Quiz #23 Flashcards
According to Book 1 Basic Inspection Guide, Provide and maintain appropriate numbers on a contrasting background and visible from the street to indicate the correct address of the building. Minimum size is _____ inches high by ______ inches wide
4 inches, 2 inches
According to Book 1 Basic Inspection Guide, All Fire Department sprinkler and standpipe inlet connections shall be provided with approved signs indicating the type of system and the area served. Signs shall be securely attached to the building adjacent to the inlet connections. Signs shall be not less than ____ inches in width and _____ inches in height.
8” wide & 4” high
According to Book 1 Basic Inspection Guide, Apartments, Hotels, Condominiums and Apartment/Hotels, In the event an apartment house has ____ or more dwelling units or a hotel has ____ or more guest rooms, either the owner or a responsible resident having charge thereof shall reside on the premises
Apartment 16, Hotel 20
According to Book 1 Basic Inspection Guide, Apartments, Hotels, Condominiums and Apartment/Hotels - In every building other than single family dwellings, there shall be maintained at all times, one unobstructed aisle which leads to each required exit. Each required aisle shall have a width equal to the minimum required in other sections of this article or when not specified, the minimum width shall be ______.
44”
According to Book 1 Basic Inspection Guide, Apartments, Hotels, Condominiums and Apartment/Hotels - By a window openable from the interior without the use of a key, tool, or special knowledge or effort, as determined by the Chief. Such window shall have minimum dimension of ____ inches when open. The sill shall be not more than ____ inches above the floor and landing.
29”, 30” sill
According to Book 1 Basic Inspection Guide, Apartments, Hotels, Condominiums and Apartment/Hotels - Every person owning or managing a building three or more stories in height shall provide and maintain an approved stairway identification sign at each floor level landing in every stair shaft. The sign shall indicate the __________________________________
floor level, the lower and upper terminations of the stairway, whether or not there is roof access, and the identification of the stairway
According to Book 1 Basic Inspection Guide, Apartments, Hotels, Condominiums and Apartment/Hotels, the following garden -type residential occupancies which have exits from each dwelling unit or guest room opening directly to an open exit corridor, courtyard, driveway, alley, or street shall not be required to have portable fire extinguishers:
(Garden-type) Apartment houses containing 15 or less apartments and not over two stories in height.
(Garden-type) Hotels containing 19 or less guest rooms and not over two stories in height
According to Book 1 Basic Inspection Guide, Light Industrial Occupancy - Class I liquids shall not be stored in basements, B) Class Il and III liquids may be stored in a basement only with a special permit issued by the Chief. A special permit allowing basement storage of Class II and III liquids is subject to the following conditions:
Class II liquids - 60 gal
Class IIIA liquids - 120 gal
Class IIIB liquids - 180 gal
According to Book 1 Basic Inspection Guide, Place of Assemblage - Restaurant, Night Clubs, Dance Halls - EXIT DOORS, Width and height: Every required exit doorway shall be of a size so as to permit the installation of a door not 1 less than three feet in width and not less than six feet eight inches in height. When installed, exit doors shall be capable of opening so that the clear width of the exit not less than ______ inches.
32 inches
According to Book 1 Basic Inspection Guide, NIGHT INSPECTIONS - Place of Assemblage, The storing or keeping of any combustible merchandise, materials, or equipment in any sub -floor area, attic, boiler room, mechanical room, heating equipment room, water heater closet or electrical panel room in a manner which would create or constitute a fire hazard is _____________
prohibited
According to Book 1 Basic Inspection Guide, Auto Fueling Stations - This switch shall be easily and readily accessible from the dispensing apparatus and shall be posted with a permanent sign with letters one -inch high stating “GAS PUMP SHUT -OFF. “ This switch must not be closer than ______ feet nor farther than ______ feet from any dispenser
no closer than 15’ & no farther than 100’
According to Book 1 Basic Inspection Guide, Auto Fueling Stations - Within ____ feet of every dispenser there shall be located at least one portable fire extinguisher having a minimum rating of 2A, 20B:C
75’
According to Book 1 Basic Inspection Guide, Auto Fueling Stations - No open flame producing device used on any Public Garage or Auto Fueling Station premises shall be located or brought within ____ feet of any dispenser, except heaters installed as required by Section 57.100.32
25’
According to Volume 6, 11/0-00.00 FIRE PREVENTION, Pre-Fire Planning and Fire Prevention, General occupancies with 1 required exit interval is _________________ and general occupancies with 2 or more required exits interval is __________________
once every 3 years,
once each year
According to Volume 6, 11/0-00.00 FIRE PREVENTION, 11/1 FIRE PREVENTION/GENERAL, Officers in the Bureau of Emergency Services or the Fire Prevention Bureau may initiate transfers of inspection responsibility. This transfer may be completed upon agreement by the responsible officers. Also initiate an F-____, if, during a pre-fire planning inspection, it is discovered that the occupancy should be a fire station inspection responsibility
F-44