Systems Test 2 Flashcards
- LOT 201.06 CVCS*
- *
What will generate a letdown valves sequence incorrect alarm?
Shutting MOV-465 OR MOV-468 prior to FV-011
Switches located on CP004.
- Note:*
- FV-011 shuts first to prevent water hammer in the regenerative HX.*
- LOT 201.06 CVCS*
- *
At what pressure will the VCT relief valve (CV-3101) lift?
75 psig
Relieves to the RHT.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 1?
Power Operation:
- Keff:*
- *≥ 0.99**
- RTP:*
- *> 5%**
- Tavg:*
- *≥ 350 ˚F**
- LOT 202.32 RCB Chilled Water*
- *
With regards to the RCB Chilled Water system, what happens during a SI or a LOOP?
- RCFC Chilled Water OCIVs:*
- *Close on SI OR LOOP**
- RCFC CCW OCIVs:*
- *Open on SI**
- *Remain Closed on LOOP**
- Operators must open them (30 min req. [EOPs])*
RCFC CCW OCIVs will NOT open unless Chilled Water OCIVs shut.
- Note:*
- If SI and LOOP happen concurrently, SI wins and CCW OCIVs open.*
- LOT 201.04 PZR, PRT, & RCDT*
- *
Where does the RCDT relief valve relieve to?
Containment Normal Sump
- LOT 201.41 ESF Load Sequencer*
- *
Plant Conditions:
- ESF DG in parallel with offsite
- SI occurs
What does the ESF DG load sequencer do?
Output bkr will open and then MODE I will occur
If output bkr does not trip within 1 sec, incoming breaker will trip, sequencer will strip bus w/ exception of LC breakers and MODE III sequence will run.
- LOT 201.05 RCPs*
- *
What is the pressure, flowrate, and flowpath of the #1 Seal?
- Pressure:*
- *2250 psig → 30 psig**
- Min D/P: 220 psid*
- Flowrate:*
- *8 gpm → 3 gpm**
- Suction:*
- *CVCS**
- Discharge:*
- *VCT ****
- CCP Suction*
- *Seal #2**
Inlet temperature ≈ 110 ˚F (Do not exceed 230 ˚F)
≈ 5 gpm goes to pump radial bearing and thermal barrier HX
Note:
On ΦA CI, Seal return to VCT isolates and relief will lift (150 psig) to send water to PRT.
- LOT 201.02 RCS*
- *
What are the piping penetrations off the hot legs?
- Loop 1:*
- *RHR “A” Suction**
- *SI “A” Recirc**
- *Sampling**
- Loop 2:*
- *RHR “B” Suction**
- *SI “B” Recirc**
- Loop 3:*
- *RHR “C” Suction**
- *SI “C” Recirc**
- *Sampling**
- Loop 4:*
- *PZR Surge Line**
- LOT 201.06 CVCS*
- *
With regards to LT-112 and LT-113, how is level controlled in the VCT?
- 95%*
- *112A Full Divert**
- LT-112 AND LT-113*
- *Alarm**
- LT-113*
- 68% - 95%*
- *112A modulates diverting to RHT**
- LT-112*
- 48%*
- *Stops Auto M/U**
- LT-112*
- 28%*
- *Starts Auto M/U**
- LT-112*
- 15%*
- *Alarm**
- LT-112 AND LT-113*
- 3%*
- *Shifts CCP suction from VCT to RWST (112C / 113B)**
- *Isolates VCT outlet (112B / 113A)**
- LT-112 AND LT-113*
- LOT 201.20 SSPS*
- *
Which actuation train’s urgent alarm will result in a logic train’s urgent alarm?
Actuation Train “A” → Logic Train “R”
Actuation Train “B” → Logic Train “S”
Actuation Train “C” does NOT result in a logic train’s urgent alarm.
Actuation Train “C” trouble alarm does result in a Logic Train “R” AND Logic Train “S” trouble alarm.
- Note:*
- Urgent alarms on CP026.*
- LOT 201.06 CVCS*
- *
What will close the letdown CIVs (CV-023 / CV-024)?
- *CI ΦA**
- *High Energy Line Break**
- 112.7 ˚F [1/8] in MAB room shuts associated valve*
- LOT 201.06 CVCS*
- *
What will automatically close the VCT outlet isolation valves (MOV-112B/MOV-113A)?
- MOV-112B AND MOV-113A*
- *SI**
- Opens MOV-112C AND MOV-113B*
- MOV-112B*
- *VCT Level - Low 2 (3%) [LT-112]**
- Opens MOV-112C*
- MOV-113A*
- *VCT Level - Low 2 (3%) [LT-113]**
- Opens MOV-113B*
To ensure CCPs have suction water at all times, RWST supply valves (MOV-112C/MOV-113B) must be full open to close respective VCT Outlet valve (MOV-112B/MOV-113A).
- Note:*
- Holding the manual switches for the valves (112B/C and 113A/B) will override any auto functions and the valves will position as selected.
- Located on CP004.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 4?
Hot Shutdown:
- Keff:*
- *< 0.99**
- RTP:*
- *0%**
- Tavg:*
- *350 ˚F > Tavg > 200 ˚F**
- LOT 201.06 CVCS*
- *
When will the letdown temperature divert valve (TCV-143) automatically bypass the demins?
Letdown HX Discharge Temp - High (137 ˚F)
OR
BTRS Demin Inlet Temp - High (157 ˚F)
Located on CP004
- Note:*
- Loss of Air/voltage fails to divert.*
- LOT 201.05 RCPs*
- *
What must pressure in the bearing oil lift system be in order to start a RCP?
600 psig
- Blue permissive light on CP005
- Bearing Oil pump must be running to start pump. (Not required for light however)
- Must be operated for ≥ 2 mins by procedure prior to starting RCP.
- LOT 201.41 ESF Load Sequencer*
- *
What is the MODE III sequence of starting loads?
- 1 Sec:*
- *480 V Buses**
- 6 Sec / 10 Sec:*
- *HHSI / LHSI**
- 15 Sec:*
- *Containment Spray** (1st Try)
- *RCFC (11/12)**
- 20 Sec / 25 Sec:*
- *CCW / ECW**
- 30 Sec:*
- *AFW**
- 35 Sec:*
- *CR / EAB HVAC (Emergency MODE)**
- *Essential Chilled Water Pump**
- *Standby Essential Chiller**
- 40 Sec:*
- *Containment Spray** (2nd Try / Locks in)
- 240 Sec:*
- *Running Essential Chiller(s)**
- 280 Sec:*
- *Sequence Complete**
- LOT 201.41 ESF Load Sequencer*
- *
What is the MODE I sequence of starting loads?
- 6 Sec / 10 Sec:*
- *HHSI / LHSI**
- 15 Sec:*
- *Containment Spray** (1st Try)
- *RCFC (11/12)**
- 20 Sec / 25 Sec:*
- *CCW / ECW**
- 30 Sec:*
- *AFW**
- 35 Sec:*
- *CR / EAB HVAC (Emergency MODE)**
- *Essential Chilled Water Pump**
- *Standby Essential Chiller**
- 40 Sec:*
- *Containment Spray** (2nd Try / Locks in)
- 240 Sec:*
- *Running Essential Chiller(s)**
- 280 Sec:*
- *Sequence Complete**
- LOT 201.15 RCS Temperature Monitoring*
- *
What are the RCS NR temperature instruments used for?
- Tavg:*
- *OT∆T**
- *OP∆T**
- *FW Isolation**
- P-4 w/ Tavg - Low (574 ˚F)*
- *P-12**
- < 563 ˚F [2/4] Blocks steam dumps*
- Auctioneered High Tavg:*
- *Rod Control**
- Indication on CP005 is Auctioneered Low Tavg*
- *Steam Dumps**
- *PZR Level Control**
- Auctioneered Low Tavg:*
- *C-17**
- Auctioneered High ∆T:*
- *Rod Insertion Limit**
3 in HL (120˚ apart for laminar flow concerns) and 1 in CL per loop.
Also has 3 fast response RTDs in CL per loop.
- Note:*
- 3 HL RTDs are averaged together to give signal. If 1 fails the system will automatically kick it out.*
- LOT 201.02 RCS*
- *
What size are the pipes in the RCS?
- Cold Leg:*
- *27.5”**
- Hot Leg:*
- *29”**
- Bigger than cold leg to accommodate expansion of coolant.*
- Intermediate Leg:*
- *31”**
Inside Diameter of pipes.
- LOT 201.15 RCS Temperature Monitoring*
- *
What are the RCS WR temperature instruments used for?
PAMS
- *COMS**
- Auctioneered Low Tc (PCV-656A) and TH (PCV-655A)*
H/U and C/D
Aux S/D Panel
1 in HL and 1 in CL per loop.
- Note:*
- Located on CP018 and ICS
- ASP for TC only.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 2?
Startup:
- Keff:*
- *≥ 0.99**
- RTP:*
- *≤ 5%**
- Tavg:*
- *≥ 350 ˚F**
- LOT 201.02 RCS*
- *
What are the piping penetrations off the cold legs?
- Loop 1:*
- *PZR Spray**
- *SI Train “A” Injection** / RHR “A” Return
- Same Penetration*
- *Normal Charging**
- Loop 2:*
- *SI Train “B” Injection** / RHR “B” Return
- Same Penetration*
- Loop 3:*
- *SI Train “C” Injection** / RHR “C” Return
- Same Penetration*
- *CVCS Alternate Charging**
- Loop 4:*
- *PZR Spray**
- LOT 201.02 RCS*
- *
What would Loop 1 RCS flow indicate if the high pressure tap on loop 1 ruptures?
All loop flows in that loop fail to zero
Loop flow consists of 1 High Pressure (Outside of elbow) and 3 Low Pressure (Inside of elbow).
↓∆P = ↓HP - LP → Flow ↓
Note:
Rupture of a Low pressure tap would result in Flow failing high on 1 of 3 flow instruments.
- LOT 201.02 RCS*
- *
What is Keff, RTP, and Tavg when the plant is in MODE 6?
Refueling:
- Keff:*
- *≤ 0.95**
- RTP:*
- *0%**
- Tavg:*
- *≤ 140 ˚F**
Fuel in the Rx vessel w/ vessel closure bolts less than fully tensioned or head removed.