Traction Flashcards
How many vehicles are in a class 455 formation?
4 cars per unit
Whst is the maximum speed of a class 455 train?
Maximum speed 75mph.
What is the length of a class 455 coach?
Length of a 455 coach is 20 meters.
How many traction motors does a class 455 has per Motor Coach?
A class 455 has X4 250HP traction motors per Motor Coach.
What is the maximum formation of only class 455 units that can be coupled together?
Maximum total formation of only class 455 units is a total of X8 coaches in the formation.
What type of coupler does a class 455 unit have?
External identification
A class 455 has a tight lock coupler
What is the maximum formation made up of class 455 + 456 traction units?
Maximum length formation of class 455 + 456 traction units is 10 coaches.
What other traction units may a class 455 fully couple to?
A class 455 traction unit may fully couple to other class 455 units and class 456 units.
What addition equipment is needed to mechanically couple to a 444/450 traction unit?
What is the maximum speed after coupling and why?
You will require an Emergency Coupling Adapter. Maximum speed allowed after coupling is 5mph, due to only being mechanically coupled and not additionally electrically coupled.
What does these terms mean in regards to the individual coaches
- DT A
- MC
- NDT
- DT B
Coach identifying names
- Driving Trailer A
- Motor Coach
- Non Driving Trailer
- Driving trailer B
What is the name of these 2 items on the class 455 traction unit?
455 external identification
- 1 = 42 way control jumper (oragne). Provides electrical power.
- 2 = Main reservoir pipe & main reservoir isolation cock (yellow)
External identification Class 455
What is the name of item 1 on this class 455 traction unit?
What position is A & B?
External identification Class 455
- 1 = Drumswitch
- A = Coupled
- B = Uncoupled
External Identification Class 455
What is the name of this item?
What 3 outputs does it produce?
External identification Class 455
The motor alternator runs continuously when the unit is cut in and produces 3 outputs used as follows:
- 415 volts A.C. Heating fans (including cab fans)
- 240 volts A.C. Lighting
- 110 volts A.C. Control circuits, Battery charging, Emergency lighting
As the 110 volt supply needs to be DC, it is passed through a rectifier which changes it from alternating current (A.C.) to direct current (D.C.)
Motor alternator failure Class 455
If the MA fails and the battery takes over, how many volts does it need to drop below before the unit cuts out?
Motor alternator failure Class 455
If the MA fails, the batteries will take over but will only supply 110 DC volts for the control circuits and emergency lighting. When the battery voltage drops below 80 volts the unit will automatically cut out.
If this happens, assistance will be required whereupon after coupling up all the pipes and jumpers, you will need to cut the defective unit in again using the aux set button on the good unit.
Motor alternator failed indication Class 455
What indications will you get if the motor alternator fails?
Motor alternator failed indication Class 455
- Only one marker / tail light
- No main lights
- No cab fans
- MA fault indicator illuminated (Red light)