Reactor Protection System Flashcards
1
Q
State two functions of the Reactor Protection System.
A
- To protect the reactor core
Not to exceed Technical Specifications
Protect the health and safety of the public & staff. - To protect plant equipment
2
Q
Identify five Reactor Protection System Trips.
A
- High Power Level (Variable)
- High Rate of Change of Power
- Low Reactor Coolant Flow
- Low Steam Generator Water Level (either A or B)
- Low Steam Generator Pressure (either A or B)
- High Pzr Pressure
- *Thermal Margin/Low Pressure (TM/LP)
*Asymmetrical SG Transient – via TM/LP - Loss of Load
- High Containment Pressure
- Local Power Density (LPD)
- Loss of RCP Component Cooling Water (Unit 2)
- MANUAL