2018 IBC Flashcards
Need Permit For Retaining Walls Greater Than____High
4’ - 4/105.2(4)
The Building Official May _______A Permit Issued In Error
Revoke - 5/105.6
Building Official May Issue Notice Of Violation for?
Violation of code or permit - 10/114.2
Hospital Occupancy Classification?
I-2 - 51/308.3
Fire Rating For 6 Story Building Elevator shaft ? Unless ______
2 Hour, Sprinklered - 59/403.2.1.2
Protect Columns ____Feet High with fire protective coating
5 - 125/704.9
The Substrate For Fireproofing Must Be At Least ___Degrees, for at least how long?
40, 24 hours - 126/704.13.4
Parapet Walls At Least ______ , above where?
30”, the roof surface and wall intersect - 130/705.11.1
Smoke Barriers Must Be At Least ____Inches Thick in group_____ Buildings
.1, I-3 - 135/709.3
Elevator Shafts More Than Four Stories Shall Have ____fire resistance
2 hour - 139
How many Layers Of 5/8” Drywall Produce 2 Hour Fire Rating?
2 - 166/TABLE 721.1(1)
Radiant Flux Must Be Not Less Than______For Group _____
Class I, I-2 - 214/804.4.2
Finish Flooring On Floor Sleepers is
Permitted - 215/805.1.2
Unlawful To Occupy Structure Without
Fire Protection - 217/901.5
Minimum Exterior Opening For Fire Fighter?
30” - 221/903.2.11.1.1
Sprinkler Deflector _____ max _____Below Deck constructed of wood joists
1” to 6”, 14” - 222/903.3.1.2.1
Kiosk Wider Than____Required A Sprinkler System
4’, 223/903.3.3
Electrical Control Unit For Backflow Valves
Shall be locked in open position - 224/903.4.1
Manual Control Lever near means of egress not less than____and not more than __ From Commercial Kitchen Exhaust System.
10’, 20’ - 226/904.12.1
Fire Cabinets Are Unlocked Except For Group?
I-3 - 229/905.7.2
Distance From Fire Extinguisher To Restaurant Exhaust Vent
30 Feet - 229/906.1(2)
Smoke Alarms Installed______From Cooking Appliance
Not less than 20 feet - 235/907.2.10.3
Smoke Alarms are located ________ From Bathroom Door
Not less than 3 feet - 235/907.2.10.4
Where Smoke Alarms Are Required, Smoke Alarms Shall
receive primary power from building electrical - 235/907.2.10.6
Location Of Fire Alarm Boxes located not more than _____From Exit
5 Feet - 238/907.4.2.1
Fire Alarm Boxes Maximum Height ____, Minimum Height______
48”, 42” - 238/907.4.2.2
Means Of Egress Ceiling Height Minimum
7’-6” - 257/1003.2
Maximum Floor Area Allowances Per Occupant
IBC
Emergency Power Illumination shall last____
90 Minutes on batteries or generator - 265/1008.3.4
Elevators Are Required In Building More Than ____ Stories above or below egress.
Four - 266/1009.2.1
Size of Wheel Chair Refuge Areas______, ______ per occupants.
30” X 48”, 200 - 267/1009.6.3
Areas of refuge are separated by?
Smoke barrier - 267/1009.6.4
Minimum Width Of Doors Is?
32” - 268/1010.1.1
Minimum Height Of Interior Door Is?
80” - 268/1010.1.1
The Exit Door Must Swing In Direction Of Egress When More Than_____m Occupants
50 Occupants - 269/1010.1.2.1
How many Pounds Pressure For Non Fire Interior Doors?
Five - 269/1010.1.3
Panic Hardware Required On Doors With Occupant Load Of More Than _____People
50 - 275/1010.1.10
Panic Hardware Unlatchable Force?
15 Pounds - 275/1010.1.10.1(4)
Circular handrails min size____, Max____, Handrails Shall Extend ___ Past Top Riser
11/4”, 2”, 12” - 282/1014.3 & .6
Clear Space Between Handrail And Wall Is?
1 1/2” - 283/1014.7
Corridor Width 24” - 96”, Table #?
IBC
Emergency Escape and rescue Opening not greater Than_____Above Floor
44” - 302/1030.3
Number Of Accessible Parking Spaces Required
IBC
Free ventalation shal not be less than _____of area to be ventalated
1/150 - 321/1202.1
Openings into attic shall be?
Protected from small critters getting in - 321/1202.2.2
Stairwell illumination
at least 1 footcandle per tread - 324/1204.4
Fastener Spacing For Metal Siding
Not more than 24” vertical or horizontal - 334/1404.11.1
Minimum Lap for 12” siding
11/4” - 335/1404.16.2
Roofing
IBC
Metal Flashing At Wall And Roof Intersection Shall Be At Least_____Inches Thick
.019 - 341/1503.2.1
Type Shingle Most Fire Resistant______, Asphalt Shingle Roof Slopes ___or greater, 33% requires?
A, 17% , Two layers of underlayment - 345/1507.2.2
Valley Lining Material Thickness table
IBC
Wood Shingle And Shake Exposure Tables
IBC
Built up roofs shall have a slope of not less than_____
1/4:1 - 353/1507.10.1
Allowable Deflection Table
IBC
A Geotechnical Inspection Is Required When Backfilling More Than ____Under A Footing
12” - 430/1803.5.8
The Grade Away From A Building Must Be not less than ____For At Least_____
5% , 10’ - 431/1804.4
Dampproof shall extend from______ to above________
Footing, ground level - 433/1805.2.2
Top Of Drain At Least ____Above The Top Of The Footing, Filter Fabric Over Stone
6”, 433/1805.4.2
Table Presumptive Load-Bearing Values of soil
IBC
The Annular Space Around A Column Must Be At Least _____Larger Than The Diameter Of The Column
Four inches - 438/1807.3.3(1)
Specified Compressive Strength Table
IBC
The Minimum Depth Of Footings Below Grade Is ____
12” - 443/ 1809.4
The Flange Width Must Be At Least ____Of Depth Of H Pile
80% - 449/1810.3.5.3.1(1)
Minimum Slab ____, requires ____ poly vapor barrier, Lap of vaper barrier ____
31/2”, 6 Mil, 6” - 462/1907
Chimanys extend not less than ___above highest point and not less than ___where passes through roof.
2’, 3’ - 475/2113.9
What Is To Be Submitted By Engineer
Steel joist ans steel girder designations - 480/2207.2
Steel Joist Placement Plans Do or do Not Require The Seal Or Signature Of The Joist Manufactures’ Registered Engineer?
Do not - 480/2207.4
Steel Trusses Over 60’ Must Be
Designed By Engineer - 482/2211.1.3.2
Minimum Thickness Of Particle Board underlayment Is ___
1/4” - 484/2303.1.8.1
Information On Tag On Treated Lumber contains
quality mark of inspection agency - 484/2303.1.9.1
Panel Identification Index - 32/16 osb floor span is?
16” - 490/TABLE 2304.8(3)
Treated Wood Fasteners
Zinc coated, stainless steel, bronze or copper coated - 492/2304.10.5.1
Fastening Schedule
IBC
Keep Wood Joist _____And Girders _____ Above Grade
18”, 12” - 499/2304.12.1.1
Untreated Wood May Be Used Below Grade When
Below Ground Water Level or submerged in fresh water - 499/2304.3 EXC.
Sill Plate Anchor Bolts Located
not more than 12” or less than 4” From End And 6’ O.C. - 508/2308.3.1
Notching Of Floor Joist
notches on end not to exceed 25%, top or bottom 1/6th, holes no bigger than 2” - 509/2304.2
Floor Joist Spans
IBC
Maximum Spacing Of Perlins
4’ for 2x4, 6’ for 2x6 - 534/2308.7.7
Header Span Table
IBC
Rafters May Be Notched No More Than
1/4 Of The Depth - 533/2308.7.4
Skylights less than 45 degrees Should Be Mounted On A ____High Curb
4” - 557/2405.4
Glazing Within 24” Of An Operable Door Must Have A
Crossbar - 559/2406.4.2
Distance From Glazing To Stairs
Less than 60” is considered dangerous - 560/2406.4.6
Number Of Elevator Cars In A Hoistway
two hoistways for 4 elevators and no more than 4 elevators per hoistway - 591/3002.2
Time For Standby Power To Start After Power Failure -
60 Seconds - 592/3003.1.3
The Minimum Width Of Escalators Is
32” - 592/3004.2.2
No Plumbing Systems In Elevator
Equipment Rooms - 593/3005.6
Automatic Sprinklers Prohibited In.
Machine rooms, elevator machinery space, control rooms - 594/3007.2.1
Elevator Lobby For Fire Service Elevator, Minimum sqf _____Dimension Of not less than ___
150 Sqf, 8’ - 595/3007.6.4
Walkways Around Construction Sites Shall Be____Wide
4’ - 608/3306.2
When Public Enters Street To Go Around Project
Barriers of sufficient size to direct traffic are required - 608/3306.3
Barriers Around Construction Sites Shall Be ___ High
8’ - 608/3006.5
Protection Of Pedestrians
IBC
How many Days To Notify Neighbor Of Construction Next Door
Ten - 609/3307.1
American Iron and Steel Institute Covers
Design Of Cold Formed Steel - 613