Systems Test 6 Flashcards
- LOT 202.23 OL-ACW*
- *
Which loads have auto TCV’s?
Gen H2 cooler (1)
Turbine Lube Oil Coolers (2)
SGFPT Lube Oil Coolers (6)
Gen H2 Cooler TCVs controlled on CP007.
- LOT 202.15 SGWLC*
- *
How does the LPRVs control SGWL?
- SG Water Level Mismatch:*
- *Actual Level - Program Level**
- PR NI Compensation:*
- *Auctioneered High NI**
Low Power Feed Reg Valves are level dominant.
- LOT 202.22 Circulating Water*
- *
What will auto start the CW Screen Wash Pumps?
Lead Pump:
Screen D/P > 6”
One Screen Running
First Lag Pump:
10 Sec after lead pump start, Pressure < 102 psig
4 Screens Running
Second Lag Pump:
10 Sec after 1st lag pump start, Pressure < 102 psig
7 Screens Running
If pump started on low pressure will not stop. (Must reset)
Note:
Spray valves will open when pressure > 90 psig
- LOT 202.22 Circulating Water*
- *
What will energize the blue start permissive light on CP009?
Discharge Column filled*
- *Seal Pressure > 30 psig**
- < 50 psig starts standby pump*
Discharge Valve Closed
> 5 mins since last CW pump start
Can use Jet pump to draw air and moisture out of CW discharge column.
- Uses screen wash header as prime water
- LOT 202.15 SGWLC*
- *
How does the SGFPTs control SGWL?
- Pressure Mismatch:*
- *Actual D/P - Reference D/P**
- Actual D/P:*
- *Feed Pressure (PT-558) - Steam Pressure (PT-557)**
- Reference D/P:*
- *0% - 20% Steam Flow: 65 psid**
- *100% Steam Flow: 169 psid**
- Goes up linearly from 20% - 100%*
- PT-558 (Common Header Feed Pump Discharge Pressure)
- PT-557 (MS Equalizing Header)
- Same as steam dumps
Note:
Steam flow is the selected steam flow channel on CP006.
- LOT 202.28 AFW*
- *
What level in the AFWST requires the operators to enter FLEX?
- Loss of All AC Power:*
- *< 164,000 gals**
- LOT 201.29 Fire Protection*
- *
If the fire protection pump auto starts, what is the only thing that will trip the pump?
Mechanical Overspeed
Applies if pumps start on Low Header Pressure, Loss of power, or remote start from either control room. (CP018)
Note:
Cannot be stopped from control room.
- LOT 202.24 CL-ACW*
- *
What will auto start/trip the CL-ACW pumps?
Auto Starts:
Discharge Header Pressure - Low (60 psig)
Trip of running pump
- Trips:*
- *Ground Fault**
Overcurrent
Undervoltage
Controlled from CP009/Local
Note:
SW/FW HX Common discharge pressure on CP009 NOT pump discharge pressure.
- LOT 201.40 AMSAC*
- *
When will AMSAC actuate?
SGNR Level ≤ 15% [1/1 on 3/4] [25 sec TD]
Initiates:
- Turbine Trip
- Aux Feed Actuation
- Blowdown Isolation
- SG Sampling Isolation
Note:
Armed if ≥ C-20 (≥ 30% Impulse Pressure) [2/2] ≈ 40% RTP
- Peak pressure not a concern if < 70% RTP
- Stays armed for 360 sec after falling below 30% impulse pressure
- LOT 202.24 CL-ACW*
- *
What does CL-ACW cool?
Turbine:
EHC (120 ˚F)*
Air Side Seal Oil (105 ˚F)*
H2 Side Seal Oil (105 ˚F)*
Exciter Coolers (113 ˚F)*
Isophase
Stator Cooling Water (105 ˚F)*
Feed / Condensate:
Condensate Pump Bearings
Feed Booster Pump Bearings / Lube Oil
SUFW Seals / Lube Oil*
TCV closes at low temps
Misc:
IA Compressors (11/12/13)
After Cooler / Lube Oil
Secondary Sampling
MSDT pumps Seal Water
CARS
Note:
Coolers have automatic TCVs
- LOT 202.20 Stator Cooling Water*
- *
What D/P across the stator will trip the turbine?
Stator Cooling Water D/P - Low (19 psid) [2/3] [40 sec TC]
Will get alarm in ZLP-150 (Basement Shelter) after 10 sec [1/3]
Note:
This is D/P across the stator. Do not confuse with D/P across the running pump. (Auto Start of standby SCW pump)
- LOT 202.22 Circulating Water*
- *
What is the CW pump start sequence?
- First Pump:*
- *10 sec after start, Discharge MOV opens to 40%**
- Second Pump:*
- *10 sec after start, 2nd Pump’s Discharge MOV fully opens**
Once 2nd Pump’s Discharge MOV is 35% open, 1st Pump’s Discharge MOV fully opens
- Third / Fourth Pump:*
- *10 sec after start, Discharge MOVs fully open**
Pump trips:
- Discharge MOV NOT moving after 24 sec
- Discharge MOV NOT 35% open in 32 sec
- LOT 202.20 Stator Cooling Water*
- *
What stator cooling water parameters would cause the operators to manually trip the reactor and turbine if > P-9?
- *SCW D/T - High (≥ 21.5 ˚F)**
- U5524 / U5525*
- *SCW Temperature - High (194 ˚F)**
- U5520 / U5521*
- LOT 202.12 FW Heaters / Drips/ Vents*
- *
What are the influents/effluents of HP Htr 11A/B?
Influents:
RHDT’s
HP Turb 4th Stage
MSR Vent Chamber
- Effluents:*
- *Deaerator**
- LOT 202.23 OL-ACW*
- *
What does OL-ACW cool?
Main Turbine Lube Oil (2)
SGFPT Lube Oil (6)
Generator H2 (1)
CL-ACW (2)
RCB Chillers (3)
MAB Chillers (4)
- LOT 202.28 AFW*
- *
What will auto start the AFW pumps?
- Motor Driven:*
- *SG Level - Low 2 (20%) [2/4 on 1/4]**
AMSAC (15%) [1/1 on 3/4] [25 sec TC]
- *Sequencers (MODE I,II,III)**
- MODE II starts pump but valves do NOT open*
- Turbine Driven:*
- *SG Level - Low 2 (20%) [2/4 on 1/4]**
AMSAC (15%) [1/1 on 3/4] [25 sec TC]
SI
Regulating Valves throttle and OCIVs open for:
- SG Level - Low 2 (20%) [2/4 on 1/4]
- AMSAC (15%) [1/1 on 3/4] [25 sec TC]
- SI
- LOT 202.28 AFW*
- *
What are the design bases for the AFW system?
- Automatic Operation:*
- *Starts within 1 min and can run unattended for 10 mins**
- Flowrate:*
- *Supplies 500 gpm to 1 S/G for FW Rupture / SLB**
Supplies 500 gpm to 2 S/Gs for loss of FW / LOOP
- Cooldown:***
- *50 ˚F/hr with 1 RCP**
25 ˚F/hr on natural circ
- AFWST:***
- *Maintain plant in hot standby for 4 hrs and then go to RHR conditions**
- Containment Integrity:*
- *Prevents reaching containment design pressure (56.5 psig)**
- Note:*
- Showed up on instructor’s NRC exam*