CABIN PRESS
MODE SEL pb
AUTO-normal lights out mode. Allows automatic cabin pressurization and landing elevation
MAN-flight crew can manually adjust cabin altitude with the MAN V/S CTL
FAULT-comes on only when both automatic systems have failed.
Pushing this pb to MAN for at least 10secs then back to AUTO will select the other system
AC ESS FEED pb
Normal-Lights out AC BUS 1 is powering the AC ESS BUS
ALTN- when pushed manually selects AC BUS 2 to power the AC ESS BUS
FAULT-AC ESS BUS is unpowered
BAT 1 and 2
ON- lights out
OFF-in white and battery line contact is open. Hot bus remains powered
FAULT-amber when charging current is outside limits
IDG 1 or 2 pb
Normally lights out
FAULT-amber if IDG oil overheat or IDG oil pressure low
GEN 1 or 2
APU GEN
ON lights out
OFF - generator field is de-energized and fault circuit resets
FAULT- associated generator trips
BUS TIE pb
Normal lights out
OFF- both tie contractors open
GALLEY pb
Auto lights out. Main galley and ife are automatically shed inflight and on the ground with only one generator. Anytime APU or EXT power are hooked up they’re not shed. Secondary galley remains on in all these senerio’s
OFF-Both galleys and ife shed
FAULT-when load on any generator is more than 100% output
COMMERCIAL pb
On lights out (all powered)
OFF- commercial loads are off
EMER ELEC PWR
MAN ON pb
Auto lights out allows automatic deployment of RAT when both ac buses are not powered and above 100kts
Pressed manually extends RAT
EMER GEN TEST pb
GEN 1 LINE pb
Normal lights out
OFF- opens contactor
SMOKE- illuminated when smoke is detected in avionics ventilation duct
EMER ELEC PWR
RAT & EMER GEN LIGHT
FAULT in red if emergency generator is not supplying power whe AC BUSS 1&2 are not powered
APU panel
MASTER SW
START
MASTER SW pb- When pressed blue ON light, power-up test, intake flap opens, APU fuel pump operates if no tank pump is operating, APU page.
Pressed while ON lights on both APU switches go out and starts shutdown sequence
FAULT-amber comes on when an automatic shutdown occurs
START pb-pressed a blue ON light and start sequence initiated and green AVAIL light when on speed
ENG 1&2 BLEED pbs
On is lights out
FAULT-amber comes on overheat over press or bleed valve not closed during engine start or APU bleed on
OFF-bleed valve and HP valve close
APU BLEED pb
ON illuminates when pushed and valve opens when on speed and no leak
Off- the APU valve closes (no OFF light)
FAULT-amber when detects APU bleed leak