Engine Company Handbook Flashcards
Engine Company Handbook
All Sacramento Fire engine apparatus meet the specifications and standards as outlined by the NFPA __________________.
1901-Standard for Automotive Fire Apparatus
Engine Company Handbook
Sacramento Fire engines have permanently mounted centrifugal fire pumps which can produce up to __________ their rated capacity with adequate water supply from a hydrant.
twice
Engine Company Handbook
Securing a water supply is a top priority but does not supersede the need to establish an ___________________.
interior attack hose line
Engine Company Handbook
The hose beds on a Sacramento Fire engine are configured to perform both ________ and __________ operations.
supply / fire attack
Engine Company Handbook
Each engine has two ___ inch intakes equipped with a ball-intake valve.
6
Engine Company Handbook
All engines have a permanently mounted fire pump with a rated discharge capacity of at least ____ gpm.
1,000
Engine Company Handbook
On a Type VI unit, how many gallons does the water tank hold?
400
Engine Company Handbook
How much 3” hose is in a flat load on a Type 1 engine?
600
Engine Company Handbook
The primary mission of an engine is to provide ______ ________ for fire streams.
adequate pressure
Engine Company Handbook
The Dash class engine is outfitted with a ________ pump, while the Velocity and the Enforcer classes are outfitted with a _______ pump
two-stage / single stage
Engine Company Handbook
All of the hose used by Sacramento Fire meets the requirements set forth by the NFPA _________.
1961-Standard on Fire Hose
Engine Company Handbook
In the three-inch hose bed, small hand loops will be placed every _______ on the _______ stack.
50’ / right
Engine Company Handbook
The primary causes of damage to fire hose are _______, _______, and ________.
mechanical / thermal/ chemical
Engine Company Handbook
The polyester hose jacket can melt in the range of ______.
500 F
Engine Company Handbook
Have the Sacramento Fire Hose Shop service-test hose if there is suspicion of a ________ exposure.
chemical
Engine Company Handbook
After such chemical exposures, hose must be thoroughly washed as soon as possible with _______, _______ water.
warm, soapy
Engine Company Handbook
The two primary types of hose couplings used by the Sacramento Fire are ________ and _________.
threaded / Storz
Engine Company Handbook
National Pipe Straight Hose (NPSH), also known as “pipe thread”, is used on __________ hose.
1” forestry
Engine Company Handbook
To ensure each section of hose is eventually rotated throughout the entire hose bed, the _________ method will be followed.
“first-to-last”
Engine Company Handbook
Remove _______ and ______ from the hose before placing it back into hose beds as this is a leading cause to the breakdown of the fibers in the jacket.
dirt / grit
Engine Company Handbook
When hose is sent in for repair, place an ______ next to its inventory number in the “Hose Rack” box.
“x”
Engine Company Handbook
Company officers are responsible for ensuring that newly received hose undergoes the _______ ______ process.
service test
Engine Company Handbook
All fire hose will undergo service testing on an _______ basis and after any ________ are made.
annual / repairs
Engine Company Handbook
Maximum length of hose to be tested per engine outlet is ______ feet.
300
Engine Company Handbook
Secure hose lines with rope and keep personnel at least _____ feet away from the testing area.
25
Engine Company Handbook
The 1 ¾” nozzle is a _______ ______ flow nozzle with an effective reach of ______ feet.
constant gallonage / 110
Engine Company Handbook
Fittings are identified in order by: _______; ________; _______.
size / direction of flow / fitting name
Engine Company Handbook
Size of the fitting listed as _______ side first, _______ side last.
female / male
Engine Company Handbook
An _______ is defined as any device through which water passes.
appliance
Engine Company Handbook
The adjustable pressure relief dump valve has a range from ___ to ___ psi and can unload up to ______ gallons.
50 / 300 / 1,000
Engine Company Handbook
The dump valve should be set to ______ psi on the intake located on the engineer’s panel and _____ psi on the officer’s side panel.
75-90 / 150
Engine Company Handbook
The LDH manifold has a pressure relief dump valve which ranges from ___ to ___ psi.
75 / 250
Engine Company Handbook
There are three basic types of hydrant wrenches that can be found on any Sacramento Fire engine company: ________, ________, and ________.
adjustable hydrant/spanner wrench / Corey Hydrant wrench / five-hole hydrant wrench
Engine Company Handbook
The hose roller is located on all _______ companies.
truck
Engine Company Handbook
FireAde has a working foam concentrate ranging from ___ percent to ____ percent.
0.1 / 3
Engine Company Handbook
How many gallons of foam concentrate are needed to make a 3 percent mixture for one booster water tank worth of water?
15
Engine Company Handbook
What is the rating for the Dry Chemical extinguisher?
2A: 10B: C
Engine Company Handbook
The use of an aerator can increase the foam blanket by up to ____ percent.
45
Engine Company Handbook
What are the two simple ideals of the Sacramento Fire Department?
The fire goes as the first line goes, If you put the fire out, everything gets better
Engine Company Handbook
The company officer’s responsibilities at a structure fire can be broken into what 3 basic phases?
Responding to, on arrival, suppression
Engine Company Handbook
The officer has several options for securing a water supply, name the 6?
1) tank water 2) lay-in wet 3) lay-in dry 4)lay-out 5) split lay 6) hand-jack
Engine Company Handbook
What are the 3 operational modes of the incident for a company?
Investigation, fire attack, command
Engine Company Handbook
Second and subsequent arriving companies base their operations on the __?
Initial actions taken by the first company
Engine Company Handbook
The _____ ______ is the accepted department standard for providing updates to incoming companies or the established incident commander.
C.A.N. Report
Engine Company Handbook
The first arriving officer, and/or back-up firefighter must control ___ _____ when possible.
The door
Engine Company Handbook
What 3 basic responsibilities does the engineer have during fire operations?
Delivering the crew and apparatus safely to the scene; pumping operations; securing a water supply
Engine Company Handbook
Third and later-arriving engines should consider taking a position where to provide additional hose lines if necessary?
In the alley behind the structure
Engine Company Handbook
If the structure is set back greater than ____, consider using the 200’ tank line.
100 feet
Engine Company Handbook
The ____ tankline should NOT be the first line stretched as it would require it to be backed-up with 3” and Sac Pack.
300’
Engine Company Handbook
For fires in public hallway apartment buildings and complexes (garden style), the _____ and _______ may be the most efficient option.
3” supply line, Sacramento Pack