2018 IBC Flashcards
Need Permit For Retaining Walls Greater Than____High
4’ - 4/105.2(4)
The Building Official May _______A Permit Issued In Error
Revoke - 5/105.6
Building Official May Issue Notice Of Violation for?
Violation of code or permit - 10/114.2
Hospital Occupancy Classification?
I-2 - 51/308.3
Fire Rating For 6 Story Building Elevator shaft ? Unless ______
2 Hour, Sprinklered - 59/403.2.1.2
Protect Columns ____Feet High with fire protective coating
5 - 125/704.9
The Substrate For Fireproofing Must Be At Least ___Degrees, for at least how long?
40, 24 hours - 126/704.13.4
Parapet Walls At Least ______ , above where?
30”, the roof surface and wall intersect - 130/705.11.1
Smoke Barriers Must Be At Least ____Inches Thick in group_____ Buildings
.1, I-3 - 135/709.3
Elevator Shafts More Than Four Stories Shall Have ____fire resistance
2 hour - 139
How many Layers Of 5/8” Drywall Produce 2 Hour Fire Rating?
2 - 166/TABLE 721.1(1)
Radiant Flux Must Be Not Less Than______For Group _____
Class I, I-2 - 214/804.4.2
Finish Flooring On Floor Sleepers is
Permitted - 215/805.1.2
Unlawful To Occupy Structure Without
Fire Protection - 217/901.5
Minimum Exterior Opening For Fire Fighter?
30” - 221/903.2.11.1.1
Sprinkler Deflector _____ max _____Below Deck constructed of wood joists
1” to 6”, 14” - 222/903.3.1.2.1
Kiosk Wider Than____Required A Sprinkler System
4’, 223/903.3.3
Electrical Control Unit For Backflow Valves
Shall be locked in open position - 224/903.4.1
Manual Control Lever near means of egress not less than____and not more than __ From Commercial Kitchen Exhaust System.
10’, 20’ - 226/904.12.1
Fire Cabinets Are Unlocked Except For Group?
I-3 - 229/905.7.2
Distance From Fire Extinguisher To Restaurant Exhaust Vent
30 Feet - 229/906.1(2)
Smoke Alarms Installed______From Cooking Appliance
Not less than 20 feet - 235/907.2.10.3
Smoke Alarms are located ________ From Bathroom Door
Not less than 3 feet - 235/907.2.10.4
Where Smoke Alarms Are Required, Smoke Alarms Shall
receive primary power from building electrical - 235/907.2.10.6
Location Of Fire Alarm Boxes located not more than _____From Exit
5 Feet - 238/907.4.2.1
Fire Alarm Boxes Maximum Height ____, Minimum Height______
48”, 42” - 238/907.4.2.2
Means Of Egress Ceiling Height Minimum
7’-6” - 257/1003.2
Maximum Floor Area Allowances Per Occupant
IBC
Emergency Power Illumination shall last____
90 Minutes on batteries or generator - 265/1008.3.4
Elevators Are Required In Building More Than ____ Stories above or below egress.
Four - 266/1009.2.1
Size of Wheel Chair Refuge Areas______, ______ per occupants.
30” X 48”, 200 - 267/1009.6.3
Areas of refuge are separated by?
Smoke barrier - 267/1009.6.4
Minimum Width Of Doors Is?
32” - 268/1010.1.1
Minimum Height Of Interior Door Is?
80” - 268/1010.1.1
The Exit Door Must Swing In Direction Of Egress When More Than_____m Occupants
50 Occupants - 269/1010.1.2.1
How many Pounds Pressure For Non Fire Interior Doors?
Five - 269/1010.1.3
Panic Hardware Required On Doors With Occupant Load Of More Than _____People
50 - 275/1010.1.10
Panic Hardware Unlatchable Force?
15 Pounds - 275/1010.1.10.1(4)