queens 5 Flashcards
Question 1:
Choose the incorrect radio “10” code
A: 10-21 for a Brush Fire
B: 10-22 for an Outside Rubbish Fire
C: 10-24 for an Abandoned/Derelict Fire (ADV)
D: 10-25-3 for smoke seeping from a manhole
c Explanation:
10-23 is for an Abandoned/Derelict Fire (ADV)
10-24 is for an Auto Fire (A fire in a vehicle with plates or in any vehicle having a value greater than that of salvage
Communications ch 8 page 8
Question 2:
Two officers reviewing under river rail operations were incorrect in which statement?
A: Engine Company Chauffeurs must be aware of head pressure when calculating the appropriate pressure to supply to siamese connections. Units may be operating 50 to 100 feet below grade.
B: The discovery of a water-flow in a tube is cause for concern. An explosion could rupture the standpipe, making it necessary to shut section valves to isolate leaks.
C: Standpipe numbers are sequential and can be used to provide an approximate location of an incident.
D: All subway trains are powered by an alternating current (AC) catenary wire. Power removal and stopping of train traffic shall be requested and confirmed through the borough dispatcher
d Explanation:
D) All subway trains are powered by a direct current (DC) third rail. Power removal and stopping of train traffic shall be requested and confirmed through the borough dispatcher.
Under River Rail 2.7.3, 2.8
Question 3:
You just discovered that the apparatus radio is defective. After notifying the radio mechanic via the dispatcher, you also notify the Battalion and Division that you will be using a citywide radio capable of direct communications with all Borough dispatchers until the apparatus radio is repaired. The citywide radio shall be supplied by who?
A: Battalion
B: Division
C: Borough Command
D: Radio Shops
b Explanation:
Comm ch 8 page 30
Question 4:
10 minute escape cylinders used by Special Operations Command (SOC) units for confined space, need to be hydrostatic tested every __ years.
A: 3
B: 5
C: 15
D: 10
d Explanation:
TB SCBA 3.2.4 A
Question 5:
In the event of a radiological incident, members might be ordered to take Potassium Iodide (KI) tablets to protect the thyroid gland from radioactive iodine. Who is the only person that can give this order?
A: Chief of Department
B: Battalion Chief on scene
C: Division Chief on scene
D: Borough Commander
a Explanation:
ERP add 4C sec 5.4
Look at 5.2……Engines, Ladders, Squads, Rescues, Battalions, Divisions, Borough Commanders, and Command Chiefs shall all carry KI tablets in the glovebox of their apparatus/vehicle. Additional caches of KI tablets will be stored at Division offices. If needed, units and/or members must respond to the NEAREST Division office, or as directed, to obtain KI tablets
Question 6:
The role of the salvage truck at an operation is an important one. Which choice below reflects an incorrect use of “salvage covers”?
A: 9x12 ft. sheets are used to cover furniture, machinery, rugs or other large pieces or areas.
B:They cover roof openings.
C: They form catch basins for water on floors below.
D: 9x12 ft. sheets can be used to cover window openings.
d Explanation:
Smaller sheets, 4 1⁄2 x 6 ft. can be used to cover window openings.
TB Salvage 5.1
Question 7:
At a “Surf Rescue” operation, there are several operational procedures that should be considered. Choose the incorrect one
A: Assure the Borough Dispatcher is initially notified when there is a confirmed victim.
B: All members entering the water are to wear a PDF and be tethered.
C: If the surf board is to be used, it does not have to be tethered, since mobility is key in rescuing a victim
D: When the NYPD helicopter is operating in close proximity, the IC should be aware that the area beneath the helicopter can be dangerous due to rotor downwash.
c Explanation:
A. 4.4
B. 4.6
C. If the surfboard is used, it must also be tethered to the shore and attached to the rescuers ankle with approved leash. 4.6
D. 4.9
EP Water Rescue 4 surf rescue
Question 8:
At a fire in a high-rise office building, utilizing “natural vertical ventilation” to increase the stack effect and assist in the removal of smoke via the stairway can be accomplished how?
A: Opening the doors at the top and bottom of the stairway once the fire is extinguished.
B: Opening the doors at the top of the stairway only, once the fire is extinguished.
C: Utilizing positive pressure fans once the fire is extinguished.
D: Utilizing building stairway positive-pressure systems once the fire is extinguished.
a Explanation:
High Rise Office Buildings 6.3.8 D
Question 9:
At a fire in a LRFPMD, FFs must be on their game especially when it comes to the LSR evolution. Choose the incorrect answer for the LSR evolution
A: Operate from the roof if practical
B :If it is determined that a LSR is not practical from the roof by the first Roof FF, then the first Roof FF shall direct the second Roof FF to the floor above the rescue if the second Roof FF has not already reached the roof
C: In buildings with two open interior stairs, the 2nd Roof FF may descend the evacuation stairway to the apartment directly above the fire apartment
D: In buildings with an open interior stairway, the IC may direct members or another unit to bring an available LSR to the apartment directly above the apartment
c Explanation:
MDs (page 90) Two ENCLOSED STAIRS
Question 10:
Two members discussing regulations pertaining to housewatch duty were incorrect in which comment?
A: Firefighters Sixth Grade with less than 6 months of service may perform housewatch only between the hours of 0900-2400 provided they are monitored by the officer on duty or by an experienced member.
B: Tours of housewatch duty shall begin at 0900 hours each day, and be divided into eight 3-hour periods. Each tour shall be performed by one member.
C: Company Commanders shall arrange and maintain schedules of assignments to housewatch duty. Assignments shall be equalized and a copy of such schedules posted at the housewatch desk.
D: In a company quarters housing more than one unit, the events of all units shall be recorded in one Company Journal. Housewatch duty shall be performed by members of all such units, alternating monthly in performance of such duty.
a Explanation:
A) …with less than ninety days service…
Regs 20.1.1-20.1.4
Question 11:
Who shall ensure the sprinkler system is supplied for a lower floor fire in Cast-Iron/Mill Loft building?
A: 1st Engine Company
B: 2nd Engine Company
C: 3rd Engine Company
D: 4th Engine Company
Lofts 6.2.2.C.2
C
Question 12:
At a brownstone building that is fully involved, the first arriving engine company should drop two hoselines in front of the fire building and position the apparatus for the possible use of the multiversal nozzle or to supply a TL. In this scenario the most correct position for the second hoseline can be found in which choice?
A: Advanced into the fire building as the initial hoseline.
B: Advanced into the fire building as a back-up hoseline.
C: If fire is reported in an exposure, stretched to that exposure.
D: If there is no fire in the exposures, stretch through an exposure to the rear yard of the fire building.
B
Bwst 3.4
Question 13:
The placement of an Aerial ladder apparatus (tractor-trailer and rear mount) is dependent on four conditions. Choose the incorrect condition
A: Whether an immediate rescue is apparent
B: Where no immediate rescue effort is required, the height of the building will dictate the placement
C: Smoke, heat or fire causing an exposure that would endanger a victim, a member or the ladder
D: Area or street condition that might hamper optimum positioning
Explanation: Where no immediate rescue effort is required, the size of the frontage of the building to be covered in case of future need Ladders 2 (Aerial Ladders) 2.1
Question 14:
When operations are within the capability of a single unit at a manhole fire, the Officer in Command may leave one unit (preferably an Engine Company) to await the arrival of the emergency crew. If the expected time of arrival is more than 30 minutes, the Officer in Charge, based on evaluation of existing conditions, may order one of the following. Which option is listed incorrectly?
A: The unit remaining on the scene may respond to assigned alarms received via department radio; one member shall be left at the scene.
B:One member shall be left at the scene and the unit shall return to quarters. The Battalion Chief shall provide relief for members.
C: When a member is left at the scene, the company officer shall at frequent intervals contact the dispatcher for re-notification of the utility company.
D: The manhole shall be protected by traffic cones and tape, and all units placed in service.
B Explanation:
B) One member shall be left at the scene and the unit shall return to quarters. Company officers shall provide relief for members.
AUC 180 2.6
Question 15:
Select the most correct statement regarding PPV fan use at a HRFPMD fire
A: The evacuation stairwell is the first consideration for pressurization
B: Pressurize the attack stair for smoke and CO control
C: The priority order for the use of PPV will be pressurizing the attack stair, pressurizing the evacuation stair for smoke and CO control, and ventilating the public hallways for smoke and CO control
D: PPV fan use will not be used until the fire is placed under control
Explanation:
MDs (6.19.2)
A. The attack stair is the first consideration for pressurization
B. Pressurize the evacuation stair for smoke and CO control
D. Can be used during the initial attack
Question 16:
All units listed below carry search cameras that can extend through holes bored in floors and roofs to quickly identify and survey voids during collapse operations except in which choice?
A: Rescues
B: Squads
C: Collapse Rescue Units
D: SOC Support Ladder Companies
D Explanation:
Collapse Figure 7