PP 001/002/003 Flashcards

1
Q

The main features of the Mercedes Series 3 pumping appliance

A

• Godiva 3010 Multi-pressure pump (capable of 3000 litres per minute at 10 bar pressure with a 3 metre lift)
• Capable of simultaneous high and low pressure operation
• Onboard water tank 1365L
• Onboard foam tank 80L
• Tilt and slide shelving
• Beam ladder gantry for 9m ladder

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

PTO stands for

A

Power Take Off

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Types of pumping appliances:

A

Pump (crew of 4)

Pump ladder (crew of 4)

Dual-purpose pump ladder at one-appliance stations (crew of 5)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

If defects are observed, what should you do?

A

Report to the driver and the appliance commander ASAP

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

What is the purpose of appliance inventories?

A

• Make sure all equipment is present
• To check the condition and readiness of the equipment
• To check the equipment is stowed correctly on the appliance

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Who must ensure all equipment has been stowed correctly with lockers secured?

A

The driver

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

List the 7 pump gauges:

A

• Hydrant to tank auto-fill valve
• Tank to pump valve
• Low pressure delivery valve
• High/low pressure lever
• Hose reel isolation valve
• Emergency stop switch
• ePump control (ePC)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

The 3 parts of an appliance inventory check

A

• Equipment checks
• Condition checks
• Inventory check

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

Sudden increase in the low pressure gauge reading could indicate

A

• Branches being shut down
• Kinks in the delivery hose
• Vehicles or debris in the delivery hose

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Sudden decrease in low pressure gauge reading could indicate

A

• Branches being opened
• Burst delivery hose
• The appliance tank is empty

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

There are two types of pumps on the appliance

A

• the centrifugal pump
• positive displacement pump

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Bar required for the hose reel

A

6 bar required for 1 length (4 lengths on each side) (4x6=24bar+6 at branch=30bar)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Two stage pump

A

High pressure (hose reel) - impeller moves small volumes of water at high pressure (x5 greater pressure)

Low pressure (main jet/s) - impeller moves large volumes of water at low pressure

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Portable pump:
weight
engine
output
max output
duration
max pressure

A

4 stroke HP petrol
84 kg
800lpm at 5 bar
1000lpm at 4 bar
1.5hrs at 5 bar
8 bar

How well did you know this?
1
Not at all
2
3
4
5
Perfectly