OSHA Flashcards
The Prime Contractor Is Responsible
For Safety - 0.16
Emergency Actions Plans For Companies With Fewer Than
Ten Persons
Need Not Be In Writing - .35(e)(3)
Common Drinking Cups Must Not Be Used
Not Be Used - .51(A)(4)
See Video For List Of Acceptable Types Of Chipping Goggles
102
Does Employer Provide Protection?
Yes - .102(a)
Safety belt lanyard shall be ______ Nylon and withstand a Fall of No More Than ____ feet, breaking point ______ Lb.
1/2”, 6, 5400 - .104(d)
List Class B fire extingusher types -
Foam, Carbon Dioxide, Chemical - .150, TABLE F-1
A Fire Extinguisher not rated less than______Per _____ Sf of building area.
2A, 3000 - .150(c)
No more than ______ Gallons Of Flammable Liquids May Be Stored in a room Outside Of
Approved Storage Cabinets
25 - .152 b
Access Way ______Wide To Within ______ Feet Of Storage Containers
12’, 200, - .152 c (2)
Every container / vaporizor safety valve shall discharge not less than _____horizontally away from any opening to the building
5 feet - .153(d)(1)
Distance That Flammable Materials May Be Stored Away
From Liquified Petroleum Gas
0, 10,20,25 - .153(k) TABLE F-3
Flammable Materials Distance From Heating Device
.154(b)(2) TABLE F-4
Heating Devices At Least _______Away From Tarpaulins
Ten feet - .154(b)(4)
Materials stored in a building shall be At Least ______From Exterior Wall
Ten Feet - .250(b)(1)
Bagged materials shall _______ layers and cross key at least every ____ Bags High
step back, Ten - .250(b)(4)
Brick Stacks shall not be more than____ high, Loose brick tapered ______for every foot over 4 feet.
7’, 2 inches - .250(b)(6)
Masonry Block stacked over _____feet shall be taperd ______ per tier.
Six, 1/2 block .250(b)(7)
Lumber Stack Heights, not to exceed _______, no more than _____ if handled manually
20 feet, 16 feet - .250(b)(8)
Wire Rope Shall Not Be Used When More Than _____Of The Strands Have Been Damaged Within A Length Of ______.
10% , 8 Diameters - .251(c)(4)(iv)
Chute Required When Dropping Debris More Than ______Feet.
20 - .252(a)
When Debris Is Dropped Thru Holes In Floors, A _____ High Barricade _______Outside The Hole Must Be Installed Around The Drop Zone On The Lower Floor.
42”, 6” .252(b)
Skill Saws Are Required To Have ___________ Guards
“Point Of Operation” - .300(b)(4)
Compressed Air Used For Cleaning Purposes Shall Not Exceed ?
30 Psi - .302(b)(4)
Abrasion Wheel safety measures
Sufficient power, Safety guards, spindle end, nut and flange protection - 0.303
Gas Storage Requirements…….Gas Welding and cutting - Know the section
.350(a) & (d)
Welders Working In Confined Spaces…. 3 Requirements
Ventilation, Respirator, Safety line - .353(b)