Replace An Oxygen Valve Or Fitting Flashcards

1
Q

What kind of lubricant can be used for installing fittings in an oxygen system component?

A

Teflon tape or a special water-based lubricant

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is used to check for leaks after replacing a fitting in an oxygen system?

A

A special leak-detector liquid that is form of non-oily soap

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What cleaning solutions can be used to clean parts used in an oxygen system?

A

Anhydrous ethyl alcohol, isopropyl alcohol, or freon

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What may be used to dry components in an oxygen system after they have been cleaned?

A

Water-pumped dry nitrogen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What may be used to purge the lines in an oxygen system after it has been opened for servicing?

A

Water-pumped nitrogen

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

What must be done before any maintenance can be done on an oxygen system?

A

The oxygen supply must be turned off at the bottle valve

How well did you know this?
1
Not at all
2
3
4
5
Perfectly