NRCA Metal Panel and SPF Roof Systems, 2024 Flashcards
- One of the advantages of heavier gauge galvanized steel is that if thick enough, a panel will
not exhibit an objectionable amount of .
A. Oil canning
B. Surface defects
C. Glare
D. Rusting
- A 95 Metal Panel TC > Ch.4 Guidelines Applicable to Metal > 4.4 Oil Canning
- According to NRCA, architectural metal panel roof systems perform well on slopes of
inch(es) or greater.
A. 14
B. 3
C. ½
D. 1/8
- B 104 Metal Panel TC > Ch.6 Architectural Metal Panel Roof Systems > Intro
- The height of a mechanical equipment stands supporting 12-inch-wide equipment is inches.
A. 14
B. 18
C. 24
D. 30
- B 162 Metal Panel TC > Ch.7 > 7.8 Sheet Metal Flashing
- The nominal thickness of 16-ounce copper is inches.
A. .0270
B. .0216
C. .0418
D. .0340
- B 75 Metal Panel TC > Ch 4. Guidelines Applicable to Metal > 4.1 Metal Types
- Sixteen-ounce copper weighs per square foot.
A. 16 pounds
B. 16 ounces
C. 3/4 pounds
D. 14 ounces
- B 75 Metal Panel TC > Ch 4. Guidelines Applicable to Metal > 4.1 Metal Types
- During a reroof pipe penetrations require .
A. Same type of flashing regardless of use
B. Different methods of flashing
C. Stacks to have an unlimited height
D. None of the above
- B 202 Metal Panel TC > Ch.10 Reroofing > 10.6 Roof Replacement Guidelines for New
Metal Panel Roof Systems
- If unsatisfactory or questionable roof deck conditions are observed, the roofing contractor
should _____.
A. Install new roofing system over existing deck
B. Replace and repair damaged area of roof deck
C. Promptly inform the building owner or other responsible parties
D. Place tarp over the area and continue working in order to avoid wasting time
- C 461 Metal Panel TC > Ch 2. Structural Substrates > 2.1 Guidelines Applicable to All
Structural Substrates Types
- The is responsible for installing pipe support systems in reroofing.
A. Plumbing contractor
B. Mechanical contractor
C. Roofing contractor
D. At the discretion of the owner/property manager
- C 175 Metal Panel TC > Ch.9 Roof Accessories > 9.3 Pipe Support Systems
- Expansion joints be located in a roof assembly.
A. Expansion joints are never needed in a roof assembly
B. At the center of a commercial building
C. Every 12 feet
D. In the same location as the building’s structural expansion joint
- D 450 SPF TC > Ch.7 Roof Accessories > 7.2 Expansion Joints
- Why would a recoat be needed for an SPF system?
A. Thin coat becoming slightly translucent
B. Extensive physical damage
C. Damage caused by hail, wind, or hurricane
D. All of the above
- D 445 SPF TC > Ch.6 Protective Surfacings > 6.2 > Protective Coatings
- All stored materials should be stored according to .
A. International Building Code
B. Per NRCA guidelines
C. Within temperature range and guidelines required by the system manufacturer
D. All of the above
- C 424 SPF TC > Ch.5 Spray Polyurethane Foam > 5.1 Guidelines Applicable to All SPF
- The standard time for testing and evaluating concrete’s compressive strength and its dryness or
suitability to be covered by a roofing system is days.
A. 7
B. 15
C. 30
D. 28
- D 404 SPF TC > Ch.2 Roof Decks > 2.5 Structural Concrete
- Metal panel roof systems are fabricated at .
A. Contractor’s facility or jobsite
B. Manufacturing facilities
C. Both A and B
D. None of the above
- C 112 Metal Panel TC > Ch.5 Guidelines Applicable to All Metal Panel Roof Systems >
5.7 Manufacturing Methods
- There are different commonly used sheet metal fasteners.
A. 8
B. 12
C. 13
D. 18
- C 169 Metal Panel TC > Ch.8 Fasteners
- can be used as underlayment.
A. Asphalt felt
B. Synthetic sheets
C. Self-adhering polymer-modified bitumen sheets
D. All of the above
- D 125-126 Metal Panel TC > Ch.6 Architectural Metal Panel Roof Systems > 6.2
Underlayments