Misc 777 Flashcards
Min crew complement
777
10
Total pax
777
344
Total sky couch
777
20
Door Closed
FA check
777
No items in door frame
Push down on handle
RED Arrow continuous
Door Arming
777
Cover lever cover
Arming lever in the Red band
Yellow girt bar indicators
Disarming
777
Cover lever cover
Arming lever in Green band
Black girt bar indicators
Slide raft capacity
777
1&2 L&R
Cap 65
Overload 81
4 L&R
Cap 57
Overload 71
5 L&R
Cap 64
Overload 79
CSCP/CACP location
777
Door 1L CSCP
Door 2L CACP
Door 5R CACP
SATCOM location
777
1 at VCC
1 at 4R
Note - call F/D first to ask permission and connect
PA all cabin’s
46 + PTT
Direct access PA switch location
777 …. Check
1L
2L
4L
Sky couch restrictions
Max 4 seat mode
Max 3 couch mode
Inf 0-2 accompanied
2-14 behind or directly adjacent
Infant Pod pre-flight check
Req No. provided
Seal white- clean
Seal orange-used
Infant harness size’s
Sm 0-5kg <65cm
Med 5-10kg 65-85cm
Leg 10-18kg. 85-110cm
Check for infant harness kits
Req. No. provided
Pre ldg sky couch & pods
Wake 15min prior top
Leg rest stowed
Return pod and harness stowed with orange seal
Unserviceable - Red tag
Cabin log
Return to stowage
O2 flowing to mask 777 decompression
In-line flow indicator
Type of O2 system
777
Gaseous
How to turn off O2 system
Lift flap and replace pin
777
Mask deployment
Check about lights
13500
One LO/HI chime
Tape will play
Communicator announcement for fire fighting
“Attention flight attendant,would the ISM report to……area.”
At what angle is the BCF unusable
60degrees
Fly deck lithium fire PA
Flight attendant report to the flight deck immediately
Alternative evac command from F/D
Seatbelt sign on and off three times causing 6 chime’s
Emergency light duration
777
Check manual!!!
Approximately 20min
When emergency light button pushed
Check manual with regards to 777 vs 787
All lights illuminated inside and out
Opening an armed door illuminates emergency lights
Check manual 777 vs 787
At that door inside and out
Emergency light test switch is located at
1L and 5R
On approximately 1 min
Lights on outside illuminate what area
Base of slide
There are also slight lights
Flight deck indications of toilet smoke alarm
Caution alarm sounds
‘SMOKE LAVATORY’ EICAS msg
Cabin smoke indications toilet alarm
Check manual 777 vs 787
Smoke detector Red light
Smoke detector Alarm sounds
Amber call light flashes above toilet door
Nearest ACP Amber call light flashes
Nearest ACP continuous Hi chime
‘SMOKE DETECTED’ and location on CSCP and CACP
How to rest smoke indicators
Push Ambercall light
Push clear on CSCP or CACP
Red light stays illuminated until smoke has cleared
Scott/AVOX portable O2 bottle
Pre flight check
777
Min 1600psi
Mask and tubing attached to HI/outlet
Required No provided
Pre flight check Aisle chair
Secured
Serviceable
Pre flight check
Torch 777
Red light flashing every 3-4 seconds
777 Smoke hood
Pre flight check
Look through clear lid check inside
Check replace by date
Check green plastic seals
Both seals broken remove check indicator
Blue-serviceable
Pink-36hrs from discovery
Cabin log
Pax mask
777
Biz 3 outboard
5 inboard
PE 3 Outboard
5 inboard
23ab jk 4
30dg 3
Econ 3 outboard double seat
4 outboard triple seat’s
5 inboard quadruple seat
48abc 9 mask. 48hjk 7 mask
23defg 8 mask
35defg 8 mask
48defg 8 mask
2 for toilet and crew seat
777
OFAR smoke indications
Add indications from manual!!!
Ceiling horn
Alert horn
Detector alarm
Detector red light
Amber airflow off light
Area light
OFCR & OFAR smoke indications in the cabin
Check locations of HI chime!!!!
Amber light above door flashes
Nearest ACP flashes
Continuous HI chime
CSCP CACP alert msg
Reset smoke indications for overhead rest in the overhead rest
Check manual and add photos!!!
Check aircraft type
Push horn shutoff
Medical power outlet 777 and point location
9A - PSU
26A - Sidewall
36Abc - Sidewall between row 36 and 37
49Abc - Sidewall
58AB - Sidewall
Where is the escape hatch in OFAR
777
Under bunk 6
Alert Horn sounds 777 OFAR
Smoke - Pulsating
Decompression - Continuous
How to reset cabin smoke indications
Push Amber call light above rest door
777
How to reset Smoke Detection System when smoke has cleared Overhead rest plus warnings
Push Airflow/Smoke Reset button
Push for 2sec
Warning - don’t push until fire out and smoke cleared ( may allow smoke to enter the cabin)
Failure to reset may incur subsequent indications
Supply Airflow Off Light
Check and write ref page with regards to 5 Lo/Hi chimes
Amber when airflow off
Amber when below 25,000’
Amber when smoke detected
Amber when air supply valves turned off and exhaust valves open
Five LO/HI chime’s when airflow commanded closed
The alert horn in crew rest smoke vs decompression
Smoke - pulsating
Decompression - continuous
Chimes in OFAR for airflow off
5 LO/HI when commanded closed
Amber light on when below 25,000’
Water shutoff valve at 2L shuts off water supply
Check manual
Forward of 2L/R