POWERS THE ENTIRE UNIT FROM ___ RECHARGEABLE BATTERY(IES)
1
TB 195
THE MSA SCBA AIR CYLINDER HOLDS ___ CUBIC FT. OF BREATHING AIR
66
TB 195
THE DOVETAIL INTERLOCKING SYSTEM PREVENTS BOTTLE ROTATION. A QUICK CONNECTION FOR EASY HOOKUP. TO REMOVE THE CYLINDER, TURN HAND WHEEL A __ TURN AND SQUEEZING QUICK CONNECTION WHILE PULLING AWAY FROM THE CYLINDER
1/4
TB 195
THE MSA SCBA CARRIER FROM HAS 3 BUILT IN CARRYING HANDLES. THE SIDE HANDLES ARE RATED AT _____
THE TOP HANDLES ARE RATED AT _____. STATIC FORCE
500 POUNDS
1000 POUNDS
TB 195
THE MSA SCBA UNIVERSAL AIR CONNECTION - UAC IS USED IN EMERGENCIES BY RIC COMPANIES FOR BOTTLE QUICK FILL. WHEN AIR PRESSURE IS AT ___ PSI OR 35% A WHITE LIGHT WILL ILLUMINATE THE UAC FITTING TO ASSIST IN LOCATING
1575 OR 35 %
TB 195
MSA SCBA THE UNIVERSAL EMERGENCY BREATHING SAFETY SYSTEM ( UEBSS) Y- BLOCK IS A ___ INCH INTERMEDIATE PRESSURE HOSE WITH MALE AND FEMALE QUICK CONNECTION FITTINGS
39” LONG
TB 195
THE MSA SCBA FIRST STAGE PRESSURE REDUCER AND LOW AIR WARNING DEICE. THE VALVE LOWERS AIR CYLINDER PRESSURE TO ___ PSI, WHICH SUPPLIES TO THE SECOND STAGE REGULATOR VIA AN INTERMEDIATE HIGH PRESSURE HOSE
115
TB 195
THE MSA SCBA FACE PIECE IS NFPA COMPLAINT AND HAS A POLYCARBONATE LENS THAT PROVIDES HEAT PROTECTION OF ___ DEGREES FOR 5 MINS
500 DEGREES
TB 195
THE MSA SCBA LITHIUM-ION BATTERY DESIGNED TO LAST FOR ___ HOURS OF CONTINUOUS USE
6-8 HOURS