NASCLA - Additional Questions Flashcards
A ramp with 1:12 slope, will travel how far.
30 feet 09IBC 1010.4
30 Rooms in a motel, how many handicap spaces are required?
2 : 09 IBC 1106.1
What would be the min/max circle dimension in a bathroom for it to be handicap accessible?
60, ACC 304.3.1
Min/Max height of a fire alarm pull station.
42/48, 09IBC 907.4.2.2
20 Room Motel – How Many Fire Alarm Appliances Devices are Required?
2, 09IBC T 907.5.2.3.3
During which portion of a project would a Steel Joist Delivery most likely present a concern?
Last third ?
A Min/Max sidewalk width during construction:
4ft, 09IBC IBC 3306.2
When planning to control work site traffic, what should be considered?
Construction site itself, “Construction Jobsite Management” pg 154
A theater must have emergency standby power for how long?
90 min, 09IBC 1006.3
Which contract type best matches the progress payment to % of completion:
Cost Plus, “Construction Jobsite Management” pg 183
In estimating, to justify additional costs for security, all should be considered Except:
Ordering in large quantities to save on delivery costs, ?
If working outside near a 50KV power line, how far should you stay from the line?
10 Feet, OSHA 1926.1408 Power Line Safety Table (new) old ref 1926.550 (a)(15)(i)
A door jamb should be installed at what point?
After rough opening is built, “Carpentry” pg 618
If there’s a rough opening for a door, what should be installed first?
Jambs, “Carpentry” pg 618
Where there’s a wall, step flashing should be installed:
Under the shingles, Roofing Pg. 100