Section III: General Standard Operating Guidelines Flashcards
Section III: General Standard Operating Guidelines
What will the 5th (extra) firefighter on the Truck be referred to as?
Outside Vent Firefighter
Section III: General Standard Operating Guidelines
An engine must be on _________ on a commercial fire.
A hydrant
Section III: General Standard Operating Guidelines
The Captain is responsible for supervising ______ ________ along with providing for interior communications with the IC and other companies regarding interior operations.
Interior operations
Section III: General Standard Operating Guidelines
______ will be in place anytime we are engaged in interior fire attack regardless of a rescue.
2OUT
Section III: General Standard Operating Guidelines
The ________ is responsible for proper placement of the Truck once on-scene.
Captain
Section III: General Standard Operating Guidelines
With the 2nd truck splitting with the captain and engineer outside, this will also ensure that both ______ _______ are outside with their respective apparatus.
Truck engineers
Section III: General Standard Operating Guidelines
Fire apparatus shall have a rated capacity of ______ GPM or greater for use in interior structural fire attack.
750
Section III: General Standard Operating Guidelines
The SFD will operate in a consistent manner by applying FIRESCOPE, NIMS/SIMS and ICS principles while using sound ______ ______ __ ________ in conjuction with the department SOGs.
Sound firefighting principles and practices
Section III: General Standard Operating Guidelines
What are the 3 different priorities that we operate in?
Life, Property, Environment
Section III: General Standard Operating Guidelines
Gas venting from ____ ______ creates the highest level of danger due to the potential for ignition from static electricity discharge.
Plastic lines
Section III: General Standard Operating Guidelines
Can fire personnel authorize re-occupancy following a gas leak?
No
Section III: General Standard Operating Guidelines
Most building’s FDCs are located on the _______ of the systems fire pump
discharge-side
Section III: General Standard Operating Guidelines
Tandem pumping produces greater pressures while still maintaining ________.
volume
Section III: General Standard Operating Guidelines
Pre-connected lines should be in operation within ______ of arrival.
One minute
Section III: General Standard Operating Guidelines
In regards to a MAYDAY, Company officers and their crew must _____ with their assigned fireground task and not ______ firefighting positions.
Continue; abandon
Section III: General Standard Operating Guidelines
The “Evacuation Signal” will consist of ______ _____ _______ of the air horn for a period no longer than __ seconds, followed by __ seconds of silence, done 3 times.
Repeated short blasts; 10; 10
Section III: General Standard Operating Guidelines
1 Engine, 1 Truck, 1 Rescue and 1 Command unit is what level RIC.
Level III
Section III: General Standard Operating Guidelines
All interior fire attack operations will be backed-up outside the IDLH by a minimum of ___ ________ at all times.
2 firefighters
Section III: General Standard Operating Guidelines
Never use _____ on a mailbox fire.
water
Section III: General Standard Operating Guidelines
What length ladder will reach most elevated roadways.
35 foot
Section III: General Standard Operating Guidelines
At ALS Standby at critical law enforcement incidents, the chief officer assigned will become the “______ ______” in the law enforcement command structure.
Agency Representative
Section III: General Standard Operating Guidelines
What is the minimum size for a landing zone for a helicopter?
100’ x 100’ level area
Section III: General Standard Operating Guidelines
The fire company shall self dispatch for a citizen walk in report of emergency when?
If the emergency is in the immediate district
Section III: General Standard Operating Guidelines
You must notify law enforcement anytime the deceased is how old? (and not in a medical care facility)
18 years or younger
Section III: General Standard Operating Guidelines
On vehicle fires, what should be opened and visually inspected?
All vehicle compartments
Section III: General Standard Operating Guidelines
Purge the work area (of a structure fire), prior to overhaul, a rule of thumb is at least ___ minutes duration for purging.
15
Section III: General Standard Operating Guidelines
For a safely surrendered baby, the baby should be _____ old or younger and cannot show any signs of _____ or ______.
3 days; neglect; abuse
Section III: General Standard Operating Guidelines
In discovering another incident while en route to a dispatched incident, who’s discretion is it to operate at the discovered incident.
The Captain
Section III: General Standard Operating Guidelines
The communications plan should be initiated from the ________ ___ as the incident expands.
Bottom up
Section III: General Standard Operating Guidelines
In regards to Lock Outs, the Hold Harmless and Waiver of Claim, Form F-33, how long shall the form be retained by the department.
A period of one year