Electrical Flashcards
All electrical trim plates are to have the flat screw heads positioned ______________.
Straight up and down
All GFCI receptacles are to be clearly _________.
Labeled
All electrical trim plates are to be ___________ with the drywall, and installed __________.
Flush
Square
__________ defective or damaged electrical fixtures.
Replace
How are half-hot receptacles to be installed?
Upside down with the switched outlet located at the top
Floor outlets are trimmed with a ______ ________.
Brass housing
___________ __________ are installed on all outlets in combustible areas.
Sock-o rings
Disposal switches are to be mounted inside the cabinet and placed ______ inch from the face frame and _________ inches AFF.
- 1”
- 24”
Bulbs in recessed cans are to be ___________.
Centered in the fixture
A/C disconnect boxes are installed behind A/C condenser units. True or false?
False
They are positioned to the sides of the condenser units
The flexible conduit at A/C disconnects are to be secured within ________ inches of the box.
12”
Should the air handler be hard wired with a separate switch or have a pigtail?
Yes, hard wired. No pigtail.
Do you need a weatherproof cover on an exterior GFCI?
Yes. All exterior GFCIs require waterproof covers.
Garage outlets that are NOT on the standard GFCI circuit are to be ______________.
Identified/labeled
What are not required to be on arc fault breakers?
Appliances
GFCIs