The main water service should be plumb/level within _________ of an inch? And be ______________ inches AFF.
- 1/4”
- 24”
The main water service should be ____________ inches away from the stem wall. And have the irrigation T installed ________ the shut-off valve.
- 6” - 8”
- Below
Secondary hose bibs should be plumb/level, and be _______ inches AFF, and extend __________ inches past the stucco.
- 24”
- 3” - 4”
Should any hose bib leak from any location?
No.
Cleanout caps are to be ________ inches above grade measured from the _________ of the nut on the cap.
- 3”
- Top
Cleanouts in the garage floor or concrete walks are trimmed with _______ ________?
Brass covers
What’s the tolerance for plumb/level on the water heater?
No tolerance
Where do you position the drain valve on the hot water heater?
Where it is easily accessible
What is required at the hot water heater when the home has a deck mount tub?
A mixer valve
Where should the warranty book for the hot water heater be located?
On the water heater or in the kitchen drawer
All plumbing and gas lines at the hot water heater are to have an ___________ plate. And all plates are to __________.
- Escutcheon
- Match
All water heater B-vent connections are to have _______ screws.
3
The hot water heater B-vent should have a __________ __________ installed tight to the lid.
Storm collar
The T and P drain line at the exterior of the home is to be plumb/level, and extend _________ inches past the stucco, with a _______ degree elbow.
- 3”- 4”
- 90˚
Should any fixtures of any kind have any damage/defects?
No