OSHA Flashcards

1
Q

The Prime Contractor Is Responsible

A

For Safety - 0.16

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
2
Q

Emergency Actions Plans For Companies With Fewer Than

Ten Persons

A

Need Not Be In Writing - .35(e)(3)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
3
Q

Common Drinking Cups Must Not Be Used

A

Not Be Used - .51(A)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
4
Q

See Video For List Of Acceptable Types Of Chipping Goggles

A

102

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
5
Q

Does Employer Provide Protection?

A

Yes - .102(a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
6
Q

Safety belt lanyard shall be ______ Nylon and withstand a Fall of No More Than ____ feet, breaking point ______ Lb.

A

1/2”, 6, 5400 - .104(d)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
7
Q

List Class B fire extingusher types -

A

Foam, Carbon Dioxide, Chemical - .150, TABLE F-1

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
8
Q

A Fire Extinguisher not rated less than______Per _____ Sf of building area.

A

2A, 3000 - .150(c)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
9
Q

No more than ______ Gallons Of Flammable Liquids May Be Stored in a room Outside Of
Approved Storage Cabinets

A

25 - .152 b

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
10
Q

Access Way ______Wide To Within ______ Feet Of Storage Containers

A

12’, 200, - .152 c (2)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
11
Q

Every container / vaporizor safety valve shall discharge not less than _____horizontally away from any opening to the building

A

5 feet - .153(d)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
12
Q

Distance That Flammable Materials May Be Stored Away

From Liquified Petroleum Gas

A

0, 10,20,25 - .153(k) TABLE F-3

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
13
Q

Flammable Materials Distance From Heating Device

A

.154(b)(2) TABLE F-4

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
14
Q

Heating Devices At Least _______Away From Tarpaulins

A

Ten feet - .154(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
15
Q

Materials stored in a building shall be At Least ______From Exterior Wall

A

Ten Feet - .250(b)(1)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
16
Q

Bagged materials shall _______ layers and cross key at least every ____ Bags High

A

step back, Ten - .250(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
17
Q

Brick Stacks shall not be more than____ high, Loose brick tapered ______for every foot over 4 feet.

A

7’, 2 inches - .250(b)(6)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
18
Q

Masonry Block stacked over _____feet shall be taperd ______ per tier.

A

Six, 1/2 block .250(b)(7)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
19
Q

Lumber Stack Heights, not to exceed _______, no more than _____ if handled manually

A

20 feet, 16 feet - .250(b)(8)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
20
Q

Wire Rope Shall Not Be Used When More Than _____Of The Strands Have Been Damaged Within A Length Of ______.

A

10% , 8 Diameters - .251(c)(4)(iv)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
21
Q

Chute Required When Dropping Debris More Than ______Feet.

A

20 - .252(a)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
22
Q

When Debris Is Dropped Thru Holes In Floors, A _____ High Barricade _______Outside The Hole Must Be Installed Around The Drop Zone On The Lower Floor.

A

42”, 6” .252(b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
23
Q

Skill Saws Are Required To Have ___________ Guards

A

“Point Of Operation” - .300(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
24
Q

Compressed Air Used For Cleaning Purposes Shall Not Exceed ?

A

30 Psi - .302(b)(4)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
25
Q

Abrasion Wheel safety measures

A

Sufficient power, Safety guards, spindle end, nut and flange protection - 0.303

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
26
Q

Gas Storage Requirements…….Gas Welding and cutting - Know the section

A

.350(a) & (d)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
27
Q

Welders Working In Confined Spaces…. 3 Requirements

A

Ventilation, Respirator, Safety line - .353(b)

How well did you know this?
1
Not at all
2
3
4
5
Perfectly
28
Q

Scaffolds Must Support At Least ______ The Intended Weight

A

Four Times - .451(a)(1)

29
Q

Minimum With Of Scaffold Platforms Is

A

18” - .451(b)(2)

30
Q

Maximum Distance From Outrigger Scaffold Platform To

Face Of Building Is

A

3” - .451 (b)(3)(i)

31
Q

Maximum Distance From Scaffold To Face Of Building When Applying Stucco Is

A

18” - .451(b)(3)(ii)

32
Q

Each End Of A Scaffold Must Extend ____ Past The Scaffold Support

A

6” - .451(b)(4)

33
Q

Scaffold Anchor Spacing

A

20 feet, not more than 30 feet - .451(c)(1)

34
Q

Scaffolds Erected Under Supervision Of

A

A Competent Person - .451(f)(7)

35
Q

Scaffold Handrail Height Between ______ And _______Above Scaffold Platform

A

36”, 45” - .451(g)(4)(ii)

36
Q

Scaffold Wire Rope Shall Be ______ And Without ________ Between Anchors

A

Continuous, Splices - .452(r)(4)

37
Q

Guardrails Are Required When Working More Than ________ High

A

6’ Feet - .501(b)(2)

38
Q

Guardrails Are Required When Excavation Is Deeper Than _______ Feet

A

6 - .501(b)(7)

39
Q

Structurall systems to support _______ Pounds

A

200 - .502(b)(3)

40
Q

A Lanyard Should Be Connected At __________ Of The Wearers Back

A

The Center Point - .502(d)(17)

41
Q

Covers Must Support _______ The Intended Weight

A

Twice - .502(i)(2)

42
Q

Control linse must be located not less than _____feet nor more than _____feet from unprotected edge

A

6, 25 - .502(G)(1)(i)

43
Q

Rubber Tired Heavy Equipment Requires Fender if travelling more than_______ MPH

A

15 - .602(5)

44
Q

Clearing Equipment Rollover Canopy_____Thick, wire mesh nor than ____ inch

A

1/8”, 1/4” - .604(a)(2)(i)

45
Q

What is a Kickout?

A

Anaccidental release or failure of a cross brace - .650(b)

46
Q

In Excavations More That _____ Deep ladders are located _____ apart.

A

4 Feet, 50 feet - .651(c)(2)

47
Q

Air Quality Must Be Tested In Excavations

A

Prior To Beginning Work - .651 (g)(1)(i)

48
Q

Minimum Percent Oxygen Is _____, Maximum ______

A

19.5%, 23.5% - .651(g)(1)(iii)

49
Q

Materials Stored At Least ______ From The Edge Of An Excavation

A

2 feet - .651 (j)(2)

50
Q

Who Inspects Excavations On a Regular Basis?

A

Competent Person - .651(k)

51
Q

A Handrail Is Required For Walkways Over Trenches More Than ______ Deep

A

6 Feet - .651(i)

52
Q

Employees Must Be Protected From Cave-Ins When Excavation More Than

A

5’ Deep - .652(a)(1)(ii)

53
Q

Excavations May Be ______ Below Trench Box

A

Two Feet - .652(g)(2)

54
Q

Unconfined Compressive Strength, What are two filed tests?

A

Pocket Petrometer, Thumb Penetration - Appendix A to Subpart P

55
Q

Maximum Allowable Slopes….. Know this table

A

Appendix B to Subpart P, TABLE B-1

56
Q

How shall Formwork be designed?

A

To withstand verticle or lateral loads - .703(a)

57
Q

Masonry Wall Over High Shall Be Braced

A

8 Feet - .706(b)

58
Q

Persons ____________ Of Loads May Work Under Loads

A

Responsible For The Hooking - .753(d)(1)(ii)

59
Q

Structural Steel Assembly Of Multistory Building

A

Perminant floors installed as structure progresses.754(b)

60
Q

Solid Floors No More Than ______ Below Steel Erectors

A

30 feet - .754(b)(3)

61
Q

When Debris Is Dropped Thru Holes In Floors, A ____High Barricade______Outside The Hole Must Be Installed Around The Drop Zone On The Lower Floor.

A

42”, 6 Feet - 850(h)

62
Q

A Change In Elevation Of _______Requires A Ladder Or Stairs

A

19” - .1051A

63
Q

At Least______Handrail On Enclosed Stairs

A

One - .1052(c)(1)(i)

64
Q

When Accessing A Roof With A Ladder, The Ladder Must Extend _____Above The Roof

A

3 Feet - .1053(b)(1)

65
Q

Ladders Should Slope So That The Distance From The Base Of The Ladder To The Base Of The Building Is Equal To The Working Length Of The Ladder

A

1/4 - .1053(b)(5)(i)

66
Q

The Atmosphere In Confined Spaces Must Be Tested For __________ Prior To Persons Entering.

A

Oxygen, Flammable Gases, And Toxic Air Contaminants - .1203(e)(2)(iii)

67
Q

The Distance From A Crane Boom And A Power Line Rated Less Than 50Kv Must Be At Least?

A

10 Feet - .1408(h) Table A

68
Q

A Crane Must Be Inspected By ________ Prior To Each Shift

A

A Competent Person - .1412(d)(1)

69
Q

Employers must use assigned protection factors listed in table______ that meet or exceed requirements

A

Table 1 - 1910.134(d)(3)(i)(A)