According to TB# 169 Hot Stick, the Hot Stick was specifically designed with first responders in mind to provide warning of exposed high voltage ______________ from a safe distance
alternating current
According to TB# 169 Hot Stick, The Hot Stick consists of a high sensitivity AC amplifier for the frequency range of ____ to _____ Hz.
20 to 100 Hz
According to TB# 169 Hot Stick, the __________ setting is utilized to pinpoint a source.
front focused
TB #169 states that the Hot Stick has been tested to operate continuously for 300 hours by the manufacturer. It is recommended to change the four (4) AA batteries at least ___________ or when discharged
annually
According to TB# 169 Hot Stick, the Hot Stick requires no warm up and is ready for use in ___ seconds after turning it on
5 seconds
According to TB 151 - Progressive Hose Lay and the Smokey Pack Lightweight Hose System, the disadvantage of the Progressive Hose Lay is
the higher friction loss due to the increased number of fittings.
According to TB 151 - Progressive Hose Lay and the Smokey Pack Lightweight Hose System, a Company given the task of establishing a progressive hose lay is expected to, at a minimum, be able to put in ________.
3 drops
TB 151 - Progressive Hose Lay and the Smokey Pack Lightweight Hose System states that each drop of a Progressive Hose Lay shall consist of all the following…
100’ 1½” Single Jacket Hose (Minimum size for the trunk line)
100’ 1” Single Jacket Hose (Attack and lateral line)
1½” Gated Wye with one 1½” to 1” Reducer
1” Nozzle (10/40 Dual Gallonage)
(2) Rubber Bands or ladder straps to secure gates.
According to TB 151 - Progressive Hose Lay and the Smokey Pack Lightweight Hose System, the first step to assemble a Smokey Pack is to lie out 100’ section of 1” hose and fold in half, with the male on top, placed ____” behind the female coupling.
24”
TB 151 - Progressive Hose Lay and the Smokey Pack Lightweight Hose System states that the service test pressure for this hose is ______ psi.
300 psi
TB 150 - Drager X-am 5000 Combustible Gas Indicator states that it is equipped with 4 gas-specific sensors and a fifth catalytic sensor for explosive vapors. The four gas specific sensors are all the following…
Oxygen
Carbon Monoxide
Hydrogen Sulfide
Hydrogen Cyanide
According to TB 150 - Drager X-am 5000 Combustible Gas Indicator, IMMEDIATELY LEAVE ANY AREA WITH OXYGEN READING GREATER THAN ______%, THERE IS DANGER OF EXPLOSION!
23.5%
According to TB 150 - Drager X-am 5000 Combustible Gas Indicator, the combustible gas sensor may display incorrect readings in oxygen-poor atmospheres with less than ___% oxygen
10%
TB 150 - Drager X-am 5000 Combustible Gas Indicator states that a Bump Test is required
anytime the meter registers readings after being used in suspected IDLH atmospheres.
According to TB 150 - Drager X-am 5000 Combustible Gas Indicator the level a worker can be exposed to a chemical substance for an 8 hr./day, 40-hr/week-work schedule without adverse health effects is called the…
time weighted average
According to TB 103 - Foam Dispensing Equipment, Class “B” foam…
forms a blanket over flammable liquids, sealing flammable vapors under the foam.
According to TB 103 - Foam Dispensing Equipment, when using the hydro-foam nozzle expect to use ____ gallons of concentrate per minute of operation while water is flowing.
20 gallons
TB 103 - Foam Dispensing Equipment states that when operating the 1 1/2” in-line foam eductor, pump ______ psi to the eductor inlet
200 psi
According to Volume 3, 6/5, hose used in the field comes in 50-foot sections, but may be shortened during repairs. No section, however, will be issued for fire fighting use if it has been shortened to less than ___ feet. Lengths of hose less than ___ feet may be used as bypasses or suctions.
40’, 40’
Volume 3, 6/5, states that a(n) __________ is a gate valve installed on a hydrant outlet for use by contractors, etc. This valve permits repeated opening and closing of the hydrant without using the regular valve
Eddy valve