NRCA Metal Panel and SPF Roof Systems, 2020 Flashcards
- One of the advantages of heavier gauge galvanized steel is that if thick enough, a panel will
not exhibit an objectionable amount of .
A. Oil canning
B. Surface defects
C. Glare
D. Rusting
- A 89
- According to NRCA, architectural metal panel roof systems perform well on slopes of
inch(es) or greater.
A. 14
B. 3
C. ½
D. 1/8
- B 96
- The height of a mechanical equipment stands supporting 12-inch-wide equipment is inches.
A. 14
B. 18
C. 24
D. 30
- A 152
- The nominal thickness of 16-ounce copper is inches.
A. .0270
B. .0216
C. .0418
D. .0340
- B 75
- Sixteen-ounce copper weighs per square foot.
A. 16 pounds
B. 16 ounces
C. 3/4 pounds
D. 14 ounces
- B 75
- During a reroof pipe penetrations require .
A. Same type of flashing regardless of use
B. Different methods of flashing
C. Stacks to have an unlimited height
D. None of the above
- B 192
- If unsatisfactory or questionable roof deck conditions are observed, the roofing contractor
should _______.
A. Install new roofing system over existing deck
B. Replace and repair damaged area of roof deck
C. Promptly inform the building owner or other responsible parties
D. Place tarp over the area and continue working in order to avoid wasting time
- C 417
- The is responsible for installing pipe support systems in reroofing.
A. Plumbing contractor
B. Mechanical contractor
C. Roofing contractor
D. At the discretion of the owner/property manager
- C 165
- Expansion joints be located in a roof assembly.
A. Expansion joints are never needed in a roof assembly
B. At the center of a commercial building
C. Every 12 feet
D. In the same location as the building’s structural expansion joint
- D 406
- Why would a recoat be needed for an SPF system?
A. Thin coat becoming slightly translucent
B. Extensive physical damage
C. Damage caused by hail, wind, or hurricane
D. All of the above
- D 401
- All stored materials should be stored according to .
A. International Building Code
B. Per NRCA guidelines
C. Within temperature range and guidelines required by the system manufacturer
D. All of the above
- C 380
- The standard time for testing and evaluating concrete’s compressive strength and its dryness or
suitability to be covered by a roofing system is days.
A. 7
B. 15
C. 30
D. 28
- D 359
- Metal panel roof systems are fabricated at .
A. Contractor’s facility or jobsite
B. Manufacturing facilities
C. Both A and B
D. None of the above
- C 104
- There are different commonly used sheet metal fasteners.
A. 8
B. 12
C. 13
D. 18
- C 159
- can be used as underlayment.
A. Asphalt felt
B. Synthetic sheets
C. Self-adhering polymer-modified bitumen sheets
D. All of the above
- D 115 – 116