Tooled joints in concrete are to be straight within a ______ of an inch in _______ feet?

A

1/4”
8’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Tooled joints in post-tension areas are to be cut a minimum depth of _______ of an inch?

A

3/4”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

A ________ _________ is to be installed at the front edge of all garage floors.

A

Beveled edge

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

No chatter marks or tool marks in flatwork visible from a minimum of _________ feet.

A

5’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

No tolerance for ________, ___________, or ________ ________ at exposed flatwork.

A

Chips
Gouges
Saw Cuts

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Cracks at POST-TENSION slab areas:
- Cracks up to __________ of an inch with no vertical displacement do not patch.
- Compound cracks up to ________ of an inch with no vertical displacement is acceptable, do not patch.
- Compound cracks exceeding ______ of an inch with any vertical displacement is reviewed.

A

3/32”
1/16”
1/16”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

Cracks at NON post-tension slab areas:
- Cracks up to _______ of an inch with no vertical displacement are patched.
- Cracking exceeding ______ of an inch, or vertical displacement exceeding _______ of an inch requires R/R.
- ____________ cracking requires R/R.

A

3/32”
3/32”
1/8”
Compound

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

There are to be no _______, ________, _______, ________ or chips that exceed ______ inch in diameter in the stem wall.

A

Nails
String
Wire
Honeycomb
1”

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

The bollard post is to be plumb within ________ inch, filled with ___________ and capped smooth.

A

1/4”
Concrete

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Post-tension stamp is to be within _______ inches from either side of the center control joint and a maximum of ________ feet from the front edge of the garage floor.

A

12”
2’

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

What size landscape conduit under the driveway are acceptable?

A

One - 3” PVC pipe or two - 2” PVC pipes

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Where should the landscape conduit under the driveway be located and how far past the edges of the driveway should they extend?

A

Located 4 - 5 feet back from the citywalk
Extend past the driveway 6” on both sides

How well did you know this?
1
Not at all
2
3
4
5
Perfectly