Topic Quiz, 16-Hour Plumbing Systems Flashcards
[TEST QUESTION]
Shield plates required to protect piping installed through notches or bored holes in framing members shall extend a minimum of ____ above sole plates & below top plates.
a. 1/2’’
b. 1’’
c. 2’’
d. 3’’
c. 2’’
[IRC P2603.2.1]
[TEST QUESTION]
Unless provided with a relieving arch, a building drain passing through a foundation wall shall pass through a pipe sleeve sized ___ greater than the pipe passing through.
a. 1’’
b. 2’’
c. 1 pipe size
d. 2 pipe sizes
d. 2 pipe sizes
[IRC P2603.4]
[TEST QUESTION]
Standpipes shall extend a minimum of ____ & a maximum of _____ above the trap weir.
a. 18’’, 30’’
b. 18’’, 42’’
c. 24’’, 30’’
d. 24’’, 42’’
b. 18’’, 42’’
[IRC P2706.2]
[TEST QUESTION]
The outlet of a laundry tray shall be a maximum horizontal distance of ____ from the standpipe trap.
a. 18’’
b. 30’’
c. 42’’
d. 60’’
b. 30’’
[IRC P2706.2.1]
[TEST QUESTION]
Shower compartments shall have a minimum interior cross-sectional area of _____.
a. 900 sq in
b. 1,080 sq in
c. 1,296 sq in
d. 1,440 sq in
a. 900 sq in
[IRC P2708.1]
[TEST QUESTION]
The curb for a shower receptor shall have a minimum depth of ____ & a maximum depth of ____ when measured from the top of the curb to the top of the drain.
a. 1’’, 6’’
b. 1’’, 9’’
c. 2’’, 6’’
d. 2’’, 9’’
d. 2’’, 9’’
[IRC P2709.1]
[TEST QUESTION]
A Lavatory shall have a waste outlet a minimum of ____ in diameter.
a. 1’’
b. 1 1/4’’
c. 1 1/2’’
d. 2’’
b. 1 1/4’’
[IRC P2711.3]
[TEST QUESTION]
Unless an approved alternative is provided, flush valve seats for flushing water closets shall be a minimum of ___ above the flood level rim of the bowl to which it is connected.
a. 1/2’’
b. 1’’
c. 1 1/2’’
d. 2’’
b. 1’’
[IRC P2712.4]
[TEST QUESTION]
Bathtubs shall have outlets & overflows a minimum if ____ in diameter.
a. 1’’
b. 1 1/4’’
c. 1 1/2’’
d. 2’’
c. 1 1/2’’
[IRC P2713.1]
[TEST QUESTION]
Sinks shall have a waste outlet a minimum ___in diameter.
a. 1 1/4’’
b. 1 1/2’’
c. 2’’
d. 3 1/2’’
b. 1 1/2’’
[IRC P2714.1]
SOP: Minimum Inspection Requirements for Plumbing Systems
a. §535.231
b. §535.232
c. §535.230
d. §535.233
a. §535.231
[TEST QUESTION]
Food waste grinders shall be connected to a drain having a minimum diameter of _____ .
a. 1 1/4’’
b. 1 1/2’’
c. 2’’
d. 3 1/2’’
b. 1 1/2’’
[IRC P2716.1]
[TEST QUESTION]
Floor drains shall have waste outlets a minimum of ____ in diameter.
a. 1 1/4’’
b. 1 1/2’’
c. 2’’
d. 3 1/2’’
c. 2’’
[IRC P2719.1]
[TEST QUESTION]
What is the minimum size drain required for a macerating toilet system?
a. 3/4’’
b. 1 1/4’’
c. 1 1/2’’
d. 2’’
a. 3/4’’
[IRC P2723.2]
[TEST QUESTION]
Trenches used for the installation of piping that are excavated parallel to footings shall extend a maximum of ____ below the bearing plane of the bottom edge of the footing.
a. 30-deg
b. 45-deg
c. 12’’
d. 30’’
b. 45-deg
[IRC P2604.4]
[TEST QUESTION]
There shall be a minimum ____ clearance in front of a water closet, to any wall, fixture or door.
a. 18’’
b. 21’’
c. 24’’
d. 27’’
b. 21’’
[IRC P2705.1(5)]
[TEST QUESTION]
in general, fuel fired appliances are permitted to be located in which one of the following spaces?
a. Sleeping rooms
b. Storage closets
c. Bathrooms
d. Garages
d. Garages
[IRC G2406.2]
[TEST QUESTION]
Where located in a hazardous location, equipment & appliances having an ignition source shall be elevated such that the ignition source is located a minimum of ___ above the floor.
a. 6’’
b. 12’’
c. 18’’
d. 30’’
c. 18’’
[IRC M1307.3]
[TEST QUESTION]
Unless protected from motor vehicle damage, appliances located in private garages shall be installed with a minimum clearance of ____ above the ground.
a. 60’’
b. 72’’
c. 80’’
d. 84’’
b. 72’’ (6’)
(Quizlet)
[IRC G2408.3]
[TEST QUESTION]
In general, underground gas piping shall be installed a minimum depth of _____ below grade.
a. 6’’
b. 12’’
c. 18’’
d. 24’’
b. 12’’
[IRC G2415.12]
[TEST QUESTION]
The unthreaded portion of gas piping outlets shall extend a minimum of ____ through finished ceilings & walls.
a. 1’’
b. 2’’
c. 3’’
d. 4’’
a. 1’’
[IRC G2415.16]
[TEST QUESTION]
The tracer wire required adjacent to underground non-metallic gas piping shall be a minimum of _____ wire size.
a. 14 AWG
b. 16 AWG
c. 18 AWG
d. 20 AWG
c. 18 AWG (Yellow-CU)
[IRC G2415.17.3]
[TEST QUESTION]
A gas shutoff valve for an appliance shall be located in the same rooms as the appliance, with a maximum distance of ____ between the valve & the appliance.
a. 3’
b. 4’
c. 6’
d. 10’
c. 6’
[IRC G2420.5.1]
[TEST QUESTION]
Gas fired equipment & appliances, where suspended above grade level, shall provided with a minimum clearance of _____ from the adjoining grade.
a. 2’’
b. 4’’
c. 6’’
d. 8’’
c. 6’’
[IRC G2408.4]
[TEST QUESTION]
Fuel gas piping installed across a roof surface shall be elevated above the roof a minimum of :
a. 1 1/2’’
b. 2’’
c. 3 1/2’’
d. 6’’
c. 3 1/2’’
[IRC G2415.9]
[TEST QUESTION]
1’’ (O.D.) smooth-wall tubing used a fuel gas piping shall be supported at maximum intervals of:
a. 4’
b. 6’
c. 8’
d. 10’
c. 8’
[IRC G2424.1]
[TEST QUESTION]
Where the termination for a drain pan for a water heater extends to the exterior of the building, it shall terminate a minimum of ____ & a maximum of ____ above the adjacent ground surface.
a. 3’’, 12’’
b. 3’’, 24’’
c. 6’’, 12’’
d. 6’’, 24’’
d. 6’’, 24’’
[IRC P2801.5.2]
[TEST QUESTION]
A water heater pressure relief valve shall be set to open at least ____ above the system pressure but not over ____ .
a. 15 psi, 125 psi
b. 15 psi, 150 psi
c. 25 psi, 125 psi
d. 25 psi, 150 psi
d. 25 psi, 150 psi
[IRC P2803.3]
[TEST QUESTION]
A water heater temperature relief valve shall be set to open at a maximum temperature of :
a. 150F
b. 165F
c. 180F
d. 210F
d. 210F
[IRC P2803.4]
[TEST QUESTION]
Where located close to a wall, what is the minimum required air gap for a lavatory with an effective opening of 1/2’’?
a. 1’’
b. 1 1/2’’
c. 2’’
d. 3’’
b. 1 1/2’’
[IRC P2902.3.1]
[TEST QUESTION]
Approved deck mounted vacuum breakers shall be installed with the critical level a minimum of _____ above the flood level rim.
a. 1’’
b. 2’’
c. 4’’
d. 6’’
a. 1’’
[IRC P2902.4.2]