Safety System Interlocks Flashcards
What are the ADS Logic Initiation signals?
Level 3(130 inches) and Level 1(16.5 inches) and RHR Pump discharge pressure of 125 psig or LPCS Pump discharge pressure of 145 psig and 105 seconds
What type of logic does ADS utilize?
1) 2 out of 2 taken once 2) Time delay and Instantaneous signals both required
What are the RRCS Alternate Rod Insertion initiation signals?
1) Level 2(130 inches) 2) 1083 psig 3) Manual Arm and Depress 4) Test
What is the RRCS Feedwater Runback initiation signal?
1083 psig and APRMS not downscale within 25 seconds
What is the RRCS Reactor Recirc Pump Downshift initiation signal?
1083 psig
What is the RRCS Reactor Recirc Pump Trip initiation signal?
1) Level 2( 130 inches) 2) 1083 psig if APRMs are not downscale within 25 seconds
What are the RPS Bus EPA Breaker trip signals?
1) 132 VAC 2) 108 VAC 3) 57 Hertz
What is the Low Pressure Coolant Injection initiation signal?
1) Level 1( 16.5 inches) 2) Drywell Pressure 1.68 psig
What type of logic does LPCI utilize?
Series/Parallel Logic
What is the Containment Spray Logic initiation signal?
LPCI initiation for 10 minutes( 10 minutes 35 seconds for B) and Drywell pressure 1.68 psig and Containment pressure 7.72 psig
What are the RHR pump trip signals?
1) Under-Voltage 2) Over-Current 3) No Suction Path( A/B Only)
What is the maximum injection pressure for the RHR pumps?
280 psig
What conditions cause the RHR Pump Minimum Flow Valve to automatically open?
RHR Pump breaker closed with less than 1650 gpm for 8 seconds
What condition causes the RHR Pump Minimum Flow Valve to automatically close?
Greater than 1650 gpm
What are the RHR Shutdown Cooling Isolation signals?
1) Level 3(178 inches) 2) RHR Room high temperature( 157 F) 3) Reactor Pressure 135 psig
What valves are closed by the RHR Shutdown Cooling Isolation signal?
1) E12-F008 RHR SDC Outboard Isolation 2) E12-F009 RHR SDC Inboard Isolation 3) E12-F023 RHR A Head Spray Isolation 4) E12-F037A/B RHR SDC Upper Pool Isolations 5) E12-F053A/B RHR SDC Feedwater Isolations
What are the LPCS Initiation signals?
1) Level 1(16.5 inches) 2) High Drywell Pressure 1.68 psig
What type of logic does LPCS utilize?
Series/Parallel Logic