OG 4.5 Respiratory Protection Equipment Flashcards
The SCBA is tested using a specified breathing machine with the breathing rate of what?
40 L per minute
A breathing rate of 40 L per minute represents what work rate for the average firefighter?
Moderate work rate based on minor’s work performance
A cylinder identified as 45 minutes Will normally last on average how many minutes?
Twenty two minutes
A cylinder identified as a 60 minute bottle Will normally last on average how many minutes?
30 minutes
EOSTI or low air alarm should activate at what percentage of the rated cylinder pressure?
25%
National average after activation of the low air alarm is how many minutes of air?
2 1/2 to 3 minutes of air
The SCBA should not be used beyond __ hours after initial exposure to chemical warfare agents?
Six hours
SCBA’s shall be worn how many minutes after extinguishment of fire?
45 minutes
SCBA shall be worn anytime carbon monoxide levels are above what?
35 ppm
SCBA’s will always be worn when oxygen levels are in what range?
19 1/2 percent or less
The cylinder is a composite cylinder, which consists of a _____ ______ liner fully wound with high-strength _____ _____ impregnated with ______ ______.
Seamless aluminum
Carbon fibers
Epoxy resin
Department of Transportation regulations require that carbon composite cylinders be hydrostatically tested how often?
Every five years
SCBA cylinders must be retired from service after the _____ year.
15th year
The circle numbers on the neck of the bottle indicate?
Month to be tested
The month and year are color-coded in what three colors on the bottle?
Red, green or black
Stealth H45 Bottle:
__ cubic ft.
____ liters
_____ weight empty
66 cubic ft.
1800 liters
10 lb. 9 oz. empty
Stealth H65 Bottle:
__ cubic ft.
____ liters
______ weight empty
88 cubic ft.
2400 liters
12 lb. 9 oz. empty
45 ft.³ of air weighs approximately?
4 1/2 pounds
The safety valve (burst disk) is a thin metal disc that will rupture at approximately ____ psig.
7500 psig.
The analog cylinder pressure gauge on the bottle is calibrated in ____ psig increments.
1000 psig
The audi alarm should activate between ____ psig and ____ psig and continue to ring until the pressure has dropped to ____ psig or less.
1200 psig
1050 psig
200 psig or less
What is the only alarm that will sound during low cylinder pressure?
Audi-alarm
The RIT connection is located within __ inches of the outside edge of the cylinder valve outlet.
4 inches
The RIT connection should only be used in what situation?
Rescue situations
First stage regulator will keep the pressure to the second stage regulator at approximately what psig?
80 psig
There is a pressure relief valve located on top of the first stage regulator at that will activated at approximately ___ psig?
125 psig
What type of regulator is the second stage regulator?
Pressure demand type that keeps positive pressure in the facepiece at all times.
Firehawk M7 control module has three control buttons, what color are they?
Yellow, white and green
The white alarm button which flashes green and red activates full pass alarm mode when pressed and held for how many seconds with or without pressure?
Three seconds
When the green mode button is pressed twice, This will cause the control module to toggle between what three things?
Digital display mode
Pressure remaining
Calculated service time remaining