Leak Test Gaseous Oxygen System 2 Flashcards

1
Q

What kind of gaseous oxygen must be used to service an aircraft oxygen system?

A

Only aviators breathing oxygen.

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

What is a continuous-flow oxygen system?

A

An oxygen system that continuously flows a metered amount of oxygen into the mask

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

What is a pressure-demand oxygen system?

A

An oxygen system that flows oxygen to the mask only when the wearer of the mask inhales

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

What identification must be stamped on an oxygen bottle carried in an aircraft?

A

The identification DOT 3AA or DOT 3HT, the date of manufacture, and the date of all hydrostatic tests

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

To what pressure, and how often should DOT 3HT oxygen cylinders be hydrostatically tested, and when should they be retired from service?

A

They should be tested to 3 083 psi every three years and retired from service after 15 years or 4,380 pressurizations, whichever occurs first

How well did you know this?
1
Not at all
2
3
4
5
Perfectly